'Hurricane' range of Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 3.0 bar & Solar circuit 5.5 bar. Maximum operating temperature 65°C.
Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. Fitted with a Caleffi 309463 GLD temperature and pressure relief valve sat at 6 bar & 90°C, and supplied with an inlet control group consisting of in-line pressure reducing valve (Caleffi set at 3 bar) and pressure relief valve (Caleffi CWIC200055) set at 4.5 bar, and incorporates a stainless-steel mesh and an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2), expansion vessel and filling loop. Maximum working pressure 4.4 bar. Maximum operating temperature 99°C.
Range of 2 and 3 port manifold assemblies with brass bodies incorporating ‘Tectite Classic’ push-fit fittings for use with either copper pipe (manufactured to EN1057), PEX pipe (manufactured to BS7291-3:2010) or PB pipe (manufactured to BS7291-2). Maximum working temperature and pressure: Use with copper pipe: 16.0 bar @ 30°C, 10.0 bar @ 65°C & 6.0 bar @ 95°C. Use with PEX & Polybutylene: 12.0 bar @ 20°C, 6.0 bar @ 65°C & 3.0 bar @ 92°C.
Non-metallic materials and components comply with BS6920 at See description °C
6300E7 series of nickel plated brass manifolds and 6300R8 series of chromium plated brass manifolds with two, three or four outlets, for use with copper pipe (manufactured to EN1057). The products incorporate a screw down isolation valve at each port. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Range of T-type thermostatic mixing valves (chrome plated DZR brass). The 521928 model incorporates stainless steel strainers in the inlets and approved check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure: 10.0 Bar. Temperature: 90°C
Range of wall mounted, exposed, thermostatic shower mixing valves (chromium plated brass). The products incorporate a ¼ turn ceramic disc or a 2-way ceramic disc diverter headwork (see model). Temperature is controlled independently via a thermostatic cartridge with a manual override button. The products have dome type operating members. Each inlet incorporates a combined EPDM washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, concealed thermostatic blending valves with (brass bodies – various chrome plated trim sets). The flow is controlled by either a quarter turn ceramic disc headwork, a ceramic disc diverter valve or both using single lever or cubed type operating members. The temperature is controlled via a thermostatic cartridge using a cross-top, cubed or single lever operating members. The products incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate the is provides backflow protection. Maximum working pressure 8.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall mounted, bar type thermostatic shower mixer (chromium plated brass) Incorporating a quarter turn headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets and shower outlet incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets also incorporate stainless steel strainers. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Wall mounted thermostatic shower valve (chrome plated brass body), incorporating a non-rising spindle headwork controlling the flow. The temperature is controlled independently with a thermostatic cartridge, both using single lever operating members. The inlets incorporate flow regulators, plastic strainers and approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower kit that consists of a shower handset, shower hose and riser rail assembly. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of thermal circulation valves with gunmetal bodies and EPDM ‘O’-rings. Models incorporate drain valves. Maximum operating pressure 16.0 bar. Maximum operating temperature 90°C.
Page 227 of 408
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.