Back To Directory SectionsRange of horizontal multistage pumps with stainless steel bodies, diffuser and impellers and EPDM ‘O’-rings. The products incorporate a graphite-SiC-EPDM shaft seal. The products incorporate a drain plug. Maximum working pressure 8.5 bar. 9Maximum operating temperature 80°C.
Range of vertical (CVM) or horizontal (CHM) multistage pumps with stainless-steel bodies and stainless-steel impellers, intermediate chambers, shaft and outer sleeve and EPDM seals. Maximum working pressure: 25 Bar. Maximum working temperature: 23°C.
Range of multistage and single stage water pumps with stainless steel bodies and impellers. Maximum working pressure 2.0 bar (AMS models), 4.0 bar (EDH & EMH models) 8.0 bar (LVS models). Maximum operating temperature 85°C
Range of pumps with stainless steel bodies. Maximum working pressure depends on model, please refer to model. Maximum operating temperature 65°C.
Range of pumps with a plastic body. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Range of booster sets consisting of two or four electronically controlled pumps, stainless steel manifold, spherical valves, expansion vessels and pressure gauge/transducers and non-return valves. Maximum operating pressure 16 bar. Maximum operating temperature 23°C.
Circulation pump with a stainless steel body. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of booster sets, incorporating a stainless-steel manifold system and between 2 and 5 pumps depending on model. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels. Maximum working pressure 16.0 Bar. Maximum operating temperature 25.0°C.
Range of shower booster pumps with brass bodies and plastic impellers. The body incorporates a single check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure: 4.0 bar. Maximum operating temperature: 70°C.
‘UPM10’ and ‘UPM20’ range of circulator pumps with a stainless-steel body, plastic impellor and EPDM ‘O’-rings. The product is supplied with EPDM gaskets for the inlet and outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
'HYDRO MULTI-E' booster set range consisting of two to four electronically controlled pumps connected in parallel and mounted on a common base frame provided with all necessary fittings. The suction manifold incorporates an isolation valve fitted between it and the individual pumps, and a pressure switch with an isolation valve. The discharge manifold incorporates an isolation valve and a non-return valve (not suitable for backflow protection), which is fitted between it and the individual pumps, it also incorporates a combined isolation and drain valve. Maximum working pressure 16.0 bar. Cold water use only.
Self-priming single stage pump, with stainless steel body, plastic impellers, stainless steel shaft, NBR 'O'-rings and seals. Maximum working pressure 6.0 bar. Maximum operating temperature 45°C.
Dutypoint ‘VMV’ range of cold water supply booster sets, incorporating 2 to 8 pumps with a modular stainless steel manifold system. VMV2, VMV3 and VMV4 pump sets are available with DN80 to DN150 manifolds depending on application. VMV5, VMV6, VMV7 and VMV8 pump sets are available with DN150 to DN200 manifolds, depending on application. The products incorporate spherical valves on both the suction and discharge manifolds, with expansion vessels, isolation valves, pressure gauges and transducers on the discharge manifolds only. Maximum working pressure 16.0 bar. Cold water use only.
Range of pumps with plastic bodies, pistons and TPE diaphragm. For use with John Guest LLDPE pipe. The products incorporate non-return valves (not suitable for backflow protection). Maximum working pressure: 8.27 Bar. Cold water use only.
Range of horizontal multistage pumps with stainless steel bodies, diffuser and impellers and EPDM ‘O’-rings. The products incorporate a graphite-SiC-EPDM shaft seal. The products incorporate a drain plug. Maximum working pressure 8.5 bar. 9Maximum operating temperature 80°C.
Range of booster pumps with stainless steel bodies, impellers and non-return valves (not suitable for backflow protection) at the inlets. Maximum working pressure: 6.0 Bar. Cold water use only.
Range of multistage and single stage water pumps with stainless steel bodies and impellers. Maximum working pressure 4.0 bar. Maximum operating temperature 85°C
Range of multistage and single stage water pumps with stainless steel bodies and impellers. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C
Range of multistage and single stage water pumps with stainless steel bodies and impellers. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C
Range of shower booster pumps (either single or double) with acetal bodies and impellers and EPDM seals and NBR `O` rings. Supplied with stainless-steel braided EPDM lined flexible hoses incorporating isolation valves Please refer to model for maximum operating pressure. Maximum operating temperature 65°C.
Range of combined storage and booster sets, incorporating a cold-water storage cistern, submersible pump, solenoid valve or alternative actuated ball valve, non-return valve (not suitable for backflow protection), isolation valves and expansion vessel. Maximum working pressure 10.0 bar. Cold water use only.
“TP/TPE series 100” single stage centrifugal pumps, incorporating cast iron (with black coloured electrocoating) or stainless-steel bodies and plastic impellers. Maximum working pressure: Cast iron models: 16.0 bar, Stainless steel models: 10.0 bar. Maximum operating temperature: Cast iron models: 60°C, Stainless steel models: 85°C.
“TPE 2 & TPE3 series” single stage centrifugal pumps, incorporating cast iron (with black coloured electrocoating) or stainless-steel bodies and plastic impellers. Maximum working pressure 10.0 bar. Maximum operating temperature: Cast iron models: 60°C, Stainless steel models: 85°C.
Range of pumps with plastic bodies. Maximum working pressures: 41.007.400 model: 0.28 bar, 41.008.400 model: 0.38 bar. Maximum operating temperature 96°C
Range of single, twin & triple cold water booster sets. The products incorporate one or more pumps, expansion vessels, isolation valves and non-return valves (not suitable for backflow protection). The twin and triple models include a suction and discharge manifold. Maximum working pressures - see model. Cold water use only.
Range of cold water booster sets comprising of multistage stainless steel pumps and manifolds with a common control panel and motor mounted inverters. The products incorporate spherical valves between the inlet and outlet manifolds and the pumps. The outlet manifold incorporates an anti-head loss valve and a flow through valve with an expansion vessel factory pre-set at 10.0 bar. Maximum working pressure 10.0 bar. Cold water use only.
Range of multistage centrifugal pumps with stainless steel impellers, intermediate chambers, shaft and outer sleeve. The Movitec VME models can also incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressures: Comeo C models 10.0 bar, Movitec VM models with an oval flange or VME models with integral check valve 16.0 bar, All other Movitec VM models 25.0 bar Maximum operating temperatures: Comeo C and Movitec VME models with integral check valve 60°C, all other model variants 100°C.
Page 4 of 4
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.