Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated or matt black brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Model 1002137653_N199998998 is supplied with a pop up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (in black or chrome finishes) with brass bodies. Incorporating ceramic cartridge headworks, and single lever operating members. The spout outlet incorporates a plastic aerator. Some models are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic shower mixer incorporating a chromium plated brass body and ceramic disc headwork with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with dome type operating member which has a manual override button. The inlets incorporate a single check valve cartridge (however the complete assembly has not been tested to demonstrate they provide adequate backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 90°C.
Range of shower arms and brackets with brass bodies (various finishes). Shower brackets incorporate single check valves cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum operating temperature 85°C.
Range of overhead shower outlets incorporating brass bodies (chrome plated) and EPDM gaskets. Inlets have stainless filters incorporated within a ball joint. Maximum operating temperature 85°C
Range of shower outlets and shower handsets. The shower heads have a brass body and ball joint, NBR ‘O’-ring, stainless-steel strainer and silicon nozzles. The shower handset has a brass body, NBR ‘O’-rings, silicon nozzles and incorporate a plastic flow regulator on the inlet. Model ‘100274774 N200000068’ is supplied with a double interlocked hose and a single check valve cartridge (to be installed on the inlet to the hose) however the complete product has not been fully tested to demonstrate it provides backflow protection. Model ‘100274774 N200000068’ has a maximum operating temperature of 60°C. All other models have a maximum operating temperature of 85°C.
Range of single hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes), ceramic cartridge headworks with single lever operating members. The spout outlets incorporates a plastic aerator. Models 100121306, 100121305 & 100123629 are supplied with lever operated pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of WC flushing cisterns incorporating a BS 1212-4 (2016) side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres or 4.5/3 litre flush volumes. The cistern is operated by a manual push button and the product incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar. Cold water use only.
Range of combined bath filler and overflow waste assemblies incorporating a cable operated pop-up waste. The outlet incorporates a plastic flow straightener. Maximum operating temperature 60°C.
Range of concealed, wall mounted thermostatic blending valves with brass bodies (chromium plated trim set). The product incorporates a ¼ turn ceramic disc or a 2 way manual diverter with shut-off position to control the flow, with dome type operating members.The temperature is controlled independently via thermostatic cartridges, with dome type operating members. The inlets incorporate approved check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure: 5 Bar. Maximum operating temperature: 60°C.
Range of WC flushing cisterns incorporating a BS 1212-4 (2016) side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres or 4.5/3 litre flush volumes. The cistern is operated by a manual push button and the product incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of shower outlets with plastic bodies (various finishes). Model 100184782 has flow regulator at the inlet and a shower arm. Maximum working pressure: open outlet. Maximum operating temperature: 70°C.
Range of shower kits comprising of ABS bodied shower handsets and PVC multi-layer hoses incorporating EPDM ‘O’-rings. Supplied with riser rail. Available in various finishes. Maximum operating temperature 60°C
Page of 1
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.