Directory Search Results

Print List

#250302052

Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass bodies). Flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
250302052
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M)
Marking:
Deva & DTC28 on tap body.
Installation Requirements:
R001 R006 R010
Expiry date:
31/03/2030
Model:
SENSOR7/D

Approval Holder:
Methven UK Limited
Company Name
Methven UK Limited
Address
Methven Experience Centre 3-3A Stone Cross Court Yew Tree Way Golborne Warrington
Postcode
WA3 3JE
Country
United Kingdom
Phone
0800 195 1602
General Email
raluca.olariu@uk.methven.com

View All Listings by this Company

Print This Approval


#250401701

WC Cistern incorporating a side or bottom entry float operated inlet valve and a dual flush Drop Valve (Acclaim V) or Syphon (Acclaim S) of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by lever or manual push button. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
250401701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP Male inlet connection.
Marking:
‘Cascade +’ or ‘Dudley Turbo’ on syphon. ‘Dudley’ and ‘TD’ on drop valve ‘HYDROFLO’.‘DUDLEY BS 1212/4’ inlet valve, Thomas Dudley Ltd on cistern. 6 litre line inside cistern
Installation Requirements:
R001 R280 R556
Expiry date:
30/04/2030
Model:
Acclaim V & Acclaim S.

Approval Holder:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Postcode
DY1 4SJ
Country
United Kingdom
Phone
0121 530 7053
General Email
jcresswell@thomasdudley.co.uk

View All Listings by this Company
Manufacturer:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Postcode
DY1 4SJ
Country
United Kingdom
Phone
0121 530 7053
General Email
jcresswell@thomasdudley.co.uk

View All Listings by this Company

Print This Approval


#250303303

Section:
1670 Shower Outlets
Description:
A Range of Shower kit(s)
Hose retainer
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Installation Requirements:
R001 R040
Expiry date:
31/03/2030

Product IdentificationSurface finishInlet DimensionMax Wrk. PressureMax Op. Temp.MarkingMarking LocationAll metals in the water pathway are on the 4msi positive listHeadworkFixing TypeSpout Outlet Includes
FLKIT40 CChrome1/2" BSPOpen Outlet bar60 °CBristanHandsetNoNot applicableNot ApplicableNot ApplicableFlow Regulator Fitted, Shower Hose, Handset, Riser Rail,
FLKIT60 CChrome1/2" BSPOpen Outlet bar60 °CBristan HandsetNoNot applicableNot ApplicableNot ApplicableFlow Regulator Fitted, Shower Hose, Handset, Riser Rail,
FLKIT80 CChrome1/2" BSPOpen Outlet bar60 °CBristanHandsetNoNot applicableNot ApplicableNot ApplicableFlow Regulator Fitted, Shower Hose, Handset, Riser Rail,
Product Images

Approval Holder:
Bristan Group Ltd.
Company Name
Bristan Group Ltd.
Address
Birch Coppice Business Park Dorden Tamworth
Postcode
B78 1SG
Country
United Kingdom
Phone
01827 254144
General Email
hmistry@bristan.com

View All Listings by this Company

Print This Approval


#250488701

Spring loaded, resilient trim, in-line check valve cartridges with plastic guide, stem and body. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.

Section:
0026 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Check Valve Cartridge. The cartridges listed in this section are for factory installation only and are not suitable for on-site installation.
WRAS Approval Number:
250488701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DN15
Marking:
Neoperl name & logo, DW20, DVGW, WRAS, flow arrow, DN15 on body.
Installation Requirements:
R001
Expiry date:
30/04/2030
Model:
DW20/DN15-1T 30.4073.0 Model added May 2025: DW20/DN15-EPDM 30.4075.0.

Approval Holder:
Neoperl GmbH
Company Name
Neoperl GmbH
Address
Klosterrunstrasse 9-11, Müllheim
Postcode
D-79379
Country
Germany
Phone
+49 7631 188 374
General Email
DE.Approvals@neoperl.com

View All Listings by this Company
Manufacturer:
Neoperl GmbH
Company Name
Neoperl GmbH
Address
Klosterrunstrasse 9-11, Müllheim
Postcode
D-79379
Country
Germany
Phone
+49 7631 188 374
General Email
DE.Approvals@neoperl.com

View All Listings by this Company

Print This Approval


#250404703

Spring loaded resilient trim check valve cartridge with plastic body and EPDM ‘O’-rings. For insertion into fittings with specifically sized bores. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.

Section:
0026 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Check Valve Cartridge. The cartridges listed in this section are for factory installation only and are not suitable for on-site installation.
WRAS Approval Number:
250404703
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DN15
Marking:
Watts logo & DN15 on body.
Installation Requirements:
R001
Expiry date:
30/04/2030
Model:
149B040135 Type TK model IO

Approval Holder:
Socla SAS
Company Name
Socla SAS
Address
365, Rue du Lt Putier, 71530 Virey Le Grand, France
Phone
+33 3 85 97 42 42

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1346 of 1771

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.