Deck mounted, three hole, single outlet (fixed) combination tap assembly (brass body, various finish - see models) incorporating quarter turn ceramic disc headworks with single lever operating members. The product is supplied with a stainless steel braided thermoplastic silicone rubber lined flexible hose assemblies for installation between the headworks and the spout, a pop-up waste and metal backnuts. The spout outlet incorporates a combined plastic flow regulator and plastic aerator. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies. The product comprises of a trim set (chromium plated brass) and a concealed brass body. The concealed body incorporates two quarter turn ceramic disc headworks. The trim set includes a brass spout for installation into the concealed body, single lever operating members and a click type pop-up waste. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Self closing shower column with brass body (chrome plated), incorporating a push button flow control and adjustable shower outlet. Maximum working pressure 8.0 bar. Cold water use only.
Range of self closing shower column with brass body (chrome plated), incorporating a push button flow control and adjustable shower outlet. Maximum working pressure 8.0 bar. Cold water use only.
Range of combined bath fillers and overflow waste assemblies (plated brass covers and plastic hoses) with pop-up wastes. Maximum operating temperature 65ºC. Open outlet use only.
Range of wall mounted concealed installation kits with brass bodies. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Wall mounted spout outlet (brass body, various finishes - see model) incorporating a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of water filter heads and housings (sumps). The HIS/IN4 models have a chrome plated stainless steel filter head and housing, all other models have a plastic filter head and housing. Ecofast/IN3/QT models incorporate an integral quick turn shut off valve within the filter head to allow the filter housing to be removed. All models are for use with John Guest LLDPE pipe. Maximum working pressure 6.0 bar. Cold water use only.
A range of blue epoxy coated steel reverse rinsing fine filters with a stainless-steel sieve and an EDPM O-ring. Supplied with two pressure gauges and metal ball valve on the drain. Maximum working pressure 16 bar. Maximum operating temperature 40°C.
A range of water filter cartridges with polypropylene bodies. Maximum working pressure 8.6 bar. Cold water use only.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘AF’ range of compression fittings with brass or chrome plated brass bodies for use with copper pipe (manufactured to EN1057). The AF14 and AF15 tap connector models incorporate an EPDM washer. Maximum working pressure 16.0 bar. Maximum working temperature 85˚C
Range of tee fittings incorporating DZR brass bodies (chrome plated) and approved single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) for use with copper pipe to EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘Tectite Sprint’ range of pushfit fittings with copper or DZR brass bodies. 10mm, 15mm, 22mm & 28mm pushfit fittings are for use with copper pipe (manufactured to BS EN 1057) and polybutylene barrier pipe and cross linked PEX barrier pipe (manufactured to BS 7291). 35mm, 42mm & 54mm pushfit fittings are for use with copper pipe (manufactured to BS EN 1057) only. When used with PB & PEX pipes operating parameter are: 12.0 bar@cold water. 3.0 bar@92°C. When used with copper pipes operating parameter are: 20.0 bar@cold water. 10.0 bar@100°C.
Range of stainless-steel plate heat exchangers. Maximum operating pressures - primary circuit: 3.0 bar, secondary circuit (DHW): 10.0.bar. Maximum working temperature 80°C.
Under counter electric instantaneous water heater with a stainless steel tank. The flow is controlled via a solenoid valve. The product is supplied with a 3 way isolation valve (15mm compression x 15mm compression x ¾” BSP (M)), as well as a filter head and filter cartridge for installation prior to the under counter unit. LLDPE tubing and pushfit connections are provided for connecting between these items. The filter head inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet to the under counter unit incorporates a combined silicone washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.5 bar. Maximum operating temperature 98˚C. Cold water supply only.
Water meter incorporating a brass body and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of booster pumps with stainless steel bodies, plastic impellers, and NBR ‘O’-rings. The products incorporate a temperature sensor, pressure sensor, pressure vessel and a non-return valve integral to the pump chamber. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C.
Range of self-priming jet pumps with stainless steel bodies. Maximum working pressure 6.0 bar. Maximum operating temperature 45°C
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Page 182 of 554
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.