‘EPH_WSP19’ Range of brass bodied fittings for use with copper pipe, some fittings are to be soldered with copper pipe (see models). Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
“Plimat ABS Fittings BS Inch and ABS Adaptor Fittings” range of ABS solvent cement or threaded fittings for use with “Plimat ABS pipe”. Maximum working pressure: 15.0 bar (fittings with ½” - 4” solvent cement connections), 9.0 bar (fittings with 5” or 6” solvent cement connections, with or without threaded connecitons), and 10.0 bar (fittings with threaded connections and ½” - 4” solvent cement connections). Cold water and above ground use only.
Range of PSU, POM & DZR brass pushfit fittings for use with PE-x pipe (manufactured to BS7291-3), PB pipe (manufactured to BS7291-2) & copper pipe. Maximum working pressure 10.0 bar @ 65°C (PSU & DZR Brass Fittings). Open outlet use only @ 20°C (POM Fittings).
Range of press fittings incorporating copper or copper alloy bodies and EPDM O’-rings for use with copper tube to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of Flomasta brass pushfit fittings for use with PE-x pipe (manufactured to BS7291-3), PB pipe (manufactured to BS7291-2) & copper pipe. Maximum working pressure 10.0 bar @ 65°C (PSU & DZR Brass Fittings). Open outlet use only @ 20°C (POM Fittings).
Range of dual flush WC syphons incorporating a polypropylene body, stainless steel C link and a LDPE sealing washer. The valve is to be operated via a handle lever. Cold water use only.
Range of indirect heat interface units providing heating and instantaneous hot water. The hot water and space heating is provided via two separate plate heat exchangers. The space heating circuit incorporates an expansion vessel and expansion relief valve (set @ 3.0 bar). The primary circuit only is supplied with isolation valves on the flow and return. Maximum working pressure primary 16.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water (DHW) 10.0 bar. Maximum operating temperature primary 75°C. Maximum operating temperature space heating 85°C. Maximum operating temperature secondary hot water (DHW) 65°C.
Range of stainless-steel plate heat exchangers with copper brazing. Maximum working pressure 30.0 Bar. Maximum operating temperature 100°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.
Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.
Page 20 of 401
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.