Range of CENTERSTORE AIR bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added March 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar. Maximum operating temperature 65°C.
Range of indirect unvented indoor heat pump storage cylinders which consist of a heat pump which sits on top of the tank and heats the hot water via refrigeration pipes which then heats the cylinder by being externally mounted around the cylinder. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressure 6.0 Bar (Secondary) Maximum operating temperature 55.0°C
Range of wall mounted, exposed, thermostatic shower mixing valves (chromium plated brass). The products incorporate a ¼ turn ceramic disc or a 2-way ceramic disc diverter headwork (see model). Temperature is controlled independently via a thermostatic cartridge with a manual override button. The products have cube (81B, 81C, 90B and 90C suffix models) dome type (all other models) operating members. Models (GR-LY-13BK2 & GR-LY-13BK4) incorporate single lever operating members. Each inlet incorporates a combined EPDM washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of wall mounted thermostatic shower valves (chrome plated brass). Flow is controlled by a ceramic disc diverter cartridge, using dome type operating members. Temperature is controlled independently via a thermostatic cartridge using a dome type operating member which also incorporates a manual override button. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted thermostatic shower valves (various finishes) incorporating a quarter turn ceramic disc headworks with single lever type operating members. The temperature is controlled independently via a thermostatic cartridge with manual override and single lever type operating members. Both inlets incorporate approved single check valve cartridges (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Wall mounted, bar type, thermostatic shower mixer (chromium plated brass), incorporating a 2-way ceramic disc diverter headwork with a dome type operating member controlling the flow between each shower outlet. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection The product is supplied with a shower hose (metal interlocked), shower handset (chrome plated), riser rail and overhead shower. The shower handset and the overhead shower both incorporate a stainless-steel strainer on the inlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, thermostatic shower valves with brass bodies (various finishes), incorporating a thermostatic cartridge controlling the temperature and a push shut-off valve controlling the flow. The inlets and the shower outlet incorporate approved check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Wall mounted, manually operated blending valve with a brass body (various finishes) and ceramic cartridge headwork a single lever operating member. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 70.0°C
Range of thermostatic shower panels incorporating a single sequential thermostatic control valve with a single lever operating member and flexible riser kit. Each inlet supplied with a servicing valve, EPDM o-ring and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Products are supplied with black lined PVC shower hoses and chrome plated shower handsets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of wall mounted concealed (BIV & BIR models) and exposed (EV model) thermostatic shower control valves. The bodies are cast brass (concealed versions) with a chromium plated trim set or chromium plated brass (exposed versions). Flow and temperature are controlled by a thermostatic cartridge with a single lever operating member. The inlets incorpoarate stainless steel strainers. Some models are supplied with a shower hose and handset or an overhead shower arm and shower head with flow regulator (see model section). The BIV model is also supplied with an angled wall outlet elbow. Maximum working pressure 5.0 bar. Maximum operating temperature 45°C.
Page 165 of 401
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.