#2306335

Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2075 Float Operated Inlet Valve
Section Subtitle:
Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
WRAS Approval Number:
2306335
Size:
55mm
Marking:
Toto, model code on body
Installation Requirements:
R001 R550 R573
Expiry date:
30/06/2028
Model:
B3230-D

Approval Holder:
TOTO Europe GmbH
Company Name
TOTO Europe GmbH
Address
Zollhof 2 40211 Düsseldorf Germany
Phone
+49 211 273080

View All Listings by this Company

Print This Approval


#240202705

Range of side or bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow regulator. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2075 Float Operated Inlet Valve
Section Subtitle:
Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
WRAS Approval Number:
240202705
Note:
IRN 560 applies to bottom entry model only.
Size:
1/2” BSP (M)
Marking:
ECOTECH, Model and BS1212-4 on body
Installation Requirements:
R001 R550 R560
Expiry date:
28/02/2029
Model:
B3015 – Side entry fill valve B3014 – Bottom entry fill valve

Approval Holder:
ECO (Xiamen) Technology INC.
Company Name
ECO (Xiamen) Technology INC.

View All Listings by this Company
Manufacturer:
ECO (Xiamen) Technology INC.
Company Name
ECO (Xiamen) Technology INC.

View All Listings by this Company

Print This Approval


#240801001

Range of BS1212-4 (2016) float operated valves for WC flushing cisterns, bottom or side entry type with plastic or brass ½’’ BSP inlet. The inlet incorporates a strainer, Compact models incorporate a delay fill function. Maximum working pressure 10.0 bar. For use with cold water only.

Section:
2075 Float Operated Inlet Valve
Section Subtitle:
Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
WRAS Approval Number:
240801001
Basis of Compliance:
Tested to a standard assessed as an appropriate British Standard by WRAS
Note:
IRN R560 applies to pedestal & telescopic valves only. IRN R562 applies to telescopic valves only.
Size:
½" BSP (M) inlet.
Marking:
Dudley BS1212/4 on front nut. Hydroflo and WRAS approved product on overhead discharge nozzle.
Installation Requirements:
R001 R550 R560 R562
Expiry date:
31/08/2029
Model:
Hydroflo Range Standard (Plastic or Brass Inlet): Hydroflo Side Inlet. Hydroflo Pedestal 8”, 8½”, 9”, 9½”, 10”, 10½”, 11”, 11½”, 12”. Hydroflo Compact Range Standard (Plastic or Brass Inlet): Hydroflo Side Inlet (Delayed Fill). Hydroflo Pedestal 8”, 8½”, 9”, 9½”, 10”, 10½”, 11”, 11½”, 12” (Delayed Fill). Hydroflo Range Enhanced (Plastic or Brass Inlet): Hydroflo Side Inlet. Hydroflo Pedestal 8”, 8½”, 9”, 9½”, 10”, 10½”, 11”, 11½”, 12”. Hydroflo Telescopic Hydroflo Compact Range Enhanced (Plastic or Brass Inlet): Hydroflo Side Inlet (Delayed Fill). Hydroflo Pedestal 8”, 8½”, 9”, 9½”, 10”, 10½”, 11”, 11½”, 12” (Delayed Fill). Hydroflo Telescopic (Delayed Fill). Hydroflo Range Flow Regulated (Plastic or Brass Inlet): Hydroflo Side Inlet. Hydroflo Pedestal 8”, 8½”, 9”, 9½”, 10”, 10½”, 11”, 11½”, 12”. Hydroflo Compact Range Flow Regulated (Plastic or Brass Inlet): Hydroflo Side Inlet (Delayed Fill). Hydroflo Pedestal 8”, 8½”, 9”, 9½”, 10”, 10½”, 11”, 11½”, 12” (Delayed Fill).

Approval Holder:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Postcode
DY1 4SJ
Country
United Kingdom
Phone
0121 530 7053
General Email
jcresswell@thomasdudley.co.uk

View All Listings by this Company
Manufacturer:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Postcode
DY1 4SJ
Country
United Kingdom
Phone
0121 530 7053
General Email
jcresswell@thomasdudley.co.uk

View All Listings by this Company

Print This Approval


#240202718

Range of side or bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow regulator. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2075 Float Operated Inlet Valve
Section Subtitle:
Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
WRAS Approval Number:
240202718
Note:
IRN 560 applies to bottom entry model only.
Size:
1/2” BSP (M)
Marking:
Flomasta, BS1212-4 & model on body
Installation Requirements:
R001 R550 R560
Expiry date:
28/02/2029
Model:
C10042207 – Side entry fill valve C10042206 – Bottom entry fill valve

Approval Holder:
Kingfisher International Products B.V
Company Name
Kingfisher International Products B.V
Address
Rapenburgerstraat 175E, 1011 VM Amsterdam
Country
Netherlands

View All Listings by this Company

Print This Approval


#240202719

Range of side or bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow regulator. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2075 Float Operated Inlet Valve
Section Subtitle:
Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
WRAS Approval Number:
240202719
Note:
IRN 560 applies to bottom entry model only.
Size:
1/2” BSP (M)
Marking:
Flomasta & Model on body.
Installation Requirements:
R001 R550 R560
Expiry date:
28/02/2029
Model:
C10042206 – Bottom entry fill valve C10042207 – Side entry fill valve

Approval Holder:
Kingfisher International Products Ltd
Company Name
Kingfisher International Products Ltd
Address
1 Paddington Square, London
Postcode
W2 1GG
Phone
07721 260713
General Email
eric.capotummino@kingfisher.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 15 of 41

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.