Directory Search Results

Print List

#240504721

Range of direct fired water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.

Section:
1400 Heaters
Section Subtitle:
Gas fired, closed outlet. Heat retained in water heaters may cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to prevent excess pressure within the system.
WRAS Approval Number:
240504721
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Please refer to model.
Marking:
Lochinvar on body.
Installation Requirements:
R001 R140
Expiry date:
31/05/2029
Model:
LGC 160-210 CE LGC 200-210 CE LGC 160-350 CE LGC 200-350 CE LGC 245-420 CE LGC 285-420 CE LGC 245-560 CE LGC 285-560 CE LGC 380-560 CE WATER HEATERS

Approval Holder:
Lochinvar Ltd.
Company Name
Lochinvar Ltd.
Address
8 Lombard Way The MXL Centre Banbury
Postcode
OX16 4TJ
Country
Oxon
Phone
+44 (0) 1295 269981
General Email
general@lochinvar.ltd.uk

View All Listings by this Company

Print This Approval


#240704704

Range of wall mounted gas fired condensing instantaneous water heaters. Maximum working pressure 10.0bar. Maximum operating temperature 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240704704
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP(M) for 10-12L & 14~17L/min (Flow rate) ¾” BSP(M) for 22~26L/min (Flow rate)
Marking:
Company Logo Vanward, model, pressure, tempeture and and other technical info on adhesive label on side panel.
Installation Requirements:
R001
Expiry date:
31/07/2029
Model:
10~12L balance type & forces exhaust type gas water heater: JSG=balance type gas water heater, JSQ=forces exhaust type gas water, a= nominal heat input(kW) (fixed from 20, 22 to 24), b=volume (fixed from 10, 11 to 12), STc=Sd= the type of casing (c fixed from 27, 28 to 29, d fixed from 21, 25, 22, 21B, 23, 24, 25(A), 25(B), 26, 27, 28, 31, 32, 34 to 35) Casing 1: ST27, S21, Casing 2: ST28, S25, Casing 3: ST29, S22, Casing 4: S21B, Casing 5: S23, Casing 6: S24, Casing 7: S25(A), Casing 8: S25(B), Casing 9: S26, Casing 10: S27, Casing 11: S28, Casing 12: S31, Casing 13: S32, Casing 14: S34, Casing 15: S35. Where a typical code is: ①JSG28-14ST28、JSG14ST-S25: JSG=balance type gas water heater 28=nominal heat input(kW) 14=volume ST28=the type of casing, ST=structure platform S25=the type of casing 14~17L balance type & forces exhaust type gas water heater: JSG=balance type gas water heater, JSQ=forces exhaust type gas water, a= nominal heat input(kW) (fixed from 20, 22 to 24), b=volume (fixed from 10, 11 to 12), STc=Sd= the type of casing (c fixed from 27, 28 to 29, d fixed from 21, 25, 22, 21B, 23, 24, 25(A), 25(B), 27, 28, 31, 32, 34 to 35). Same casings as above but without casing 9. ②JSG14ST-S25(B) 、JSQ28-14ST28 JSG=balance type gas water heater JSQ=forces exhaust type gas water 14=volume 28=nominal heat input(kW) ST=structure platform S25(B)=the type of casing, ST28=the type of casing 22~26L outdoor type gas water heater: JSW=outdoor type gas water heater, a= nominal heat input(kW) (fixed from 44 to 52), b=volume (fixed from 22 to 26), ST58=Wd= the type of casing (d fixed from 81, 82, 83 to 84), Casing 1: ST58, W81, Casing 2: W82, Casing 3: W83, Casing 4: W84. ③JSW44-22ST58、 JSW22HT-W81: JSW=outdoor type gas water heater 44=nominal heat input(kW) 22=volume ST58=the type of casing, HT=structure platform W81=the type of casing
JSG20-10ST27, JSG10ST-S21, JSQ20-10ST27, JSQ10ST-S21, JSG22-11ST27, JSG11ST-S21, JSQ22-11ST27, JSQ11ST-S21, JSG24-12ST27, JSG12ST-S21, JSQ24-12ST27, JSQ12ST-S21, JSG20-10ST28, JSG10ST-S25, JSQ20-10ST28, JSQ10ST-S25, JSG22-11ST28, JSG11ST-S25, JSQ22-11ST28, JSQ11ST-S25, JSG24-12ST28, JSG12ST-S25, JSQ24-12ST28, JSQ12ST-S25, JSG20-10ST29, JSG10ST-S22, JSQ20-10ST29, JSQ10ST-S22, JSG22-11ST29, JSG11ST-S22, JSQ22-11ST29, JSQ11ST-S22, JSG24-12ST29, JSG12ST-S22, JSQ24-12ST29, JSQ12ST-S22, JSG10ST-S21B, JSQ10ST-S21B, JSG11ST-S21B, JSQ11ST-S21B, JSG12ST-S21B, JSQ12ST-S21B, JSG10ST-S23, JSQ10ST-S23, JSG11ST-S23, JSQ11ST-S23, JSG12ST-S23, JSQ12ST-S23, JSG10ST-S24, JSQ10ST-S24, JSG11ST-S24, JSQ11ST-S24, JSG12ST-S24, JSQ12ST-S24, JSG10ST-S25(A), JSQ10ST-S25(A), JSG11ST-S25(A), JSQ11ST-S25(A), JSG12ST-S25(A), JSQ12ST-S25(A), JSG10ST-S25(B), JSQ10ST-S25(B), JSG11ST-S25(B), JSQ11ST-S25(B), JSG12ST-S25(B), JSQ12ST-S25(B), JSG10ST-S26, JSQ10ST-S26, JSG12ST-S26, JSQ12ST-S26, JSG10ST-S27, JSQ10ST-S27, JSG12ST-S27, JSQ12ST-S27, JSG10ST-S28, JSQ10ST-S28, JSG12ST-S28, JSQ12ST-S28, JSG10ST-S31, JSQ10ST-S31, JSG12ST-S31, JSQ12ST-S31, JSG10ST-S32, JSQ10ST-S32, JSG12ST-S32, JSQ12ST-S32, JSG10ST-S34, JSQ10ST-S34, JSG12ST-S34, JSQ12ST-S34, JSG10ST-S35, JSQ10ST-S35, JSG11ST-S35, JSQ11ST-S35, JSG12ST-S35, JSQ12ST-S35. JSG28-14ST27, JSG14ST-S21, JSQ28-14ST27, JSQ14ST-S21, JSG30-16ST27, JSG16ST-S21, JSQ30-16ST27, JSQ16ST-S21, JSG31-17ST27, JSG17ST-S21, JSQ31-17ST27, JSQ17ST-S21, JSG28-14ST28, JSG14ST-S25, JSQ28-14ST28, JSQ14ST-S25, JSG30-16ST28, JSG16ST-S25, JSQ30-16ST28, JSQ16ST-S25, JSG31-17ST28, JSG17ST-S25, JSQ31-17ST28, JSQ17ST-S25, JSG28-14ST29, JSG14ST-S22, JSQ28-14ST29, JSQ14ST-S22, JSG30-16ST29, JSG16ST-S22, JSQ30-16ST29, JSQ16ST-S22, JSG31-17ST29, JSG17ST-S22, JSQ31-17ST29, JSQ17ST-S22, JSG14ST-S21B, JSQ14ST-S21B, JSG16ST-S21B, JSQ16ST-S21B, JSG17ST-S21B, JSQ17ST-S21B, JSG14ST-S23, JSQ14ST-S23, JSG16ST-S23, JSQ16ST-S23, JSG17ST-S23, JSQ17ST-S23, JSG14ST-S24, JSQ14ST-S24, JSG16ST-S24, JSQ16ST-S24, JSG17ST-S24, JSQ17ST-S24, JSG14ST-S25(A), JSQ14ST-S25(A), JSG16ST-S25(A), JSQ16ST-S25(A), JSG17ST-S25(A), JSQ17ST-S25(A), JSG14ST-S25(B), JSQ14ST-S25(B), JSG16ST-S25(B), JSQ16ST-S25(B), JSG17ST-S25(B), JSQ17ST-S25(B), JSG14ST-S27, JSQ14ST-S27, JSG16ST-S27, JSQ16ST-S27, JSG14ST-S28, JSQ14ST-S28, JSG16ST-S28, JSQ16ST-S28, JSG14ST-S31, JSQ14ST-S31, JSG16ST-S31, JSQ16ST-S31, JSG14ST-S32, JSQ14ST-S32, JSG16ST-S32, JSQ16ST-S32, JSG14ST-S34, JSQ14ST-S34, JSG16ST-S34, JSQ16ST-S34, JSG14ST-S35, JSQ14ST-S35,JSG16ST-S35, JSQ16ST-S35. JSW44-22ST58, JSW22HT-W81, JSW52-26ST58, JSW26HT-W81, JSW22HT-W82, JSW26HT-W82, JSW22HT-W83, JSW26HT-W83, JSW22HT-W84, JSW26HT-W84.

Approval Holder:
Guangdong Vanward New Electric Co. Ltd.
Company Name
Guangdong Vanward New Electric Co. Ltd.
Address
13 Jianye Mid- Road Shunde High Tech Industry Development Zone
Country
Ronggui Shunde

View All Listings by this Company
Manufacturer:
Guangdong Vanward New Electric Co. Ltd.
Company Name
Guangdong Vanward New Electric Co. Ltd.
Address
13 Jianye Mid- Road Shunde High Tech Industry Development Zone
Country
Ronggui Shunde

View All Listings by this Company

Print This Approval


#240902039

Range of VEGAPULS radar sensors for level measurement with plastic bodies. Cold water use only. Open outlet use only.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See model key
Marking:
VEGA logo date of manufacturer (YYYY), serial number and other technical data on body
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
PSC21.ab-c-d-N-f-g-h-I VEGAPULS C 21 PSC22.ab-c-d- N -f-g-h-I VEGAPULS C 22 PSC23.ab-c-d- N -f-g-h-I VEGAPULS C 23 PS21.ab-c-d- N -f-g-h-I VEGAPULS 21 PS31.ab-c-d- N -f-g-h-I VEGAPULS 31 KEY FOR VEGAPULS C 21 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; G Thread G1½ / G1 N Thread 1½NPT / 1NPT R Thread R1½ / R1 g = Cable material / Length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 22 ab = Explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignition proof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as: X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 23 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; F Thread G1 M Thread 1NPT Q Thread R1 g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS 21 / 31 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) AX without, for Ex-free area (CE, UKCA, RCM) VC ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) SC EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 TC CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 WC INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 c = Approved as overfill protection, which can be displayed as; X Without W With (WHG, VLAREM) d = Ship approval, which can be displayed as; X Without S With (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff/Pharmaceutical certificate, which can be displayed as X Without N With (NSF/ANSI/CAN 61) P With (NIH) F With (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable entry / connection, which can be displayed as; M M20x1.5 / Cable gland PA black (ø5-9mm), standard h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART i = Sensor setting via smartphone and VEGA Tools app X Without B With

Approval Holder:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company
Manufacturer:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company

Print This Approval


#240704008

Concealed, floor mounted basic set with DZR brass body. For use with floor standing combination tap assemblies. Maximum operating pressure 10 bar. Maximum operating temperature 70°C

Section:
1535 Miscellaneous
Section Subtitle:
Tap accessories.
WRAS Approval Number:
240704008
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (F)
Marking:
Hansgrohe & DR
Installation Requirements:
R001 R010
Expiry date:
31/07/2029
Model:
10452180

Approval Holder:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company
Manufacturer:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company

Print This Approval


#240206701

Range of horizontal or vertical multi-stage pumps with a stainless-steel body (HM models) or cast iron body with blue coloured cationic resin coating (VM models), incorporating either plastic or stainless-steel impellers (see model), stainless steel sleeve, EPDM gaskets and seals. Maximum working pressure 10.0 bar / 16.0 bar (see models). Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240206701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
HM models: 1” - 2” BSP (F) VM models: 1¼” - 1½” BSP (F).
Marking:
Lowara or Goulds Water Technology (both brands of Xylem), manufacturer and address, model number, serial number, maximum working pressure and technical information on adhesive label on body.
Installation Requirements:
R001 R415
Expiry date:
28/02/2029
Model:
1HM, 3HM, 5HM, 10HM, 15HM & 22HM. 1VM, 3VM, 5VM & 10VM. Model nomenclature: W XXX YY Z EM Where: W - flow rate (m3/h), either 1, 3, 5, 10, 15, or 22. XXX - Model type: Horizontal (HM) or Vertical (VM) mode, where last (optional) digit can denote the variable speed drive as follows: Null = standard asynchronous motor, H = equipped with Hydrovar, X = other drives, E = e-SM. YY - Number of impellers/stages HM models: 2-25 stages only (02-25), VM models: 2-8 stages only (02-08). Z - Material, where: (P) is plastic impeller and SS AISI 304 body (HM & VM models), (S) is SS AISI 304 impeller and body (HM models only), (N) is SS AISI 316 impeller and body (HM models only). E = 5 - 6 digits for electrical specification. M = 3 digits, where: 1st digit: Mech. rotary seal - V = Aluminium oxide (Ceramic), or Mech. rotary seal - Q = Silicon carbide (Ceramic). 2nd digit: Mech. stationary seal - B = Carbon resin impregnated. 3rd digit: Mech. seal elastomers - E = EPDM. Example code: 1HM03P05M5HVBE. Max Working Pressure for VM models → 10 bar. Max Working Pressure for HM models with stainless steel impellers and QBE Mechanical Seal → 16 bar (Depending on number of stages - see below), Max Working Pressure for HM models with plastic impellers and/or VBE Mechanical Seal → 10 bar (Depending on number of stages - see below). 1HM (P)/(S)/(N) 1-16 stages - 10.0 bar, 1HM (S)/(N) 18-25 stages - 16.0 bar. 3HM (P)/(S)/(N) 1-13 stages - 10.0 bar, 3HM (S)/(N) 14-21 stages - 16.0 bar. 5HM (P)/(S)/(N) 1-13 stages - 10.0 bar, 5HM (S)/(N) 14-21 stages - 16.0 bar. 10HM (P)/(S)/(N) 1-8 stages - 10.0 bar, 10HM (S)/(N) 9-13 stages - 16.0 bar. 15HM (S)/(N) 2-7 stages - 10.0 bar, 22HM (S)/(N) 2-5 stages - 10.0 bar.

Approval Holder:
Xylem Service Italia S.r.l
Company Name
Xylem Service Italia S.r.l
Address
Via Vittorio Lombardi 14, 36075 Montecchio Maggiore-Alte Ceccato VI, Vicenza
Country
Italy
Phone
0039 0444 707111

View All Listings by this Company
Manufacturer:
Lowara S.r.l | Xylem Service Italia S.r.l | Xylem Manufacturing Middle East Region FZCO Dubai | Xylem Water Systems International Philippines Inc.
Company Name
Lowara S.r.l | Xylem Service Italia S.r.l | Xylem Manufacturing Middle East Region FZCO Dubai | Xylem Water Systems International Philippines Inc.
Address

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 505 of 640

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.