Inlet hose consisting of a EPDM inner hose layer and corrugated outer cover. The hose is fitted with an integral device consisting of a water sensitive material which expands when in contact with water. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of stainless steel or nylon braided EPDM lined flexible hose assemblies with various brass end connections. Compression connection to be used with copper pipe EN1057. Maximum working pressure 10 Bar. Maximum operating temperature 70°C.
Nylon and stainless-steel braided EPDM lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of stainless steel braided hoses with EPDM liner and NBR or fibre gaskets. DN13 and DN19 Maximum working pressure 10 bar. Maximum operating temperature 65°C. DN25 Maximum working pressure 10 bar. Cold water use only.
Range of stainless-steel braided EPDM lined flexible hose assemblies with various end connections. SCFA models incorporate a spherical valve. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of multi-layer shower hoses with a PVC inner hose, supplied with EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of stainless steel or brass double interlocking, TPS lined flexible hose assemblies (various finishes) incorporating EPDM gaskets. Maximum operating temperature 60°C. Open Outlet Use Only
Range of stainless steel or brass double interlocking, TPS lined flexible hose assemblies (various finishes) incorporating EPDM gaskets. Maximum operating temperature 60°C. Open Outlet Use Only
Range of stainless-steel expansion joints with flanged or threaded end connections. For maximum working pressure please refer to model. Maximum operating temperature 100°C.
Range of wall mounted thermostatic bar shower mixers with brass bodies, incorporating a thermostatic cartridge controlling the temperature and non-rising spindle headwork controlling the flow. The inlets incorporate stainless steel strainers and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Exposed wall mounted bar shower mixer (chrome plated brass body), incorporating a two-way ceramic disc diverter headwork controlling the flow with a cubed type operating member. Temperature is controlled independently via a thermostatic cartridge with a cubed type member that incorporates a manual override button. The inlets incorporate flow regulators, plastic strainers and approved single check valve cartridges (however, the complete product has not been fully tested to demonstrate that it provides backflow protection). The product is supplied with a shower handset, shower hose, overhead shower and a riser rail assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, thermostatic bar shower mixers (brass bodies – various finishes), incorporating a quarter turn ceramic disc headwork that controls the flow with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge with dome type operating member that incorporates a manual override button. Models 801524.001 & 801540.001 incorporate a half turn ceramic disc headwork that diverts the flow to an overhead shower or shower handset. Both inlets incorporate an approved check valve cartridge and stainless steel strainers however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models 801508.001 & 801508.002. Maximum working pressure 10 bar. Maximum operating temperature 65 C. Model 801509.001. Maximum working pressure 10 bar. Maximum operating temperature 60 C. Model 801524.001. Maximum working pressure 5 bar. Maximum operating temperature 60 C. Model 801540.001. Maximum working pressure 5 bar. Maximum operating temperature 65 C.
Series of wall mounted, thermostatic mixer valve with brass bodies, diverter headwork that controls flow between one, two or three outlets (see model) with various type of operating member. The temperature is controlled independently via a thermostatic cartridge operating member with a manual override button. Inlets incorporate a stainless-steel strainer and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 55°C
Wall mounted, exposed shower valve which has a brass body, available in different finishes. Flow is controlled by a quarter turn ceramic disc headwork with dome operating member and temperature is controlled independently via a thermostatic cartridge with dome type operating member. The inlets incorporate a single check valve cartridge however, the complete assembly has not been fully tested to demonstrate that it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of butterfly valves with blue epoxy coated, ductile iron bodies and handwheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of butterfly valves with ductile iron bodies (blue epoxy coating), stainless steel disc and EPDM seat. The valves are operated by a lever mechanism. Maximum working pressure 20.0 bar. Cold water use only.
Range of two or five way diverter cartridges with plastic bodies. For insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Two-way ceramic disc diverter with a plastic body, incorporating a press on-off function. For insertion into specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Two-way ceramic disc diverter headwork (2 on, 1 off) with a plastic body and silicone seals. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of ‘901’ float operated equilibrium inlet valves incorporating brass bodies and float arms. Maximum working pressure - See Models Maximum operating temperature – Cold water use only.
Page 444 of 566
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.