Directory Search Results

Print List

#2012365

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
Size:
¾” BSP (M)
Marking:
BAXI ON FRONT OF CASING. BAXI, address, serial number, technical & pressure information on label inside case.
Installation Requirements:
R001
Expiry date:
31/12/2025
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
BAXI ASSURE HIMAX TWIN ID 90/30 ELECTRONICALLY CONTROLLED HEAT INTERFACE UNITS

Approval Holder:
Baxi Heating UK Limited
Company Name
Baxi Heating UK Limited
Address
Brooks House, Coventry Road, Warwick
Postcode
CV34 3LL

View All Listings by this Company

Print This Approval


#2107319

Range of vertical vented cased copper cylinders with indirect coils. The secondary circuit incorporates a thermostatic mixing valve. The inlet consists of a ball valve with strainer, inline non verifiable single check valve and mini shock arrestor. Cylinder are supplied with a factory fitted immersion heater. Maximum working pressure - secondary 6.0 bar, primary 2.2 bar. Maximum operating temperature - secondary is 60°C, primary 85°C

Section:
1390 Heaters
Section Subtitle:
Electric, thermal storage, mains fed, open outlet.
WRAS Approval Number:
2107319
Size:
22mm compression (secondary) 1” BSP (F) primary
Marking:
Copper Industries, model name, model size, safety markings, manufacturers contact details, Maxi Pod, date of manufacture (DD/MM/YY) and ID no on body.
Installation Requirements:
R001
Expiry date:
31/07/2026
Model:
Maxi Pod 210 Maxi Pod 250 Maxi Pod 300
Product Images

Approval Holder:
Copper Industries Ltd
Company Name
Copper Industries Ltd
Address
Toome Business Park 21 Hillhead Road Toome Co Antrim
Postcode
BT41 3SF
Country
United Kingdom
Phone
02879 659736
General Email
mail@copperindustries.co.uk

View All Listings by this Company
Manufacturer:
Copper Industries Ltd
Company Name
Copper Industries Ltd
Address
Toome Business Park 21 Hillhead Road Toome Co Antrim
Postcode
BT41 3SF
Country
United Kingdom
Phone
02879 659736
General Email
mail@copperindustries.co.uk

View All Listings by this Company

Print This Approval


#2101337

Range of ice making machines which incorporate a solenoid valve to control the flow. Maximum working pressure 5.0 bar. Cold water use only.

Section:
1500 Ice Making Machines
Size:
¾” BSP Captive nut.
Marking:
Model, date of production (YYMM) and other technical information on rear panel. Simag on front of machine.
Installation Requirements:
R001 R009 R150 R171 R511
Expiry date:
31/01/2026
Model:
SIMAG SDE 18, 24, 30, 34, 40, 50, 64, 84, 100, 170 & 220. SIMAG SDH 18, 24, 30, 40, 50 & 64.
Product Images

Approval Holder:
Scotsman Ice S.r.l.
Company Name
Scotsman Ice S.r.l.
Address
Via Lainate 31, 20010 Pogliano Milanese (MI)
Country
Italy

View All Listings by this Company
Manufacturer:
Scotsman Ice S.r.l.
Company Name
Scotsman Ice S.r.l.
Address
Via Lainate 31, 20010 Pogliano Milanese (MI)
Country
Italy

View All Listings by this Company

Print This Approval


#2101055

Range of commercial ice making machines which incorporate a solenoid valve controlling the flow. Maximum working pressure 7.8 bar. Cold water use only.

Section:
1500 Ice Making Machines
Size:
PVC lined flexible hose assembly with ¾” BSP captive nut end connections.
Marking:
Hoshizaki on front panel & door. Hoshizaki, model & operating info on adhesive label on side.
Installation Requirements:
R001 R150 R511
Expiry date:
31/01/2026
Model:
IM-21CNE-HC IM-30CNE-HC IM-30CNE-HC-25 IM-45NE-HC IM-45NE-HC-25 IM-45CNE-HC IM-45CNE-HC-25 IM-65NE-HC IM-65NE-HC-25 DIM-40DE-HC
Product Images

Approval Holder:
Hoshizaki Europe Ltd
Company Name
Hoshizaki Europe Ltd
Address
Telford 70 Stafford Park 7 Telford
Postcode
TF3 3BQ
Country
Shropshire

View All Listings by this Company
Manufacturer:
Hoshizaki Europe Ltd
Company Name
Hoshizaki Europe Ltd
Address
Telford 70 Stafford Park 7 Telford
Postcode
TF3 3BQ
Country
Shropshire

View All Listings by this Company

Print This Approval


#2103010

Range of rotating piston, volumetric in-line water meters with brass bodies. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1505 Water Meters
Size:
¾” BSP - 2” BSP (M) inlet and outlet.
Marking:
Elster on lid. Elster and technical information on body.
Installation Requirements:
R001
Expiry date:
31/03/2026
Model:
V100 - DN15, 20, 25, 30 & 40
Product Images

Approval Holder:
Elster Water Metering Limited
Company Name
Elster Water Metering Limited
Address
130 Camford Way Sundon Park Luton
Postcode
LU3 3AN
Country
United Kingdom
Phone
01582 846 400
General Email
matthew.ward@honeywell.com

View All Listings by this Company
Manufacturer:
Elster Water Metering Limited
Company Name
Elster Water Metering Limited
Address
130 Camford Way Sundon Park Luton
Postcode
LU3 3AN
Country
United Kingdom
Phone
01582 846 400
General Email
matthew.ward@honeywell.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 35 of 430

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.