Directory Search Results

Print List

#2106027

Range of gate valves with brass bodies, brass wedges and PTFE packing glands. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.

Section:
2290 Valves
Section Subtitle:
Stop, gate, metal.
WRAS Approval Number:
2106027
Marking:
ITAP logo (‘i’ within a box), DN, PN and size on body.
Installation Requirements:
R001
Expiry date:
30/06/2026
Model:
1560012 - ½” BSP (F) (DN15), 1560034 - ¾” BSP (F) (DN20), 1560100 - 1” BSP (F) (DN25), 1560114 - 1 ¼” BSP (F) (DN32), 1560112 - 1 ½” BSP (F) (DN40), 1560200 - 2” BSP (F) (DN50), 1560212 - 2 ½” BSP (F) (DN65). Models added January 2022: 1560300 - 3” BSP (F) (DN80), 1560400 - 4” BSP (F) (DN100).
Product Images

Approval Holder:
Itap Spa
Company Name
Itap Spa
Address
Via Ruca 19. 25065 Lumezzane (BS), Italy
Postcode
25065
Phone
+39 030 89270
General Email
info@itap.it

View All Listings by this Company

Print This Approval


#2106330

Range of gate valves with blue epoxy resin coated cast iron (DN65-80) or ductile iron (DN100-200) bodies, EPDM coated ductile iron wedge and EPDM gaskets. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Cold water use only.

Section:
2290 Valves
Section Subtitle:
Stop, gate, metal.
WRAS Approval Number:
2106330
Size:
see model
Marking:
Herz logo, DN, PN and CE mark on body. Herz logo and part no. (first 5 digits) on data label on body.
Installation Requirements:
R001
Expiry date:
30/06/2026
Model:
Flanged PN16 to BS EN 1092-2: 4 4113 71: DN65. 4 4113 72: DN80. 4 4113 73: DN100. 4 4113 74: DN125. 4 4113 75: DN150. 4 4113 76: DN200.
Product Images

Approval Holder:
Herz Armaturen GmbH
Company Name
Herz Armaturen GmbH
Address
Richard - Strauss Strasse 22, A-1230, Vienna
Country
Austria

View All Listings by this Company
Manufacturer:
Herz Armaturen GmbH
Company Name
Herz Armaturen GmbH
Address
Richard - Strauss Strasse 22, A-1230, Vienna
Country
Austria

View All Listings by this Company

Print This Approval


#2106036

Range of cold-water inlet control groups with DZR brass bodies consisting of an in-line, adjustable pressure reducing valve (PRV) (adjustable in the range of 0.8 bar - 6.0 bar, but factory pre-set at 3.0 or 3.5 bar - see model), strainer and a DZR brass bodied pressure relief valve (SRV) (set at 4.75 bar or 6.0 bar - see model). Products also incorporate an approved single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum supply pressure 16.0 bar. Maximum operating temperature 80°C.

Section:
2345 Valves
Section Subtitle:
Special combination assemblies.
WRAS Approval Number:
2106036
Size:
22mm compression
Marking:
RBM on cap. CR, size and flow arrow on body.
Installation Requirements:
R001 R120
Expiry date:
30/06/2026
Model:
UVGS21822200.1 - 22mm INLET 3 BAR PRV, 4.75 BAR SRV, UNVENTED GROUP SET WITH 3/4" EXPANSION VESSEL CONNECTION. UVGS21822210.1 - 22mm INLET 3 BAR PRV, 6 BAR SRV, UNVENTED GROUP SET WITH 3/4" EXPANSION VESSEL CONNECTION. UGVS21822211 - 22mm INLET 3.5 BAR PRV, 6 BAR SRV, UNVENTED GROUP SET WITH 3/4" EXPANSION VESSEL CONNECTION. UVGS21822220.1 - 22mm INLET 3 BAR PRV, 6 BAR SRV, UNVENTED GROUP SET WITH 22mm EXPANSION VESSEL CONNECTION. UVGS21822260.1 - 22mm INLET 3 BAR PRV, 6 BAR SRV, UNVENTED GROUP SET NO VESSEL CONNECTION.

Approval Holder:
Intatec Limited
Company Name
Intatec Limited
Address
Airfield Industrial Estate Hixon Staffordshire
Postcode
ST18 0PF
Country
United Kingdom
Phone
01889272180
General Email
ryan.tilsley@intatec.co.uk

View All Listings by this Company
Manufacturer:
RBM S.p.a.
Company Name
RBM S.p.a.
Address
Componenti Per Impianti Idrotermici Via S. Giuseppe, 1 25075 Nave (Brescia)
Country
Italy
General Email

View All Listings by this Company

Print This Approval


#2103301

Range of ion generating water conditioners incorporating UPVC pipework and fittings, flow meter and stainless steel electrode pens contained within the electrode chamber. Maximum working pressure 9.0 bar. Cold water use only.

Section:
2415 Water conditioners - Disinfectant ion generators
Size:
50mm pipe connection
Marking:
ICA, Water ionisation treatment on control panel. ICA water ionisation treatment on filter. Ateca, model. KIWA and other technical information on mounting plate.
Installation Requirements:
R001 R120 R150 R170 R290
Expiry date:
31/03/2026
Model:
ICA 100, 200, 300, 400, 500, 600
Product Images

Approval Holder:
Ateca Production BV
Company Name
Ateca Production BV
Address
Ruychrocklaan 121 2597 EL Den Haag
Country
Netherlands
Phone
+31 70 3628175
General Email
info@@ateca.nl

View All Listings by this Company
Manufacturer:
Ateca Production BV
Company Name
Ateca Production BV
Address
Ruychrocklaan 121 2597 EL Den Haag
Country
Netherlands
Phone
+31 70 3628175
General Email
info@@ateca.nl

View All Listings by this Company

Print This Approval


#2104062

Range of ion exchange water softeners (salt regenerated) for domestic use. Maximum working pressure 6.0 bar. Cold water use only.

Section:
2450 Water softeners
Size:
¾” BSP (M) inlet/outlet or 1” BSP (M) inlet/outlet
Marking:
MONARCH WATER ON FRONT OF BODY MONARCH WATER COMPANY INFORMATION, MODEL & PRODUCT INFORMATION ON ADHESIVE LABEL ON REAR OF BODY
Installation Requirements:
R001 R150 R170 R290 R415
Expiry date:
30/04/2026
Proviso:
Discharge to drain must be via a type `AA`, `AB` or `AD` air gap in accordance with EN1717.
Model:
MONARCH RANGE EXCHANGE WATER SOFTENERS : Mini Aqua HE, CS100HE, PROSOFT100HE, EVER 9, Midi HE, CS150HE, PROSOFT150HE, EVER 12, Master HE, CS200HE, PROSOFT200HE, EVER 18, Matrix HE ,CS300HE, PROSOFT300HE, EVER 30, PS12 HE, PS15 HE, GS4000 HE, GS6000 HE, LPS HE, SOF3000HE & SOF6000HE
Product Images

Approval Holder:
Monarch Water Ltd
Company Name
Monarch Water Ltd
Address
Fair Green Diss Norfolk
Postcode
IP22 4DG
Country
United Kingdom
Phone
01986 784759
General Email
kdelaney@monarchwater.co.uk

View All Listings by this Company

Print This Approval


#2106529

'TEPCON® M90 NAT CF2001 & TEPCON® M270 NAT CF2001'. Natural (appears white in colour), injection moulded acetal materials. For use with hot and cold water up to 85°C.

Section:
5015 Acetal
Section Subtitle:
Material only. Components made from materials listed in this section may be required to be submitted for audit tests.
WRAS Approval Number:
2106529
Expiry date:
30/06/2026

Approval Holder:
Polyplastics Taiwan Co. Ltd.
Company Name
Polyplastics Taiwan Co. Ltd.
Address
Plant No. 13, Jianye Road, Chao Liao Village, Daliao District, Kaohsiung City, Taiwan
Country
China

View All Listings by this Company

Print This Approval


#2101521

'V-PET#1600 GRAY AG'. Factory applied, grey coloured epoxy powder paint. Apply as per manufacturer's instructions ref '20210201-1' dated 2021/2/1. Cure for 10 minutes@200°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
2101521
Expiry date:
31/01/2026

Approval Holder:
Dai Nippon Toryo Co. Ltd.
Company Name
Dai Nippon Toryo Co. Ltd.
Address
1-18-11 Minamifunaba Tyuoku Osaka-shi, Osaka 542-0081, SR building Nagahori
Country
Japan

View All Listings by this Company

Print This Approval


#2101523

'High Build Solvent Free Epoxy Coating Red'. Factory applied, red coloured epoxy coating. Apply as per manufacturer's user instructions reference 'SPL/RD/UI/202006119', issue no, '01' dated 20.08.2020. Cure for 24 hours@30°C. For use with water up to 50°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
2101523
Expiry date:
31/01/2026

Approval Holder:
Shalimar Paints Limited
Company Name
Shalimar Paints Limited
Address
Nashik Mumbai NH Road, Gonde, Nashik, Maharashtra 422403
Country
India

View All Listings by this Company

Print This Approval


#2101530

'Jotaguard VA 5001. Factory applied, blue coloured epoxy coating. Apply as per manufacturer's TDS dated '9 November 2015'. Cure for 210 seconds@200°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
2101530
Expiry date:
31/01/2026

Approval Holder:
Jotun Coatings (Zhangjiagang) Co. Ltd.
Company Name
Jotun Coatings (Zhangjiagang) Co. Ltd.
Address
Floor 20, Jiu Shi Mansions, No. 28 Zhongshan Road (South), Shanghaim 200010
Country
China

View All Listings by this Company

Print This Approval


#2102509

'V-PET #1600 Gray F'. Factory applied, grey coloured epoxy resin powder coating. Apply as per manufacturer`s instructions ref. no. '20210216-1' dated 2021/2/16. Cure for 10 minutes@200°C. For use with water up to 60°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5030 Coatings, Paints & Linings
Section Subtitle:
Factory applied pipe & fittings coatings.
WRAS Approval Number:
2102509
Expiry date:
28/02/2026

Approval Holder:
Dai Nippon Toryo Co. Ltd.
Company Name
Dai Nippon Toryo Co. Ltd.
Address
1-18-11 Minamifunaba Tyuoku Osaka-shi, Osaka 542-0081, SR building Nagahori
Country
Japan

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 28 of 112

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.