Range of single-hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The products are supplied with a surface mounting kit incorporating EPDM lined flexible hose assemblies with ½” captive nut and 15mm compression isolation valves that incorporate single check valve assembly (suitable for backflow protection against fluid category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of single-hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The products are supplied with a surface mounting kit incorporating EPDM lined flexible hose assemblies with ½” captive nut and 15mm compression isolation valves that incorporate single check valve assembly (suitable for backflow protection against fluid category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of single hole, single outlet, swivel, combination tap assemblies in various finishes. The models incorporate a ceramic cartridge headwork and a single lever operating member. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Single hole single outlet (swivel) combination tap assembly (brass body - various finishes), incorporating a ceramic cartridge headworks with single lever operating member. The spout outlet incorporates a plastic aerator and the product is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet fixed combination tap assembly (chrome plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. This product is supplied with metal backnuts. Maximum working pressure 10.0 Bar Maximum operating temperature 60°C.
Two-hole, single outlet, fixed, combination tap assembly, (chrome plated brass body), incorporating quarter turn ceramic disc headworks with single lever operating members. The products are supplied with metal back nuts. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of two-hole, single outlet fixed combination tap assemblies, incorporating quarter turn ceramic disc headworks with single lever headworks. The spout outlet incorporates a plastic aerator. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 60°C
Range of two hole, single outlet fixed combination tap assemblies (brass bodies – various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightner. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of two hole, single outlet fixed combination tap assemblies (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic aerators. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of two-hole, single outlet fixed combination tap assemblies (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporate a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of two hole, single outlet (fixed) combination tap assembly with brass body, incorporating quarter turn ceramic disc headworks with either single lever or cross top operating members. The spout outlet incorporates a plastic areator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a single sequential thermostatic cartridge controlling both flow and temperature with a single lever operating member. The spout outlets incorporate a plastic flow straightener The inlets incorporate a concentric isolation valve, stainless steel strainer and a plastic flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Two hole, single outlet fixed combination tap assembly (chromium plated brass), incorporating a single sequential thermostatic cartridge controlling both flow and temperature with a single lever operating member. The spout outlet incorporates a plastic aerator. The inlets incorporate a stainless steel strainer and a plastic flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes). Incorporating a ceramic cartridge headwork with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure; 10 Bar Maximum operating temperature 65°C
Range of two hole, metal, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener. The product is also supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of bath shower mixers with (chrome plated brass bodies). The products have a manual bath to shower diverter with a single lever operating member and quarter turn ceramic disc headworks with cross-top operating members. The product is supplied with a shower hose, handset, and metal backnuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator. The product is supplied with a shower hose and handset, and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with cross top operating members and a manually operated diverter to shower outlet with a single lever operating member. The products are supplied with a shower hose, handset and metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two-hole, single outlet, fixed combination tap assemblies, (brass bodies – various finishes), incorporating quarter turn cermic disc headworks with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator. The products are supplied with shower hoses, handsets and metal back nuts. Maximum working pressure 10 bar. Maximum operating temperature 60°C
Range of two-hole, single outlet, fixed combination tap assemblies, (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter. The spout outlets incorporate plastic flow straighteners. The products are supplied with a shower hose, handset and metal back nuts. Maximum working pressure 10 bar. Maximum operating temperature 60°C
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies, (brass bodies - various finishes), incorporating a ceramic cartridge headwork with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator. Both inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various models), incorporating quarter turn ceramic disc headworks with cross top or single lever operating members and a manually operated diverter to shower outlet. Maximum working pressure 5.0 Bar Maximum operating temperature 65.0°C
Range of two hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with either single lever, dome type or wheel operating members. The spout outlet incorporates a plastic aerator and the products are supplied with metal backnuts. Maximum working pressure; 10 Bar Maximum operating temperature 60°C
Range of two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The products are also supplied with metal backnuts. Maximum working pressure 8.62 Bar Maximum operating temperature 60.0°C
Range of wall mounted, two-hole, single outlet (swivel), combination tap assemblies (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spot outlet incorporates a plastic flow straightener. The offset unions of models 2445, 2445L, 2445EP & 2445LEP incorporate a concentric isolation valve. Model 2445EPS incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection and a flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Range of wall mounted, two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator, and the products are supplied with metal backnuts. Maximum working pressure 8.62 Bar Maximum operating temperature 60.0°C
Two-hole, single outlet, (fixed), combination tap assembly (chrome plated brass body), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a manual diverter to shower outlet. The product is supplied with a shower hose, handset and metal back nuts. Maximum working pressure 10 bar. Maximum operating temperature 75°C
Range of two-hole, single outlet (fixed) combination tap assemblies various finishes incorporating quarter turn ceramic disc headworks with various operating members and lockable diverter to shower outlet. The spout outlet incorporates a plastic aerator. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. temperature 60°C.
Range of wall mounted or floor standing spout outlets (fixed or swivel - see model in various finishes). All models incorporate a plastic flow straightener, except for the 93-Floor Mounted Bath Filler which has a plastic aerator.
Non-metallic materials and components comply with BS6920 at 60°C
Range of deck mounted spout outlets (fixed or swivel - see model, Various finishes) incorporating a plastic flow straightener. The products are supplied with metal backnuts.
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted spout outlets with (brass bodies - various finishes) incorporating a plastic aerator in the outlet. Open outlet use only. Maximum operating temperature 60.0°C
Range of spout outlets (brass bodies – various finishes) incorporating a plastic aerator. The product is also supplied with metal backnuts. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of filter cartridges. Maximum working pressure 8.0 Bar. Cold water use only.
Filter cartridge with a plastic body. Maximum working pressure 8.0 bar. Cold water use only.
Range of fohn stainless steel (SUS304/316L) crimp fittings incorporating EPDM ‘O’-rings. For use with FOHN stainless steel pipes (SUS304/316L). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of plastic compression fittings incorporating polypropylene bodies& plastic pipe liners.. For use with both PE80 & PE100 pipe manufactured to BS EN 12201. Maximum working pressure 16 Bar Maximum operating temperature 23°C
Range of ‘B’ Press XL copper crimped fittings with EPDM ‘O’-rings for use with copper pipe to BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper crimped fittings with EPDM ‘O’-rings for use with copper pipe manufactured to EN1057. For above and below ground use. Maximum working pressure 16 Bar. Maximum operating temperature 99°C.
Range of WC dual flush drop valves operated via a two-push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of wall mounted, electronic tap assemblies which are set within a mirrored cabinet unit. The flow is controlled by a solenoid valve assembly and is activated via infra-red non touch operation. The units also incorporate a soap dispenser and hand dryer or paper towel dispenser. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of copper or stainless-steel brazed heat exchangers available with various number of plates as listed below. Maximum working pressure 25.0 Bar (copper brazed models). Maximum working pressure 10.0 Bar (stainless steel brazed models). Maximum operating temperature 100.0°C.
Range of water meters with either cast iron (blue epoxy coated) or stainless-steel bodies, transducers and EPDM rubber O-rings. Maximum working pressure 25.0 Bar. Maximum operating temperature 50.0°C.
Range of in-line water meters with either a brass or plastic composite body. The product incorporates a plastic strainer on the inlet. Maximum working pressure 16.0 Bar Maximum operating temperature 85.0°C
Range of in-line water meters with brass bodies. The inlets incorporate a plastic filter. The outlets incorporate a non-return valve (not intended for or suitable for backflow protection). Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of in-line water meters with plastic bodies. The inlet incorporates a plastic filter. Maximum working pressure; 16 Bar Maximum operating temperature 50°C
Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of VEGAPULS radar sensors for level measurement with plastic bodies. Cold water use only. Open outlet use only.
Range of ‘Thermowatt’ immersion heater elements incorporating brass or DZR heads with either a copper, stainless steel, alloy or titanium heating element and a black EPDM ‘O’-ring. Open outlet use only. Maximum operating temperature 99°C
`Prox’ and ‘Wave` ranges of sensor operated flow control devices incorporating a normally closed solenoid valve to control the flow and operated via an infra-red sensor. The inlet incorporates a stainless-steel strainer. Maximum working pressure 8 Bar Maximum operating temperature 65°C
Range of positive displacement diaphragm pumps with plastic bodies, EPDM ‘O’-rings and TPE diaphragm. The product incorporates an integral bypass relief valve. For use with John Guest LLDPE Pipe. Maximum working pressure 12.0 Bar. Maximum operating temperature 40.0°C.
Page 181 of 225
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.