Directory Search Results

Print List

#2112033

Range of WC pressure flushing valves with a solenoid valve controlling the flow. The valves are operated via an infra-red sensor or push-button assembly. The solenoid valve also incorporates a lever operated isolation valve. Maximum working pressure – 5.0 Bar. Cold water use only

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not been verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2112033
Size:
¾” BSP (M)
Marking:
Delable on Faceplate
Installation Requirements:
R001 R120 R090 R410 R570
Expiry date:
31/12/2026
Model:
464000, Tempomatic WC recessed bicontrol plate 464006, Tempomatic WC recessed bicontrol plate 464PBOX, Tempomatic WC recessed 464SBOX, Tempomatic WC recessed
Product Images

Approval Holder:
Delabie UK Ltd.
Company Name
Delabie UK Ltd.
Address
18,rue du Maréchal Foch Friville Escarbotin
Postcode
80210
Country
France
General Email
sebastien.spriet@delabie.fr

View All Listings by this Company
Manufacturer:
Delabie UK Ltd.
Company Name
Delabie UK Ltd.
Address
18,rue du Maréchal Foch Friville Escarbotin
Postcode
80210
Country
France
General Email
sebastien.spriet@delabie.fr

View All Listings by this Company

Print This Approval


#2201339

Range of stainless-steel plate heat exchangers with EPDM gaskets. The primary circuit, (excluding the E2 prefix models), incorporates a drain valve and a pump (excluding STP prefix models including an ‘N’ as the 14th figure). Operating parameters: Maximum working pressure of the secondary circuit: 6.0 bar or 10.0 bar (see model). Maximum working pressure of the primary circuit: E4 models: 6.0 bar. C3, E3, E2, i2: 10.0 bar. Models added February 2023 – Econoplate STP3, STC3, STP2, STC2 & STP4: 10.0 bar. Maximum operating temperature: Primary 140°C & Secondary 85°C.

Section:
1350 Heat Exchangers
Size:
Secondary: 1½” BSP (F) or 2” BSP (F), as well as 1” BSP (F) recirculation connection where fitted. Primary: DN40 or DN50 flanged inlet, 1½” BSP (M) or 2” BSP (M) outlet.
Marking:
Stokvis logo, Stokvis, Econoplate & model, pressure, flow rate, WRAS and other technical information on data plate on body.
Installation Requirements:
R001 R511
Expiry date:
31/01/2027
Model:
Econoplate models: Following models xx goes from 5-59 to denote number of plates. E4Axx, E4Aixx, E4Bxx, E4Bixx, E3A1xx, E3Ai1xx, C3Ai1xx, E3A3xx, E3Ai3xx, C3Ai3xx, i2Axx, i2Bxx, E2A(##)xx, E2B(##)xx, E4AxxD, E4AixxD, E4BxxD, E4BixxD, E3A1xxD, E3Ai1xxD, C3Ai1xxD, E3A3xxD, E3Ai3xxD, C3Ai3xxD, i2AxxD, i2BxxD. Following models xx goes from 11-74 to denote number of plates: E3Cxx, E3Cixx, C3Cixx, i2Cxx, E2C(##)xx, E3CxxD, E3CixxD, C3CixxD, i2CxxD. FIRST LETTER: E = MODELS PAINTED YELLOW. C = MODELS ARE IDENTICAL TO E MODELS BUT PAINTED WHITE. i = Fitted with a speed controlled primary pump (2 port models only). FIRST NUMBER: PRIMARY CONTROL VALVE TYPE/NO. OF PORTS - 2, 3 or 4. NEXT LETTER RELATES TO FRAME SIZE OR PRIMARY CONTROL SET (PUMP & OR CONTROL VALVE) SIZE: Frame size - A, B or C. When fitted with a speed controlled primary pump add an i (3 and 4 port models only). When fitted with twin head primary pump add a D to model designation after the number xx. xx = number of (heat exchanger) plates All model names are followed by +0R where: +0R = no secondary pump. ## added to differentiate primary fluids and can be replaced with the following: SW = steam to water. LTHWS = low temperature heating to domestic hot water. MTHWS = medium temperature heating to domestic hot water. Units with a secondary pressure of 10.0 bar use stainless connections and are denoted by ’10 bar’ at end of model number. Units with a secondary pressure of 6.0 bar use bronze connections which are standard fitment so no addition or alteration to model number. All models can be fitted with either 1.5” or 2” secondary circuit connections, this does not affect the product model number. Models added February 2023 - Econoplate STP3, STC3, STP2, STC2 & STP4: ST (first 2 figures) – Signifies a Stokvis product on all models. All Econoplate models are orange in colour. P or C (3rd figure) – Signifies small or large chassis (P = 1.5” primary connections, C = 2” primary connections). 2, 3, or 4 (4th figure) – Signifies configuration of chassis to suit control valve, 2, 3 or 4 port. A, B, or C (5th figure) – Signifies secondary connection sizes (A = 1.5”, B = 2.0”, C = 2.0” stainless). 5 – 59 (P chassis), 11 – 74 (C chassis) (6th & 7th figure) – Signifies number of identical plates on unit. H, L, or M (8th Figure) – Signifies heat exchanger plate design (H = High theta, L = Low theta, M (mixed) = Combination of H & L). T1 or T2 (9th & 10th figure) – Signifies type of control panel (T1 = Standard control panel, T2 = Touchscreen premium panel). 2, 3, or 4 (11th figure) – Signifies primary control valve/s configuration (2 = 2 port, 3 = 3 port, 4 = 4 port). S, D, or N (12th figure) – Signifies primary pump configuration (S = Single head, D = Dual head, N = No primary pump fitted). 1 or 4 (13th figure) – Signifies number of temp sensors fitted to unit (1 = 1, 4 = 4). N (14th Figure) – Signifies no secondary pump fitted. Example: STP3A17HT13S4N
Product Images

Approval Holder:
Stokvis Energy Systems
Company Name
Stokvis Energy Systems
Address
96R Walton Road East Molesey Surrey
Country
KT8 0DL

View All Listings by this Company
Manufacturer:
Stokvis Energy Systems
Company Name
Stokvis Energy Systems
Address
96R Walton Road East Molesey Surrey
Country
KT8 0DL

View All Listings by this Company

Print This Approval


#2111377

Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C

Section:
1390 Heaters
Section Subtitle:
Electric, thermal storage, mains fed, open outlet.
WRAS Approval Number:
2111377
Size:
3/8” BSP
Marking:
CLEARWATER on front of heater Model and other tech info on adhesive label on body
Installation Requirements:
R001
Expiry date:
30/11/2026
Model:
2.4L,1500KW: CWT124T CWT024T CWT023T 4L,2300KW: CWT140T
Product Images

Approval Holder:
Clearwater Products Ltd
Company Name
Clearwater Products Ltd
Address
Unit 5603 Shannon Place Tewkesbury Place
Postcode
GL20 8SL

View All Listings by this Company

Print This Approval


#2111379

Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C

Section:
1390 Heaters
Section Subtitle:
Electric, thermal storage, mains fed, open outlet.
WRAS Approval Number:
2111379
Size:
3/8” BSP
Marking:
HC DRINK (COMPANY BRAND) ON FRONT OF BODY model and other tech info on adhesive label on body
Installation Requirements:
R001
Expiry date:
30/11/2026
Model:
2.4L,1500KW: LS5001351-11, LS5001351-12, LS5001351-21, LS5001351-22, LS5001352-11, LS5001352-12, LS5001352-21, LS5001352-22, LS5001353-11, LS5001353-12, LS5001353-21, LS5001353-22, LS5001354-12, LS5001354-32, LS5001354-22, LS5001354-42, LS5001355-11, LS5001355-12, LS5001355-21, LS5001355-22, LS5001357-11, LS5001357-12, LS5001357-21, LS5001357-22, LS5001358, LS5001361, LS5001362, LS5001363, LS5001364, LS5001365, LS5001366, LS5001367, LS5001368. 4L,2300KW: LS5001371, LS5001374, LS5001372-01, LS5001372-02, LS5001372-03, LS5001372-04, LS5001376-01, LS5001376-02, LS5001376-03, LS5001377-01, LS5001377-02, LS5001377-03, LS5001377-04, LS5001373, LS5001375.

Approval Holder:
XIAMEN IWATER TECHNOLOGY CO.,LTD.
Company Name
XIAMEN IWATER TECHNOLOGY CO.,LTD.
Address
Unit 201,Building #5 Haiyi Industrial Park,No.7,Kengping Road,Jimei District ,Xiamen
Country
China

View All Listings by this Company

Print This Approval


#2112354

Range of gas fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The cold inlet incorporates an angled spherical valve with a brass body, chromium plated brass ball and a lever operating member. The primary circuit incorporates an expansion vessel, isolation valves on flow and return, drain valve and a pressure relief valve set at 3.0 bar. Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature for the secondary circuit is 55˚C. Cold supply only.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2112354
Size:
Secondary: 15mm copper tail. Primary: 22mm copper tail.
Marking:
Biasi and Biasi logo on front panel. Biasi, Biasi logo, pressure, model and other technical information on label on inside cover.
Installation Requirements:
R001 R140 R360
Expiry date:
31/12/2026
Model:
Advance Plus 25C ERP, Advance Plus 30C ERP, Advance Plus 35C ERP, M300V.2025 SM, M300V.2530 SM, M300V.3035 SM, M275V.2024 SM, M275V.2428 SM, M275V.2832 SM.
Product Images

Approval Holder:
BSG Caldaie a gas S.p.A.
Company Name
BSG Caldaie a gas S.p.A.
Address
Via Pravolton 1/b Pordenone
Postcode
33170
Country
Italy
Phone
+39 0434 238311
General Email
luca_norio@bsgspa.it

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 233 of 1240

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.