Range of stainless steel indirect (single or twin coil), direct and heat pump unvented hot water storage cylinders. The heat pump models also incorporate a plate heat exchanger and a circulation pump. The secondary circuit is supplied with a temperature and pressure relief valve set at 7.0 bar@90.0˚C. The products are supplied with an inlet control group consisting of an adjustable pressure reducing valve, adjustable in the range of 0.8 bar - 6.0 bar, but factory pre-set at 3.0 bar, a strainer, am expansion relief valve set at 6.0 bar and an approved single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The products are also supplied with an immersion heater, an expansion vessel (12, 19 or 24 litres depending on model) and a tundish. Maximum supply pressure to the inlet control group: 16.0 bar. Maximum working pressure: Secondary circuit: 5.5 Bar. Primary Circuit: 6.0 Bar (All models except for the Direct - DI prefix models). Maximum operating temperature 75°C.
Range of automatic air venting valves incorporating epoxy coated, ductile iron bodies and plastic float. Maximum operating pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of wall mounted, thermostatic blending valves incorporating ceramic disc diverter cartridges. Inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to verify backflow protection. Product also had manual override button. Model VM207X and variants are supplied with variations of dome and single lever operating members. Model VM208X and variants are supplied with varaitions of cube type operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Concealed electronic thermostatic shower valve with a plastic body, the flow is controlled via two motorised valves for hot and cold supply. Both inlets incorporate a plastic strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The valve can be supplied with a variation of shower kits that can consist of the following components: handsets, overhead showers, shower hoses, wall outlets, fixed arms, and isolation valves. Maximum working pressure 7 bar. Maximum working temperature 65°C.
Wall mounted, bar type thermostatic blending valves (chromium plated brass) incorporating a ceramic cartridge headwork controlling the flow and temperature with single lever type operating member. Both inlets are supplied with a stainless-steel strainer. The inlets also incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 4.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, bar type thermostatic blending valves incorporating a quarter turn ceramic disc headwork or half turn ceramic diverter controlling the flow between outlets. The temperature is controlled by a thermostatic cartridge with various type of operating members incorporating a manual override button. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of wall mounted, thermostatic shower valves with brass bodies (chrome plated finish), incorporating a ceramic disc headwork controlling the flow to an overhead or hand shower. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member incorporating a manual override button. The product also incorporates stainless steel strainers and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with a shower handset and hose. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of exposed thermostatic shower valves with brass bodies (various finishes) incorporating a half turn ceramic disc headwork controlling the flow between 2 outlets, with the temperature being controlled independently via a thermostatic cartridge both with a single lever operating member. The inlets incorporate stainless steel strainers and approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
A range either concealed or exposed wall mounted thermostatic mixing valves with brass bodies (exposed models are chromium plated). Models CONCEALED007 & CONCEALED008 incorporate ¼ turn ceramic disc headworks and a manual diverter with a shut off. All models incorporate a thermostatic cartridge that controls the temperature. The inlets of all models incorporate stainless steel filters and approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10 bar. Maximum working temperature 60°C.
Range of wall mounted thermostatic blending valves (chrome plated brass), incorporating a quarter turn ceramic disc, half turn ceramic disc or ceramic cartridge headworks (see models). The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button, with a variety of operating members. The inlets incorporate approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection with stainless-steel strainers. Maximum working pressure 5.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Page 285 of 779
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.