#2212904

Range of high and low level BS EN 14055 (2018) WC cisterns incorporating a side or bottom entry float operated inlet valve discharging via a Type AG air gap and a dual flush or mono flush syphon for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres.. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2212904
Note:
R560 applies to bottom entry models only
Size:
½” BSP Male inlet connection
Marking:
Cap of Syphon marked either ‘Cascade +’ or ‘Dudley Turbo’ Part 3 Inlet valve marked T. Dudley or BETA (brand of Thomas Dudley) & BS1212 part 3 on front face of back plate
Installation Requirements:
R001 R280 R560 R556 R581
Expiry date:
31/12/2027
Model:
Trishell WC Cistern.
Product Images

Approval Holder:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Postcode
DY1 4SJ
Country
United Kingdom
Phone
0121 530 7053
General Email
jcresswell@thomasdudley.co.uk

View All Listings by this Company
Manufacturer:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Postcode
DY1 4SJ
Country
United Kingdom
Phone
0121 530 7053
General Email
jcresswell@thomasdudley.co.uk

View All Listings by this Company

Print This Approval


#2212064

Concealed WC dual flushing cistern with a bottom entry BS 1212 - 4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar, cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2212064
Size:
½” BSP (M)
Marking:
T1803 - WRAS, Model name and Bestter on bottom of cistern, 6 Litre inside of cistern. T1900 & T1901 - WRAS, Model name and Bestter on support bracket inside of cistern, 6 Litre inside of cistern Models Added December 2023: T1811: Bestter logo and WRAS approved product on bottom of cistern T1900 (600) – T19001 (600) t1900 Bestter logo and WRAS approved product on front of support bracket
Installation Requirements:
R001 R280 R556 R560 R571 R581
Expiry date:
31/12/2027
Model:
T1900 (500mm) with frame T1901 (500mm) without frame T1803 Models Added December 2023: T1811 T1900(600mm) T1901(600mm)
Product Images

Approval Holder:
Bestter(Xiamen) Technology lnc.
Company Name
Bestter(Xiamen) Technology lnc.
Address
No.601, Tonghong Road, Tong'an Park Tong'an Industrial Zone, Xiamen City , China

View All Listings by this Company
Manufacturer:
Bestter(Xiamen) Technology lnc.
Company Name
Bestter(Xiamen) Technology lnc.
Address
No.601, Tonghong Road, Tong'an Park Tong'an Industrial Zone, Xiamen City , China

View All Listings by this Company

Print This Approval


#2212343

WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2212343
Size:
½” BSP (M).
Marking:
R&T on adhesive label on body. R&T, model number moulded on fixed plate. 6L waterline printed within cistern.
Installation Requirements:
R001 R556
Expiry date:
31/12/2027
Model:
G3004, G3005, G3008.
Product Images

Approval Holder:
Xiamen R&T Plumbing Technology Co.,Ltd
Company Name
Xiamen R&T Plumbing Technology Co.,Ltd
Address
No.18, Houxiang Road Haicang District Xiamen
Postcode
361022
Country
China
Phone
86-0592-3959422
General Email
rt025@rtplumbing.com

View All Listings by this Company
Manufacturer:
Xiamen R&T Plumbing Technology Co.,Ltd
Company Name
Xiamen R&T Plumbing Technology Co.,Ltd
Address
No.18, Houxiang Road Haicang District Xiamen
Postcode
361022
Country
China
Phone
86-0592-3959422
General Email
rt025@rtplumbing.com

View All Listings by this Company

Print This Approval


#2212315

Concealed WC dual flushing cistern with a side entry BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure – 10.0 bar, cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2212315
Size:
½” BSP (M).
Marking:
R&T, model code printed on fixed plate. 6L waterline printed within cistern.
Installation Requirements:
R001 R556 R571 R581
Expiry date:
31/12/2027
Model:
G3003.

Approval Holder:
Xiamen R&T Plumbing Technology Co.,Ltd
Company Name
Xiamen R&T Plumbing Technology Co.,Ltd
Address
No.18, Houxiang Road Haicang District Xiamen
Postcode
361022
Country
China
Phone
86-0592-3959422
General Email
rt025@rtplumbing.com

View All Listings by this Company
Manufacturer:
Xiamen R&T Plumbing Technology Co.,Ltd
Company Name
Xiamen R&T Plumbing Technology Co.,Ltd
Address
No.18, Houxiang Road Haicang District Xiamen
Postcode
361022
Country
China
Phone
86-0592-3959422
General Email
rt025@rtplumbing.com

View All Listings by this Company

Print This Approval


#2301072

Concealed WC dual flushing cistern with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. Maximum working pressure - 10 Bar Maximum operating temperature – Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2301072
Size:
½” BSP (M)
Marking:
Roper Rhodes Group and model number on sticker on front of cistern. 6 Litre line inside of cistern
Installation Requirements:
R001 R280 R556 R571 R581
Expiry date:
31/01/2028
Model:
TR9001 / VOR790/ INST13001
Product Images

Approval Holder:
Roper Rhodes Ltd
Company Name
Roper Rhodes Ltd
Address
Brassmill Lane Industrial Estate Bath
Postcode
BA1 3JF
Country
United Kingdom
General Email
paulw@roperrhodes.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 29 of 45

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.