Directory Search Results

Print List

#2012511

'E7008W'. Black coloured, compression moulded EPDM material. Shore hardness 70. Tested in-radius size 1.05mm. For use with water up to 85°C.

Section:
5365 Rubbers
Section Subtitle:
Ethylene Propylene Diene Monomer (EPDM) - material only. Components made from materials listed in this section may be required to be submitted for audit tests.
WRAS Approval Number:
2012511
Expiry date:
31/12/2025

Approval Holder:
Best Ring Technology Co. Ltd.
Company Name
Best Ring Technology Co. Ltd.

View All Listings by this Company

Print This Approval


#2011533

'kSil GP40 - GP-70'. Extruded, silicone rubber material available in translucent (which appears off-white), black, white, red and blue colours. Shore hardness between 40 & 70. Tested in-radii sizes between 0.15mm & 6.0mm. For use with water up to 85°C.

Section:
5415 Rubbers
Section Subtitle:
Silicone - material only. Components made from materials listed in this section may be required to be submitted for audit tests.
WRAS Approval Number:
2011533
Expiry date:
30/11/2025

Approval Holder:
Silicone Engineering Ltd.
Company Name
Silicone Engineering Ltd.
Address
Greenbank Business Park, Blakewater Road, Blackburn
Postcode
BB1 3HU
Country
Lancashire
Phone
+44 (0) 1254 261321
General Email
sales@silicone.co.uk

View All Listings by this Company

Print This Approval


#2011069

Range of wall mounted, two hole, single outlet (fixed) mains electric or battery controlled tap assemblies (chromium plated brass) incorporating approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection . The flow is controlled via a solenoid valve activated via an infra-red sensor. The inlet to the solenoid incorporates a stainless-steel strainer. The tap is supplied with spherical valves for both hot and cold inlets. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
2011069
Size:
½” Male BSP.
Marking:
Model number and date (WW/YY) on underside of tap. INTA on operating member.
Installation Requirements:
R001 R010 R040
Expiry date:
30/11/2025
Model:
Mains Operated: HTMWMMCP HTMWMMRS - Removable Spout Battery Operated: HTMWMBRS – Removable Spout HTMWMBCP
Product Images

Approval Holder:
Intatec Limited
Company Name
Intatec Limited
Address
Airfield Industrial Estate Hixon Staffordshire
Postcode
ST18 0PF
Country
United Kingdom
Phone
01889272180
General Email
ryan.tilsley@intatec.co.uk

View All Listings by this Company
Manufacturer:
Intatec Limited
Company Name
Intatec Limited
Address
Airfield Industrial Estate Hixon Staffordshire
Postcode
ST18 0PF
Country
United Kingdom
Phone
01889272180
General Email
ryan.tilsley@intatec.co.uk

View All Listings by this Company

Print This Approval


#2012008

Single hole, single outlet, fixed electronically controlled tap assemblies with brass bodies (chrome plated), incorporating a solenoid valve controlling the flow which is activated via an infrared sensor. The spout outlet incorporates a plastic aerator, and the product is supplied with a metal backnut. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
2012008
Size:
½” BSP (M)
Marking:
MCM and product code on rear of tap body
Installation Requirements:
R001 R006 R008
Expiry date:
31/12/2025
Model:
Code 7035B – Electronic basin tap powered by battery Code 7035C – Electronic basin tap powered by electricity Models added June 2023 703500 CR - Electronic basin tap powered by electricity 703500 BM - Electronic basin tap powered by electricity 703500 NM - Electronic basin tap powered by electricity 703500 PG - Electronic basin tap powered by electricity 703500 PC - Electronic basin tap powered by electricity 703500 PM - Electronic basin tap powered by electricity 703501 CR - Electronic basin tap powered by battery 703501 BM - Electronic basin tap powered by battery 703501 NM - Electronic basin tap powered by battery 703501 PG - Electronic basin tap powered by battery 703501 PC - Electronic basin tap powered by battery 703501 PM - Electronic basin tap powered by battery
Product Images

Approval Holder:
Rubinetterie MCM Intl. Srl.
Company Name
Rubinetterie MCM Intl. Srl.
Address
Via Dell'Acacia 54 I-28021 Borgomanero Italy

View All Listings by this Company
Manufacturer:
Rubinetterie MCM Intl. Srl.
Company Name
Rubinetterie MCM Intl. Srl.
Address
Via Dell'Acacia 54 I-28021 Borgomanero Italy

View All Listings by this Company

Print This Approval


#2011343

Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a plastic filter. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2075 Float Operated Inlet Valve
Section Subtitle:
Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
WRAS Approval Number:
2011343
Size:
3/8” BSP (M) brass Models added January 2021 ½” BSP (M) brass or plastic
Marking:
Siamp, BS1212-4, WRAS logo and EN14124-11 on float
Installation Requirements:
R001 R550 R573
Expiry date:
30/11/2025
Model:
Compact 95L Air Gap
Product Images

Approval Holder:
Siamp Vietnam
Company Name
Siamp Vietnam
Postcode
MONACO

View All Listings by this Company
Manufacturer:
Siamp Vietnam
Company Name
Siamp Vietnam
Postcode
MONACO

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 222 of 2215

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.