Directory Search Results

Print List

#240502713

Range of dual flush WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not been verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
240502713
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
2” BSP (M)
Marking:
Anboly and model number on base of flush body.
Installation Requirements:
R001 R571 R581
Expiry date:
31/05/2029
Model:
ABL-3009 ABL-5008

Approval Holder:
GUANGDONG ANBOLY SANITARY TECHNOLOGY CO ., LTD
Company Name
GUANGDONG ANBOLY SANITARY TECHNOLOGY CO ., LTD
Address
Weichi Park, Huangcuowei Village, Dongfeng Town, Chao’an District, Chaozhou City, Guangdong Province
Country
China
Phone
+86 0768-5388845
General Email
annie_lu0515@163.com

View All Listings by this Company
Manufacturer:
GUANGDONG ANBOLY SANITARY TECHNOLOGY CO ., LTD
Company Name
GUANGDONG ANBOLY SANITARY TECHNOLOGY CO ., LTD
Address
Weichi Park, Huangcuowei Village, Dongfeng Town, Chao’an District, Chaozhou City, Guangdong Province
Country
China
Phone
+86 0768-5388845
General Email
annie_lu0515@163.com

View All Listings by this Company

Print This Approval


#240504714

Range of direct gas fired condensing storage water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.

Section:
1400 Heaters
Section Subtitle:
Gas fired, closed outlet. Heat retained in water heaters may cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to prevent excess pressure within the system.
WRAS Approval Number:
240504714
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Please refer to model.
Marking:
Company logo (A.O. Smith), model and technical information on body
Installation Requirements:
R001 R140
Expiry date:
31/05/2029
Model:
BFC 28, BFC 30, BFC 50, BFC 60, BFC 80, BFC 100, BFC 120, SGS 28, SGS 30,SGS 50, SGS 60, SGS 80, SGS 100 & SGS 120

Approval Holder:
A.O.Smith Water Products Company B.V.
Company Name
A.O.Smith Water Products Company B.V.
Address
De Run 5305 Veldhoven
Postcode
5503 LW
Country
Netherlands
Phone
+31 (0) 40 294 2560
General Email
hmichiels@aosmith.com

View All Listings by this Company
Manufacturer:
A.O.Smith Water Products Company B.V.
Company Name
A.O.Smith Water Products Company B.V.
Address
De Run 5305 Veldhoven
Postcode
5503 LW
Country
Netherlands
Phone
+31 (0) 40 294 2560
General Email
hmichiels@aosmith.com

View All Listings by this Company

Print This Approval


#240504716

Range of indirect water heaters with an enamel lining, a magnesium sacrificial anode and single wall spiral heat exchanger (maximum working pressure 6.0 bar). Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 7.0 bar. Maximum operating temperature 80°C

Section:
1400 Heaters
Section Subtitle:
Gas fired, closed outlet. Heat retained in water heaters may cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to prevent excess pressure within the system.
WRAS Approval Number:
240504716
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
¾” BSP (F)
Marking:
Company logo (AO Smith), model and technical information on body.
Installation Requirements:
R001 R140
Expiry date:
31/05/2029
Model:
IT 1500, IT 2000, IT 2500, IT 3000, ST 1500, ST 2000, ST 2500 & ST 3000

Approval Holder:
A.O.Smith Water Products Company B.V.
Company Name
A.O.Smith Water Products Company B.V.
Address
De Run 5305 Veldhoven
Postcode
5503 LW
Country
Netherlands
Phone
+31 (0) 40 294 2560
General Email
hmichiels@aosmith.com

View All Listings by this Company
Manufacturer:
A.O.Smith Water Products Company B.V.
Company Name
A.O.Smith Water Products Company B.V.
Address
De Run 5305 Veldhoven
Postcode
5503 LW
Country
Netherlands
Phone
+31 (0) 40 294 2560
General Email
hmichiels@aosmith.com

View All Listings by this Company

Print This Approval


#240504718

Range of glass enamel lined direct water heaters fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.

Section:
1400 Heaters
Section Subtitle:
Gas fired, closed outlet. Heat retained in water heaters may cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to prevent excess pressure within the system.
WRAS Approval Number:
240504718
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1½” BSP (M)
Marking:
Company logo (AO Smith), model and technical information on body.
Installation Requirements:
R001 R140
Expiry date:
31/05/2029
Model:
IT 300, IT 400, IT 500, IT 600, IT 750, IT 1000, ITE 400, ITE 500, ITE 600, ITE 750, ITE 1000, ITS 300, ITS 400, ITS 500, ITS 600, ITS 750, ITS 1000, ST 300, ST 400, ST 500, ST 600, ST 750 & ST 1000

Approval Holder:
A.O.Smith Water Products Company B.V.
Company Name
A.O.Smith Water Products Company B.V.
Address
De Run 5305 Veldhoven
Postcode
5503 LW
Country
Netherlands
Phone
+31 (0) 40 294 2560
General Email
hmichiels@aosmith.com

View All Listings by this Company
Manufacturer:
A.O.Smith Water Products Company B.V.
Company Name
A.O.Smith Water Products Company B.V.
Address
De Run 5305 Veldhoven
Postcode
5503 LW
Country
Netherlands
Phone
+31 (0) 40 294 2560
General Email
hmichiels@aosmith.com

View All Listings by this Company

Print This Approval


#240502715

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with isolation valve on both the DHW and CH circuits. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel strainer. Some models (see model section) are supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressures: DHW: 10.0 Bar CH: 2.5 Bar Maximum operating temperature: DHW: 65.0°C CH: 85.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240502715
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DHW: 15mm compression. CH: 22mm compression
Marking:
Range name on front cover, Model, Max pressure, Max temperature and product information on data plate on body
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2029
Model:
Models without a filing loop supplied: 0010016113 - Glow-worm ESSENTIAL 24c -A (H-GB) 0010016115 - Glow-worm ESSENTIAL 28c -A (H-GB) 0010016127 - Heatline CAPRIZ 2 24c -A (H-GB) 0010016128 - Heatline MONZA 2 24c -A (H-GB) 0010016129 - Heatline CAPRIZ 2 28c -A (H-GB) 0010016130 - Heatline MONZA 2 28c -A (H-GB) 0010021401 - Glow-worm EASICOM 3 24c -A (H-GB) 0010021402 - Glow-worm EASICOM 3 28c -A (H-GB) 0010020392 - Vaillant VUW 256/6-3 (H-GB) ecoFIT sustain 825 0010020393 - Vaillant VUW 306/6-3 (H-GB) ecoFIT sustain 830 0010020394 - Vaillant VUW 356/6-3 (H-GB) ecoFITsustain 835 Models with a filling loop supplied: 0010020389 - Vaillant VUW 256/6-3 (H-GB) ecoFIT pure 825 0010020390 - Vaillant VUW 306/6-3 (H-GB) ecoFIT pure 830 0010020391 - Vaillant VUW 356/6-3 (H-GB) ecoFIT pure 835 0010019813 - Vaillant VUW 306/6-3 (P-GB) ecoFIT pure 830 P 0010021204 - Glow-worm BETACOM 4 24c -A (H-GB) 0010021205 - Glow-worm BETACOM 4 30c -A (H-GB) 0010021404 - Glow-worm ULTIMATE 3 30c -A (H-GB) 0010021405 - Glow-worm ULTIMATE 3 35c -A (H-GB) 0010027591 - Glow-worm ENERGY 2 30c -A (P-GB) 0010035896 - Glow-worm ENERGY 7 25c (H-GB) 0010035897 - Glow-worm ENERGY 7 30c (H-GB) 0010035898 - Glow-worm ENERGY 7 35c (H-GB)

Approval Holder:
Vaillant GmbH
Company Name
Vaillant GmbH
Address
Berghauser Strasse, 40 D-42859 Remscheid
Country
Germany
Phone
Tel: +49 2191 182126

View All Listings by this Company

Print This Approval


#240502720

Range of wall mounted combination boilers providing domestic hot water (DHW) via a plate heat exchanger and pressurised central heating (CH) system. Incorporating a pressure relief valve set at 3.0 bar and expansion vessel. Supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressure Primary circuit (CH) 2.5Bar, Secondary circuit (DHW) 10.0 Bar Maximum operating temperature 90.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240502720
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Primary circuit (CH) ¾” BSP (M), Secondary circuit (DHW) ½” BSP (M).
Marking:
NAVIEN on front of boiler. NAVIEN, Model Number, Max Pressure and other technical info on adhesive label on body
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2029
Model:
NCB300-28K NCB300-37K NCB300-41K Model added July 2024 NCB300-30K

Approval Holder:
KD Navien Co Ltd
Company Name
KD Navien Co Ltd
Address
4F Koami Bldg, 22 Gukhoe daero, 76-gil, Yeongdeungpo-gu, Seoul, 07238 Korea
Phone
+82 2 3489 2200
General Email
www.navien.com

View All Listings by this Company
Manufacturer:
KD Navien Co Ltd
Company Name
KD Navien Co Ltd
Address
4F Koami Bldg, 22 Gukhoe daero, 76-gil, Yeongdeungpo-gu, Seoul, 07238 Korea
Phone
+82 2 3489 2200
General Email
www.navien.com

View All Listings by this Company

Print This Approval


#240402055

Range of water meters with black epoxy coating bodies, plastic impellers and EPDM ‘O’ rings. Maximum working pressure – 16.0 Bar. Cold water use only.

Section:
1505 Water Meters
Size:
DN50 to DN100 flanged inlet and outlet.
Marking:
Wesan, Diel Metering GmbH and product info on meter face. Wesan logo on meter face cover. Flow arrow and size on side of body.
Installation Requirements:
R001
Expiry date:
30/04/2029
Model:
WESAN WS G DN50/270 DN65/300 DN80/350 DN100/350

Approval Holder:
Diehl Metering GmbH
Company Name
Diehl Metering GmbH
Address
Industriestrasse 13/Am Weimarer Berg 3, 91522 Ansbach/99510 Apolda
Country
Germany

View All Listings by this Company
Manufacturer:
Diehl Metering GmbH
Company Name
Diehl Metering GmbH
Address
Industriestrasse 13/Am Weimarer Berg 3, 91522 Ansbach/99510 Apolda
Country
Germany

View All Listings by this Company

Print This Approval


#240404044

Ultrims Ultrasonic range of in-line water meters with brass or plastic (-01 suffix models) bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.

Section:
1505 Water Meters
Size:
UL 2.5 & UL 2.5-01 models: ¾” BSP (M). UL 4 & UL 4-01 models: 1” BSP (M). UL 6,3 model: 1¼” BSP (M). UL 25 model: DN50 flanged connection.
Marking:
Powogaz logo, manufacturer’s address and year (YYYY), CE Mark, meter type and other technical information on meter face. Flow arrow on body.
Installation Requirements:
R001
Expiry date:
30/04/2029
Model:
Ultrims range: UL 2.5 (port lengths 80, 110 & 165mm), UL 2.5-01 (port lengths 80 & 110mm), UL 4 (port lengths 105, 115, 130 & 190mm), UL 4-01 (port lengths 105 & 130mm), UL 6.3 (port lengths 165 & 260mm), UL 25 (port lengths 200, 270 & 300mm). Models added November 2024: Ultrims Range: UL10 (port length 260mm) UL16 (port length 300mm) Ultrims Neo Range: ULN2.5 (port lengths 80, 110, 115 & 165mm) ULN2.5-01 (port lengths 80, 110 & 165mm) ULN4 (port lengths 105, 115, 130 & 190mm) ULN4-01 (port lengths 105, 115 & 130mm) Models Added April 2025: Ultrimis Neo 6,3 Ultrasonic water meter with brass body. DN25 - Body length [mm]: 165, 260 - G1 ¼ B. Ultrimis Neo 10 Ultrasonic water meter with brass body. DN32 - Body length [mm]: 260 - G1 ½ B Ultrimis Neo 16 Ultrasonic water meter with brass body. DN40 - Body length [mm]: 300 - G2 B Ultrimis Neo 25 Ultrasonic water meter with brass body. DN50 - Body length [mm]: 200, 270, 300 – flanged.

Approval Holder:
Apator Powogaz S.A.
Company Name
Apator Powogaz S.A.
Address
Jaryszki 1C, 62-023 Żerniki
Country
Poland
Phone
+48 789 454 593
General Email
przemyslaw.gretka@apator.com

View All Listings by this Company
Manufacturer:
Apator Powogaz S.A.
Company Name
Apator Powogaz S.A.
Address
Jaryszki 1C, 62-023 Żerniki
Country
Poland
Phone
+48 789 454 593
General Email
przemyslaw.gretka@apator.com

View All Listings by this Company

Print This Approval


#240502040

Range of in-line and concentric water meters with composite bodies, TPE gasket and NBR ‘O’-ring(s). The products have an integral plastic filter. The inlet of the in-line models includes a non-return valve. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
JV600 Q3=2,5 R***: ¾” BSP (M). JV600 Q3=4 R***: 1” BSP (M). JV600 Q3=6,3 R***: 1¼” BSP (M). JV600 Q3=2,5 Concentric R***: ¾” BSP (M). JV600e Q3=2,5 R*** 3/4” BSP (M) JV600e Q3=2,5 Concentric R*** 3/4” BSP (M) JV600e Q3=4 R*** 1” BSP (M) JV600e Q3=6,3 R*** 1 1/4” BSP (M)
Marking:
Janz logo, maximum pressure, CE and other technical information on cover.
Installation Requirements:
R001
Expiry date:
31/05/2029
Model:
In-line water meter: JV600 Q3=2,5 R***. JV600 Q3=4 R***. JV600 Q3=6,3 R***. Concentric water meter: JV600 Q3=2,5 Concentric R***. Models added October 2024 JV600e Q3=2,5 R*** JV600e Q3=2,5 Concentric R*** JV600e Q3=4 R*** JV600e Q3=6,3 R*** Where *** relates to Class of Accuracy of the water meter and can be replaced by: 40, 50, 63, 80, 100, 125, 160, 200, 250, 315, 4100, 500, 630, 800.

Approval Holder:
Janz Contagem e Gestão de Fluidos, SA
Company Name
Janz Contagem e Gestão de Fluidos, SA
Address
Av. Infante D. Henrique nº 286 Lisboa
Postcode
1950-421
Country
Portugal
Phone
00351 21 831 6000
General Email
lbras@janz.pt

View All Listings by this Company
Manufacturer:
Janz Contagem e Gestão de Fluidos, SA
Company Name
Janz Contagem e Gestão de Fluidos, SA
Address
Av. Infante D. Henrique nº 286 Lisboa
Postcode
1950-421
Country
Portugal
Phone
00351 21 831 6000
General Email
lbras@janz.pt

View All Listings by this Company

Print This Approval


#240502041

Range of water meters with brass bodies, plastic turbines and plastic strainers on inlets. The products have an integral plastic filter. The inlet includes a non-return valve. Maximum working pressure 16.0 Bar Maximum operating temperature 23.0°C

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
¾” BSP M
Marking:
JANZ logo, Max working pressure, model code, CE and other technical information on meter face
Installation Requirements:
R001
Expiry date:
31/05/2029
Model:
JV400 Q3=2,5 R***, JV400 Q3=2,5 Concentric R***, JV400 Q3=4 R***, JV400 Q3=6,3 R***, JV400 Q3=10 R*** & JV400 Q3=16 R***. Models added October 2024 JV400e Q3=2,5 R*** JV400e Q3=2,5 Concentric R*** JV400e Q3=4 R*** JV400e Q3=6,3 R*** JV400e Q3=10 R*** JV400e Q3=16 R*** Where *** relates to Class of Accuracy of the water meter and can be replaced by: 40, 50, 63, 80, 100, 125, 160, 200, 250, 315, 4100, 500, 630, 800.

Approval Holder:
Janz Contagem e Gestão de Fluidos, SA
Company Name
Janz Contagem e Gestão de Fluidos, SA
Address
Av. Infante D. Henrique nº 286 Lisboa
Postcode
1950-421
Country
Portugal
Phone
00351 21 831 6000
General Email
lbras@janz.pt

View All Listings by this Company
Manufacturer:
Janz Contagem e Gestão de Fluidos, SA
Company Name
Janz Contagem e Gestão de Fluidos, SA
Address
Av. Infante D. Henrique nº 286 Lisboa
Postcode
1950-421
Country
Portugal
Phone
00351 21 831 6000
General Email
lbras@janz.pt

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 116 of 226

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.