Hattersley Approvals


#1909701

Range of drain taps with bronze bodies, EPDM seat and `O`-rings with a rising spindle headwork. Maximum working pressure 16.0 Bar, Maximum operating temperature 85°C

Section:
1770 Taps
Section Subtitle:
Draining, metal or plastic - For above ground use only.
WRAS Approval Number:
1909701
Expiry date:
30/06/2024
Size:
½”, ¾” & 1” BSP (M)
Marking:
371: Hattersley on body. 370: Hattersley logo (Stork – please see image) on body.
Installation Requirements:
R001 R511
Model:
Fig 370 & Fig 371
Factor:
Hattersley
Company Name
Hattersley
Address
Crane House, Epsilon Terrace, West Road, Ipswich
Postcode
IP3 9FJ

View All Listings by this Company

Print This Approval


#1907065

Range of spherical valves with DZR brass bodies, chrome plated brass balls, EPDM ‘O’-rings and PTFE seat. Above ground use only. Threaded ends: maximum working pressure 25.0 bar. Compression ends: maximum working pressure 16.0 bar. Press-fit ends: maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
2260 Valves
Section Subtitle:
Spherical, metal.
WRAS Approval Number:
1907065
Expiry date:
31/07/2024
Note:
R511 applies to the hose union models added July 2021
Size:
SEE MODEL
Marking:
HATTERSLEY, MODEL, PN & TECHNICAL INFORMATION ON OPERATING MEMBER Models added July 2021: HNH, WRAS temperature and max. temperature on cap. DN, PN, CR and size on body.
Installation Requirements:
R001 R511
Model:
Hattersley Fig 100 & 100EXT: ¼” – 2” BSP. Hattersley Fig 100T & 100LS: ½” – 2” BSP. Hattersley Fig 100.AT & 100EXT.AT: ¼” – 2” ANSI. Hattersley Fig 100T.AT & 100LS.AT: ½” – 2” ANSI. Hattersley Fig 100C, 100CEXT, 100CT & 100CLS: 15mm compression and 54mm compression only. Hattersley Fig 100.PF, 100LS.PF, 100EXT.PF & 100T.PF: Press fit ends 1/2" x 15mm, 1/2" x 18mm, 3/4" x 22mm, 1" x 28mm, 1.1/4" x 35mm, 1.1/2" x 42mm, 2" x 54mm. Press fit connections for use with the following piping: BS EN1057 - R250 copper 15mm-28mm, Geberit Mapress Stainless Steel 15mm-54mm & Geberit Mapress Carbon Steel 15mm-54mm Compression Fit connections for use with copper pipe to BS EN1057 R250. Above ground application for all Fig 100 Variants LS denotes lockshield model. EXT denotes extended stem. C/CT denotes tee handle. .PF denotes pressfit. .AT suffix denotes American Thread From May 2020 the following modification has been made: All threaded variants of this approval now have an increased wall thickness. Models added July 2021: Hattersley Fig 100HU: ½” BSP (M) x 15mm Hose Union. ¾” BSP (M) x 18mm Hose Union 1” BSP (M) x 22mm Hose Union
Factor:
Hattersley
Company Name
Hattersley
Address
Crane House, Epsilon Terrace, West Road, Ipswich
Postcode
IP3 9FJ

View All Listings by this Company

Print This Approval


#1910704

Range of Hattersley `Y`-patterned strainers with bronze bodies incorporating a stainless steel mesh strainer and PTFE washers. The FIG 817.PF models incorporate copper threaded x push fit end connections incorporating butyl rubber ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1715 Strainers
WRAS Approval Number:
1910704
Expiry date:
31/10/2024
Size:
See model.
Marking:
HNH, size, PN and flow arrow on body. HATETRSLEY, WRAS, temperature, max temperature/pressure and other technical info on strainer cap.
Installation Requirements:
R001 R120
Model:
"Y'-PATTERNED STRAINERS FIG 817: ½” - 2” BSP (F) TAPER. FIG 817.AT (THREADED): ½” - 2” ANSI B1.20.1 FIG 817.PF: 15MM - 54MM PRESS FIT INLET/OUTLET CONNECTIONS FOR USE WITH COPPER OR GEBERIT MAPRESS STAINLESS STEEL PIPE."
Factor:
Hattersley
Company Name
Hattersley
Address
Crane House, Epsilon Terrace, West Road, Ipswich
Postcode
IP3 9FJ

View All Listings by this Company

Print This Approval


#1908818

Range of globe type spring loaded, resilient trim, non-return valves with cast iron bodies (blue epoxy powder coated) with stainless steel springs and guides. Maximum working pressure 16.0 bar. The maximum operating temperature is 85°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
1908818
Expiry date:
31/08/2024
Size:
See Model
Marking:
HATTERSLEY, PN, MAXIMUM TEMPERATURE, WRAS & FIG 160W ON DATAPLATE ON BODY DN, PN, HATTERSLEY, WRAS, FLOW ARROW, EN & PRODUCTION DATE YY/MM/DD ON BODY
Installation Requirements:
R001
Model:
FIG160W: DN50 - DN300.
Factor:
Hattersley
Company Name
Hattersley
Address
Crane House, Epsilon Terrace, West Road, Ipswich
Postcode
IP3 9FJ

View All Listings by this Company

Print This Approval


#1907383

Range of non-verifiable double check valve assemblies, consisting of two spring loaded resilient trim in-line check valve cartridges housed in DZR brass bodies (chromium plated) with a drain port located between the cartridges. Maximum working pressure 16.0 (15-28mm & 1¼” - 2” BSP F) or 25.0 bar (½” - 1” BSP F). Maximum operating temperature 60°C.

Section:
0034 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type ED - Non-verifiable double check valve.
WRAS Approval Number:
1907383
Expiry date:
31/07/2024
Marking:
HNH, FLOW ARROW, CR, SIZE & MADE IN ITALY ON BODY
Installation Requirements:
R001
Model:
FIG 250CW:15 mm compression, 22mm compression & 28mm compression. FIG 250W 1¼” BSP (F), 1½” BSP (F) & 2” BSP (F). FIG 250W: ½” BSP (F), ¾” BSP (F) & 1” BSP (F).
Factor:
Hattersley
Company Name
Hattersley
Address
Crane House, Epsilon Terrace, West Road, Ipswich
Postcode
IP3 9FJ

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 7

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.