Exa Pumps SrL Approvals


#250702730

Range of horizontal multistage pumps with stainless steel bodies, diffuser and impellers and EPDM ‘O’-rings. The products incorporate a graphite-SiC-EPDM shaft seal. The products incorporate a drain plug. Maximum working pressure 8.5 bar. Maximum operating temperature 35°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
250702730
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
U3 & U5 : 1” BSP (F) inlet x 1” BSP (F) outlet. U7 : 1¼” BSP (F) inlet x 1” BSP (F) outlet. U9 : 1½” BSP (F) inlet x 1¼” BSP (F) outlet. U18 : 2” BSP (F) inlet x 1½” BSP (F) outlet.
Marking:
Felsom, Exa Pumps Srl, model and other technical info on data plate on body.
Installation Requirements:
R001 R415
Expiry date:
31/07/2030
Proviso:
The discharge from the drain plug must be via a type `AA`, `AB` or `AD` airgap, or in accordance with EN1717.
Model:
ULTRA range: U 3 – XX/Y, U 5 – XX/Y, U 7 – XX/Y, U 9 – XX/Y, U 3 – XX/Y T, U 5 – XX/Y T, U 7 – XX/Y T, U 9 – XX/Y T, U 18 – XX/Y T. (U) 3/5/7/9/18 = nominal flow rate in m³/h. XX = nominal power HPx100. U3/T (single or three phase): 50-150. U5/T (single or three phase): 70-200. U7 (single phase): 100-300. U7T (three phase): 100-350. U9/T (single or three phase): 100-250. U18 (three phase only): 180-400. Y = Number of impellers. U3, U5 (single or three phase): 2-7 stages. U7 (single phase): 2-6 stages. U7 (three phase): 2-7 stages. U9 (single or three phase): 2-5 stages. U18 (three phase only): 2-4 stages. Suffix T = 3 phase.
Product Images

Approval Holder:
Exa Pumps SrL
Company Name
Exa Pumps SrL
Address
Via Tre Confini, 23 22010 Gera Lario CO
Phone
0039 0344 910054
General Email
infor@exapumps.com

View All Listings by this Company

Print This Approval


#241002725

Range of horizontal multistage pumps with stainless steel bodies, diffuser and impellers and EPDM ‘O’-rings. The products incorporate a graphite-SiC-EPDM shaft seal. The products incorporate a drain plug. Maximum working pressure 8.5 bar. 9Maximum operating temperature 80°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241002725
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
The discharge from the drain plug must be via a type `AA`, `AB` or `AD` airgap, or in accordance with EN1717.
Size:
U 3S & U 5S models: 1” BSP (F) inlet x 1” BSP (F) outlet. U 7S models: 1¼” BSP (F) inlet x 1” BSP (F) outlet. U 9S models: 1½” BSP (F) inlet x 1¼” BSP (F) outlet. U 18S models: 2” BSP (F) inlet x 1½” BSP (F) outlet.
Marking:
Felsom, Exa Pumps Srl, model and other technical information on data plate on body.
Installation Requirements:
R001 R415
Expiry date:
31/10/2029
Model:
ULTRA S range: U X(S) - XX/Y (T) Where: U = pump type (ULTRA), X = Nominal flow-rate m³/h (3, 5, 7, 9, 18 see model list), S = ULTRA S range - stainless steel hydraulic part, XX = nominal power HPx100 (50 - 400 see model list), Y = Number of impellers (2 - 7 see model list), T = 3 phase, [blank] = single phase. U 3S models: U 3S-50/2; U 3S-70/3; U 3S-90/4; U 3S-100/5; U 3S-120/6; U 3S-150/7. U 5S models: U 5S-70/2; U 5S-80/3; U 5S-120/4; U 5S-150/5; U 5S-180/6; U 5S-200/7. U 7S models: U 7S-100/2; U 7S-120/3; U 7S-180/4; U 7S-250/5; U 7S-300/6. U 9S models: U 9S-100/2; U 9S-150/3; U 9S-200/4; U 9S-250/5. U 3S models: U 3S-50/2 T; U 3S-70/3 T; U 3S-90/4 T; U 3S-100/5 T; U 3S-120/6 T; U 3S-150/7 T. U 5S models: U 5S-70/2 T; U 5S-80/3 T; U 5S-120/4 T; U 5S-150/5 T; U 5S-180/6 T; U 5S-200/7 T. U 7S models: U 7S-100/2 T; U 7S-120/3 T; U 7S-180/4 T; U 7S-250/5 T; U 7S-300/6 T; U 7S-350/7 T. U 9S models: U 9S-100/2 T; U 9S-150/3 T; U 9S-200/4 T; U 9S-250/5 T. U 18S models: U 18S-180/2 T; U 18S-250/3 T; U 18S-400/4 T.
Product Images

Approval Holder:
Exa Pumps SrL
Company Name
Exa Pumps SrL
Address
Via Tre Confini, 23 22010 Gera Lario CO
Phone
0039 0344 910054
General Email
infor@exapumps.com

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.