#251102026

Range of overhead shower outlets with (stainless steel bodies - various finishes). The inlet incorporates a combined EPDM washer and an approved check valve cartridge: however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure: Open outlet use only. Maximum operating temperature 65.0°C

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
251102026
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (F)
Marking:
81xx8053 model: ABOUTWATER (brand of Fratelli Fantini S.p.A.) on body. 86xx8083 model: FANTINI on body.
Installation Requirements:
R001 R040
Expiry date:
30/11/2030
Model:
81xx8053 86xx8083 Where xx denotes finish and can be replaced by: 01 = Gold plus, 02 = Chrome, 13 = Matt Black, 29 = Matt White, 38 = 93 = Brushed Stainless steel, 95 = Nickel PVD, P5 = Matt Gun Metal PVD, P6 = Matt British Gold PVD, P9 = Matt Copper PVD, S1 = Deep Black PVD, Q7 = Pure Brass PVD, Q8 = Raw Metal PVD.

Approval Holder:
Fratelli Fantini Spa
Company Name
Fratelli Fantini Spa
Address
Via Buonarroti 4 28010 Pella Italy

View All Listings by this Company

Print This Approval


#251102031

Range of shower handsets with (plastic bodies - various finishes), incorporating an approved single check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure: Open outlet use only Maximum operating temperature: 60°C.

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
251102031
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1/2" BSP (M)
Marking:
Villeroy & Boch on body
Installation Requirements:
R001 R040
Expiry date:
30/11/2030
Model:
TVS11000100061 TVS110001000K5

Approval Holder:
Villeroy & Boch AG
Company Name
Villeroy & Boch AG
Address
Saaruferstraße 1-3 Mettlach
Postcode
66693
Country
Germany
Phone
+49 151 16775778
General Email
Finkler.Marc@villeroy-boch.com

View All Listings by this Company

Print This Approval


#251102039

Range of shower handsets with chromium plated plastic bodies. Maximum operating temperature 65.0°C Open outlet use only

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
251102039
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M)
Marking:
Grohe on handset
Installation Requirements:
R001 R040
Expiry date:
30/11/2030
Model:
27.571.20E 27.597.003 28.422.002

Approval Holder:
Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg Hemer
Postcode
58675
Country
Germany
Phone
02372 930
General Email
marc.engelhardt@lixil.com

View All Listings by this Company

Print This Approval


#251104007

Shower handsets with chromium plated plastic bodies and a plastic flow regulator in the inlet. Maximum operating temperature 65°C. Open outlet use only.

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
251104007
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M).
Marking:
Flowpoint on body.
Installation Requirements:
R001 R040
Expiry date:
30/11/2030
Model:
S8015DG - Flowpoint.

Approval Holder:
Save Water Save Money Ltd
Company Name
Save Water Save Money Ltd
Address
International House 101 King’s Cross Road London
Postcode
WC1X 9LP
Country
United Kingdom
Phone
0345 371 0728
General Email
tim.robertson@savewatersavemoney.com

View All Listings by this Company

Print This Approval


#250912056

Range of in-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.

Section:
1715 Strainers
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1/2”, 3/4”, 1”, 1-1/4”, 1-1/2” & 2” BSP (F)
Marking:
ICV logo, size, pressure rating and flow arrow on body. ICV, WRAS & PN on data plate & label.
Installation Requirements:
R001
Expiry date:
30/09/2030
Model:
910/07
Product Images

Approval Holder:
IC Valves (Nanjing) Co.,Ltd.
Company Name
IC Valves (Nanjing) Co.,Ltd.
Address
Room 12A, Block A, Changfa Centre 300 East Zhongshan Rd, Nanjing ,Jiangsu Province
Country
China
General Email
Johnny.WYJ@icvalves.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2038 of 2060

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.