#2103036

Centerstore ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103036
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
Centerstore (Trademark of Wolseley) on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/03/2026
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
174767 CENTERSTORE 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174768 CENTERSTORE 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. 174769 CENTERSTORE 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER 174770 CENTERSTORE 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. 174771 CENTERSTORE 170 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER 174772 CENTERSTORE 200 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDE 174773 CENTERSTORE 250 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER 174774 CENTERSTORE 300 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER 174787 CENTERSTORE SLIM 120 INDIRECT HOT WATER STORAGE CYLINDER 174788 CENTERSTORE SLIM 150 INDIRECT HOT WATER STORAGE CYLINDER 174789 CENTERSTORE SLIM 170 INDIRECT HOT WATER STORAGE CYLINDER 174790 CENTERSTORE SLIM 200 INDIRECT HOT WATER STORAGE CYLINDER 174791 CENTERSTORE SLIM 120 DIRECT HOT WATER STORAGE CYLINDER 174792 CENTERSTORE SLIM 150 DIRECT HOT WATER STORAGE CYLINDER 174793 CENTERSTORE SLIM 170 DIRECT HOT WATER STORAGE CYLINDER 174794 CENTERSTORE SLIM 200 DIRECT HOT WATER STORAGE CYLINDER
Product Images

Approval Holder:
Wolseley UK Ltd.
Company Name
Wolseley UK Ltd.
Address
2 Kingmaker Court, Warwick Technology Park, Warwick
Postcode
CV34 6DY
Country
United Kingdom
Phone
01926705792
General Email
martin.lister@wolseley.co.uk

View All Listings by this Company

Print This Approval


#2210052

Range of indirect unvented indoor heat pump storage cylinders which consist of a heat pump which sits on top of the tank and heats the hot water via refrigeration pipes which then heats the cylinder by being externally mounted around the cylinder. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressure 6.0 Bar (Secondary) Maximum operating temperature 55.0°C

Section:
1890 Unvented Heating Apparatus
Size:
¾” BSP (F)
Marking:
KERS logo, model name, capacity, max pressure, max temp and other technical information on label on body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/10/2027
Model:
KERS OA - W230 KERS MVHR - W230 KERS MVHR - W200 SL KERS OA -W200 SL KERS MVHR - W160 KERS OA - W160
Product Images

Approval Holder:
KERS INNOVATION UK LTD
Company Name
KERS INNOVATION UK LTD
Address
Unit 3 ALBERT STREET, HOLLINWOOD, OLDHAM, OL8 3QPCompany

View All Listings by this Company

Print This Approval


#2211041

Range of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The secondary circuit consists of a temperature and pressure relief valve set at 10.0 bar and 90°C and an alternative temperature and pressure relief valve also set at 10.0 bar and 90°C , an inlet control group consisting of a pressure reducing valve pre-set at 3.0 bar, an expansion relief valve set at 8.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum working pressure - Primary circuit: 6.0 bar & Secondary circuit: 7.5 bar Maximum operating temperature 85.0°C

Section:
1890 Unvented Heating Apparatus
Size:
22mm Compression on all circuits
Marking:
EVOCyle logo, max pressure, max temp, capacity and other technical information on label on body.
Installation Requirements:
R001 R140 R360
Expiry date:
30/11/2027
Model:
TTAMVD-0150LFB ThermaQ Evocyl Air 150 Direct TTAMVD-0180LFC ThermaQ Evocyl Air 180 Direct TTAMVD-0210LFC ThermaQ Evocyl Air 210 Direct TTAMVD-0250LFC ThermaQ Evocyl Air 250 Direct TTAMVD-0300LFC ThermaQ Evocyl Air 300 Direct TTAMVI-0150LFB ThermaQ Evocyl Air 150 Indirect TTAMVI-0180LFC ThermaQ Evocyl Air 180 Indirect TTAMVI-0210LFC ThermaQ Evocyl Air 210 Indirect TTAMVI-0250LFC ThermaQ Evocyl Air 250 Indirect TTAMVI-0300LFC ThermaQ Evocyl Air 300 Indirect
Product Images

Approval Holder:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company
Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval


#2209312

Wall mounted, exposed, manual blending valve (brass body, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
2000 Shower Valves
Section Subtitle:
Shower valve(s) with manual temperature control.
WRAS Approval Number:
2209312
Note:
This approval does not include a shower hose and handset.
Size:
¾” x ½” offset union
Marking:
Hansgrohe on operating member.
Installation Requirements:
R001 R010 R040
Expiry date:
30/09/2027
Model:
72 640 xxx Hansgrohe Rebris S, 72 650 xxx Hansgrohe Rebris E. Where xxx denotes the surface finish (which is a non-water contact part). It will always be 3 digits, which can be any combination of numbers and/or letters. As examples: 000 = chrome optic finish, 800 = PVD stainless steel optic finish.
Product Images

Approval Holder:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company
Manufacturer:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company

Print This Approval


#2211044

Range of wall mounted thermostatic blending valves (brass bodies), with ceramic cartridge headworks controlling the temperature and the flow and a manual diverter that diverts the flow to two outlets. Both have single lever operating members. Maximum working pressure 5.0 Bar Maximum operating temperature 65°C.

Section:
2000 Shower Valves
Section Subtitle:
Shower valve(s) with manual temperature control.
WRAS Approval Number:
2211044
Size:
½” BSP (F)
Marking:
VOLA on operating member and valve body
Installation Requirements:
R001 R010 R040
Expiry date:
30/11/2027
Model:
VOLA 400V, VOLA 400FV, VOLA 400NV, VOLA 400RV, VOLA 400TV
Product Images

Approval Holder:
Vola A/S
Company Name
Vola A/S
Address
Lunavej 2 Horsens
Postcode
8700
Country
Denmark
Phone
+4576284846
General Email
mk@vola.dk

View All Listings by this Company
Manufacturer:
Vola A/S
Company Name
Vola A/S
Address
Lunavej 2 Horsens
Postcode
8700
Country
Denmark
Phone
+4576284846
General Email
mk@vola.dk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 216 of 558

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.