'5594610'. Black coloured, compression moulded EPDM material. Shore hardness 60. Tested in-radius size 1.0mm. For use with water up to 85°C.
'FKM 90 Black 6019020105-CMP00700'. Black coloured, compression moulded FKM material. Shore hardness 90. Tested in-radius size 1.1mm. For use with water up to 85°C.
‘Loctite® 55’. White coloured nylon cord coated with a silicone paste, intended for use as a thread sealant. The cord is to be applied and tightened in accordance with Technical Data Sheet ‘reference 1.9’, dated August 2016 and this material is only approved for these conditions. For use with water up to 85°C.
Range of single hole, single outlet (fixed) electronically controlled combination tap assemblies (various finishes). Flow is controlled by a solenoid valve activated by via an infra-red sensor and the temperature set via a manual lever. The inlet adaptor to the hoses incorporates a check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2 or 3) with a built-in strainer, and the outlet incorporates an aerator. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of single hole, single outlet, electronically controlled tap assemblies (chrome plated brass body). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Supplied with a stainless steel braided PEX lined flexible connection hose and a manual lever for controlling the temperature. Maximum working pressure 8.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of single hole, single outlet (fixed) combination tap assemblies (chrome plated – brass bodies). Flow is controlled via a solenoid which is actuated via an infrared sensor and the temperature is controlled by a manual lever. The spout outlets incorporate plastic aerators. The inlet hoses incorporate stainless steel strainers and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of single hole, single outlet, electronically controlled tap assemblies (brass body – various finishes). The flow is controlled via a solenoid valve and activated by an infra-red sensor on the front of the spout. The spout outlet incorporates a plastic aerator. Models xxx.yyy.170E/W are supplied with a click clack waste. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
WC flushing cistern incorporating a side entry BS 1212-4 compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a bottom entry BS 1212 - 4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar, cold water use only.
Range of ceramic cartridge headworks with plastic bodies, for insertion into specifically dimensioned bores. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 70°C
Page 435 of 1011
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.