Range of deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a half-turn ceramic disc headwork, both controlling the flow and manually diverting the flow to a shower outlet connection. Temperature is controlled independently via a thermostatic cartridge. The spout outlet incorporates a plastic aerator. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and a manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. Products are supplied with a shower hose and handset and plastic backnuts. Maximum working pressure 6.0 Bar.
Range of deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a half-turn ceramic disc headwork, both controlling the flow and manually diverting the flow to a shower outlet connection. Temperature is controlled independently via a thermostatic cartridge. The spout outlet incorporates a plastic aerator. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Range of deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a half-turn ceramic disc headwork, both controlling the flow and manually diverting the flow to a shower outlet connection. Temperature is controlled independently via a thermostatic cartridge. The spout outlet incorporates a plastic aerator. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies), incorporating a quarter turn ceramic disc headworks with dome type operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a dome type operating member and a manual override button. The inlets incorporate stainless steel strainer washers, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a manual diverter to shower outlet and a plastic flow straightener. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating ceramic disk headworks with single lever operating members and self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener and product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet, fixed combination tap assembles (chrome plated brass bodies). Incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to a shower outlet. The spout outlets incorporate plastic aerators or flow straightener and supplied with metal backnuts. The products are supplied with a shower hose and handset. Maximum working pressure 10 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Deck mounted, two hole, single outlet fixed combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator and the products are supplied with metal backnuts, shower hose and handset. The shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum Working Pressure 10.0 bar. Maximum operating temperature 60°C
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge incorporating a dome type operating member and a manual override button. Each inlet incorporates a combined NBR washer and stainless steel strainer, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a self cancelling diverter to shower outlet and a plastic flow straightener. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall mounted, three-hole, metal, single outlet (fixed), combination tap assemblies (concealed brass body, various finishes - see model), incorporating quarter turn ceramic disc headwork with single lever, cross top or dome type operating members (see model). The spout outlet incorporates a plastic aerator (F7 & F9 prefix models only). Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Sensor control boxes, flow is controlled using a solenoid valve assembly. Flow is activated via infra-red sensor and product incorporates a stainless steel filter and EPDM ‘O’-rings. Maximum working pressure 7.0 bar. Maximum operating temperature 75°C.
Range of combined bath fillers and overflow waste assemblies (plated brass covers and plastic hoses) with pop-up wastes. Maximum operating temperature 65ºC. Open outlet use only.
Range of wall mounted spouts with a brass body (various finishes, see model). The outlet incorporates a plastic aerator. Maximum operating temperature - 60°C
Range of QSL stainless-steel expansion bellows with either threaded or flanged end connections. Maximum working pressure: See models. Maximum operating temperature 99°C.
Range of expansion vessels with stainless steel bodies incorporating a butyl rubber membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Models ALT-ST0019 & ALT-ST0019 are supplied with a pressure gauge. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of in-line water filters with polypropylene bodies. Maximum working pressure 8.5 bar. Cold water use only.
Non-metallic materials and components comply with BS6920 at cold water use only°C
Stainless steel press fittings for use with 316L & 304 stainless steel tube incorporating EPDM ‘O’ rings. The fittings and tube are assembled using a crimping tool. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Page 325 of 555
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.