Range of single hole, single outlet (fixed) combination tap assemblies (various finishes - see model). Electronic controls on the left-hand side of the body allow the tap to dispense one or more of the following (model specification dependent): boiling, chilled or sparkling water. Ambient (hot and cold) water is controlled via a ceramic cartridge headwork with a single lever operating member. The spout incorporates a plastic aerator on the Sparkling/Chilled and the Ambient outlet, and a separate outlet for the boiling water. Both model ranges incorporate a vent outlet within the tap spout for the boiling water circuit. Maximum working pressure 5.0 bar (Ambient (hot and cold) circuit only). 95458xxx models - Boiling circuit has a maximum operating temperature of 100°C. All other circuits have a maximum operating temperature of 65°C. 95459xxx models - Boiling circuit has a maximum operating temperature of 100°C. The ambient circuit has a maximum operating temperature of 65°C. The chilled/sparkling circuit has a maximum operating temperature of 60°C.
Range of single hole, double outlet (swivel) combination tap assemblies (various finishes) with electronically controlled functions to allow the tap to dispense boiling water, chilled water or sparkling water from under counter units (not supplied or part of this approval) and a ceramic cartridge headwork with single lever operating member controlling the flow of normal mixed water. The spout outlet incorporates a plastic aerator. Maximum working pressure: 5.0 Bar. Maximum operating temperature: 98.0°C.
Tudor range of above and under sink range of electrically heated vented water heaters (cased and insulated) incorporating an angle valve on the inlet for flow control. Maximum working pressure 3.5 bar. Maximum operating temperature 75°C.
Range of installation kits comprising of a water block, double check valve assembly (suitable for backflow protection against fluid category 3) and a pressure reducing valve (outlet pressure range 3.0 to 3.5 bar). Model 95428 incorporates a water filter. Maximum working pressure: 16 Bar Maximum operating temperature: 23°C
‘Zip Aquapoint IV’ range of wall mounted directly heated unvented storage vessels (cased and insulated) incorporating an enamel lined cylinder and safety kit. The cylinder is factory fitted with a temperature and pressure relief valve (7.0 bar/90°C) and a drain valve. The product is supplied with an installation kit comprising of an expansion vessel, tundish and an inlet manifold incorporating a 6.0 bar expansion relief valve, an adjustable pressure reducing valve with stainless-steel strainer (adjustable between 2.7 and 3.3 bar, but pre-set at 3.0 bar), and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The compression connections of the installation kit are for use with copper pipe (Manufactured to EN 1057). Maximum working pressure 5.5 bar. Maximum operating temperature 70°C. Cold supply only.
Page 4 of 4
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.