Range of concealed and exposed two-way diverters, (brass bodies – various finishes, trim sets and operating members). The inlets on XX1650YY and XX1721YY models incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C (PSA019 YY, PSA020 YY & XX1782YY) Maximum operating temperature 60°C (PSH049, XX1650YY, RZ/1721 & XX1721YY).
Range of pre-set pressure relief valves with a DZR brass body, incorporating an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Compression connection for use with copper tube to BS EN 1057. Maximum working pressure: see models. Maximum operating temperature: 23.0°C
Range of cold-water inlet control groups consisting of an in-line, manually adjustable pressure reducing valve and a pressure relief valve pre-set at either 6.0 or 8.0 bar, housed within DZR brass bodies. The products incorporate approved check valve cartridges; however, the complete products have not been fully tested to demonstrate they provide backflow protection. The pressure reducing valves also have stainless-steel strainers. Maximum inlet pressure 16.0 bar. Cold water use only. CWIC351300 – Outlet pressure range 1.0 to 3.5 bar. Pressure relief valve set at 6.0 bar CWIC351301 – Outlet pressure range 1.0 to 2.1 bar. Pressure relief valve set at 8.0 bar. CWIC351303 – Outlet pressure range 1.0 to 3.5 bar. Pressure relief valve set at 8.0 bar CWIC351306 – Outlet pressure range 1.5 to 6.0 bar. Pressure relief valve set at 8.0 bar
Inlet control group with a DZR brass body, consisting of a pressure reducing valve and pressure relief valve (6.0 Bar). The inlet incorporates a stainless-steel strainer, and the outlet incorporates an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The product is for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C. Outlet pressure range of the pressure reducing valve is 1.0 to 4.0 bar.
In-line polyphosphate scale inhibitor. The product is supplied with a single check valve cartridge in the inlet connection, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 5.0 bar. Cold water use only.
Page 462 of 559
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.