Combined bath filler and overflow waste assembly incorporating a click type pop-up waste.
Non-metallic materials and components comply with BS6920 at 65°C
Concealed WC dual flushing cistern with a bottom entry BS 1212 - 4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar, cold water use only.
Range of concealed WC dual flushing cisterns with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10 Bar, cold water use only.
Range of deck mounted, four hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a 2-way ceramic disc diverter headwork controlling the flow between the spout and shower outlet. Temperature is controlled independently by a thermostatic cartridge. The ARR-132T-CP model has single lever operating members and the ARR-232T-CP model has cross top operating members. Each inlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. The product is supplied with a shower hose and handset, and has metal backnuts. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks, and single lever operating members. The spout outlet incorporates a plastic aerator and some of the products are supplied with click type pop-up wastes. Maximum working pressure 10.0 bar. Maximum operating temperature 90⁰C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating ceramic cartridge or quarter turn ceramic discs headworks and dome or lever operating members. The spout outlets incorporate plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted two-hole, single outlet fixed combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with dome or lever type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60⁰C.
Range of overhead shower outlets with (brass bodies – various finishes) incorporating stainless-steel filter washers at the inlet. Maximum operating temperature 85°C.
Range of deck mounted; two-hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes - see model) incorporating quarter turn ceramic disc headworks with dome type (CAM-137-XXX models) or single lever (all other models) operating members. The spout outlet of the EDI-137-CP & IND-ED137-XXX models incorporates a plastic aerator, all other models incorporate a plastic flow straightener. The products are supplied with brass back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Deck mounted; two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with brass back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Multi-layer PVC shower hoses with silver coating, brass end connections, EPDM gasket and NBR ‘O’-ring. Open outlet use only. Maximum operating temperature 65°C
Single hole, single outlet (swivel) combination tap assembly (plated brass), incorporating ceramic cartridge headwork with dome type operating member, located at the end of the spout. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic shower valves (plated brass bodies), incorporating ceramic disc headworks controlling the flow and a thermostatic cartridge independently controlling the temperature, both using dome type operating members. Both inlets incorporate single check valve cartridges (however, the complete product has not been fully tested to demonstrate that it provides adequate backflow protection) and metal strainers. Spout outlets incorporate plastic flow straighteners. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted shower valve (various finishes) incorporating a quarter turn ceramic disc headwork controlling flow on/off and to either the overhead shower or the handset (CAM-149T-RRK-XXX). Temperature is controlled via a thermostatic cartridge with a manual override button. The inlets incorporate approved check valve cartridges; however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure: 5bar. Maximum operating temperature: 60°C.
Range of shower outlets and accessories with brass and plastic bodies (various finishes). Overhead shower inlets incorporate stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60⁰C.
Deck mounted, two-hole single outlet (brass bodies – various finishes), incorporating ceramic disc headwork controlling the flow from spout outlet to shower outlet and a thermostatic cartridge independently controlling the temperature, both using dome type operating members. Both inlets incorporate stainless steel strainers and approved single check valve cartridges (however, the complete product has not been fully tested to demonstrate that it provides adequate backflow protection). The spout outlet is fitted with a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Page 4 of 4
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.