Range of crimp fittings with a bronze body incorporating EPDM O-rings. For use with copper pipe manufactured to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of capillary end feed bronze fittings for use with copper tube (manufactured to BS EN 1057). 15mm – 54mm fittings have a maximum working pressure of 25.0 bar. 67mm – 108mm fittings have a maximum working pressure of 16.0 bar. Maximum operating temperature 100°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Copper heat transformer. Maximum working pressure 11.0 bar. Maximum operating temperature 95°C.
Range of domestic hot water units incorporating instantaneous or semi-instantaneous plate heat exchanger assemblies. The product incorporates a motorised control valve, managed primary and secondary pumps (see model), and a drain valve on both circuits. Maximum working pressures: 10.0 bar primary, 9.5 bar secondary. Maximum operating temperatures: 110°C primary, 85°C secondary.
Range of unvented electric storage water heaters consisting of a mild steel, glass/enamel coated tank, heating element and pressure relief valve set at 6.0 bar. Maximum working pressure 5.5 bar. Maximum operating temperature 75°C.
Ranges of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. Products are supplied with a rigid filling loop or keyless filling link. Maximum working pressure of the primary circuit is 2.5 bar & maximum supply pressure of the secondary circuit is 8.0 bar. Cold water supply only. Maximum operating temperature 95°C.
Q4000 range of water meters incorporating stainless steel bodies, FKM rubber gasket and grey epoxy resin liner. Maximum working pressure 16.0 bar. Cold water use only.
H4000 range of helical rotor bulk water meters, with blue epoxy coated cast iron bodies and NBR ‘O’-rings. Maximum working pressure 16.0 Bar. Cold water use only.
Range of flow meters incorporating black epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of 2,3 or 4 way manifolds incorporating a nickel plated brass body with non-rising spindle stop valves. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of shower outlet elbows with brass bodies (chrome plated,with exception of model 27.076.LS0). Some models incorporate a shower handset holder. The outlet incorporates a check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of in-line flow sensors with a plastic body, turbine and impeller case. Maximum working pressure 25.0 bar. Cold water use only.
Range of compact wall outlet assemblies with plastic bodies (chromium plated) and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. Maximum operating temperature 55°C.
Screw down elbow servicing valve with brass body (brushed chrome) which is intended to connect to an appliance, e.g. washing machine, dishwasher to the water supply. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of threaded fittings with either plain brass, nickel plated brass or chrome plated brass bodies. Maximum operating pressure 16.0 bar. Maximum operating temperature 99°C.
Concealed wall insulation unit with a brass body and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Range of isolation valves with a brass body (various surface finishes - see model) and either a quarter turn ceramic disc (PEX-230-C/P and PEX-231-C/P models) or a non-rising spindle (all other models) with various operating members (see model) and NBR ‘O’-rings. The inlet of the PEX-230-C/P and PEX-231-C/P models incorporates a stainless-steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of inline circulating pumps with bronze bodies, plastic impeller and EPDM rubber seals. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of booster pumps with plastic bodies and impellers, EPDM ‘O’-rings and stainless steel inlet manifolds. The product incorporates a non-return valve. The ESYBOX MAX single models are also supplied with an optional 2” BSP (M) x 1¼” BSP (F) plastic inlet adaptor. Maximum working pressure 12.0 bar. Cold water use only.
Page 37 of 427
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.