Unvented Heating Apparatus

Section Code 1890 :

Back To Directory Sections

#2106034

Range of “POWERflow” Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 4.5 bar at 90˚C and an expansion relief valve set at 3.5 bar. The product is supplied with a pressure reducing valve set at 2.1 bar, expansion vessel, tundish and an approved check assembly (suitable for backflow protection against Fluid Category 2). Primary circuit max working pressure: 3.5 bar Secondary circuit max working pressure: 3.0 bar Solar Coil max working pressure: 3.5 bar Primary and Secondary circuit maximum operating temperature 75.0°C Solar Coil max operating temperature 80.0°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2106034
Expiry date:
30/06/2026
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
Primary Circuit: 22mm compression. Secondary circuit: 22mm compression. Solar circuit: 22mm compression. Drain connection: 15mm compression.
Marking:
McDonald Water Storage, POWERflow and other product info on labels on body.
Installation Requirements:
R001 R140 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°C and 45°C.
Model:
POWERflow Range of unvented hot water storage cylinders: 75, 120, 150, 165, 180, 210, 250, 300 Litres Indirect & Direct. Solar Coil option on 120L and above. PD1 - 75 Litre Direct POWERflow, PI1 - 75 Litre Indirect POWERflow Size = 950 x 450mm Connections = 6 (Direct) / 9 (Indirect) PD2 - 120 Litre Direct POWERflow, PI2 - 120 Litre Indirect POWERflow Size = 950 x 550mm Connections = 6 (Direct) / 9 (Indirect) PD3 - 150 Litre Direct POWERflow, PI3 - 150 Litre Indirect POWERflow Size = 1150 x 550mm Connections = 7 (Direct) / 9 (Indirect) PD5 - 165 Litre Direct POWERflow, PI5 - 165 Litre Indirect POWERflow Size = 1250 x 550mm Connections = 7 (Direct) / 9 (Indirect) PD6 - 180 Litre Direct POWERflow, PI6 - 180 Litre Indirect POWERflow Size = 1350 x 550mm Connections = 8 (Direct) / 10 (Indirect) PD4 - 210 Litre Direct POWERflow, PI4 - 210 Litre Indirect POWERflow Size = 1550 x 550mm Connections = 8 (Direct) / 10 (Indirect) PD7 - 250 Litre Direct POWERflow, PI7 - 250 Litre Indirect POWERflow Size = 1550 x 600mm Connections = 8 (Direct) / 10 (Indirect) PD8 - 300 Litre Direct POWERflow, PI8 - 300 Litre Indirect POWERflow Size = 1850 x 600mm Connections = 8 (Direct) / 10 (Indirect)
Manufacturer:
MCDONALD WATER STORAGE
Company Name
MCDONALD WATER STORAGE
Address
QUEENSWAY INDUSTRIAL ESTATE GLENROTHES FIFE
Postcode
KY7 5QF

View All Listings by this Company

Print This Approval


#2107032

Mitsubishi Electric ‘EHPT20Q – VM2EA’ stainless steel unvented primary thermal store cylinder unit. An inline booster heater is also fitted into the primary circuit. The cylinder is fitted with two pressure relief valves set at 3.0 bar. Heat is transferred from the stored primary water to the secondary water circuit via a plate heat exchanger which provides instantaneous hot water. The primary thermal storage cylinder is to be filled by the use of the supplied temporary filling loop assembly, which consistd of a stainless steel braided EPDM lined flexible hose, a lever operated brass spherical valve and a DZR brass double check valve assembly (suitable for backflow protection against Fluid Category 3) that incorporates a lever operated spherical valve. A primary expansion vessel is supplied to accommodate the expansion of the primary water when heated. An automatic air vent is fitted to the top of the thermal store. The product is supplied with a tundish. Maximum working pressure: Primary circuit 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature: Primary circuit 72°C, Secondary circuit 70°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2107032
Expiry date:
31/07/2026
Size:
Primary and Secondary circuit: 22mm connection. Outdoor heating unit: ½” BSP (M)
Marking:
Mitsubishi, model and technical information including capacity and pressure on adhesive label on top of unit.
Installation Requirements:
R001
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
EHPT20Q-VM2EA
Factor:
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Company Name
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Address
Nettlehill Road, Houston Industrial Estate, Livingston
Postcode
EH54 5EQ
Country
United Kingdom
Phone
01405 44 55 00

View All Listings by this Company

Print This Approval


#2103035

McDonald Steel Flow ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103035
Expiry date:
31/03/2026
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
McDonald Water Storage & Steel Flow on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
CS90D - MCDONALD STEELFLOW 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS120D - MCDONALD STEELFLOW 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS150D - MCDONALD STEELFLOW 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS170D - MCDONALD STEELFLOW 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS200D - MCDONALD STEELFLOW 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS250D - MCDONALD STEELFLOW 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS300D - MCDONALD STEELFLOW 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. CS90I - MCDONALD STEELFLOW 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS120I - MCDONALD STEELFLOW 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS150I - MCDONALD STEELFLOW 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. CS170I - MCDONALD STEELFLOW 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS200I - MCDONALD STEELFLOW 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS250I - MCDONALD STEELFLOW 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. CS300I - MCDONALD STEELFLOW 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS170DS - MCDONALD STEELFLOW 170 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER CS200DS - MCDONALD STEELFLOW 200 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER CS250DS - MCDONALD STEELFLOW 250 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER CS300DS - MCDONALD STEELFLOW 300 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER CS170IS - MCDONALD STEELFLOW 170 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER CS200IS - MCDONALD STEELFLOW 200 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER. CS325IS - MCDONALD STEELFLOW 250 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER CS300IS - 300 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER. CS60DSL - MCDONALD STEELFLOW SLIM 60 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS90DSL - MCDONALD STEELFLOW SLIM 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS120DSL - MCDONALD STEELFLOW SLIM 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS150DSL - MCDONALD STEELFLOW SLIM 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS170DSL - MCDONALD STEELFLOW SLIM 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS200DSL - MCDONALD STEELFLOW SLIM 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER CS60ISL - MCDONALD STEELFLOW SLIM 60 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS90ISL - MCDONALD STEELFLOW SLIM 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS120ISL - MCDONALD STEELFLOW SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS150ISL - MCDONALD STEELFLOW SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS170ISL - MCDONALD STEELFLOW SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER CS200ISL - MCDONALD STEELFLOW SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER
Factor:
MCDONALD WATER STORAGE
Company Name
MCDONALD WATER STORAGE
Address
QUEENSWAY INDUSTRIAL ESTATE GLENROTHES FIFE
Postcode
KY7 5QF

View All Listings by this Company

Print This Approval


#2103340

Stainless steel indirect thermal store. The primary circuit is factory fitted with a temperature and pressure relief valve (3 bar and 92°C). Hot water storage for space heating via air to water heat pump Maximum working pressure: Primary circuit 3.0 bar Maximum operating temperature 85°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103340
Expiry date:
31/03/2026
Size:
1 ¼” BSP(F) x 1 ¼” BSP(F)
Marking:
Polar Energi, model no, date of manufacture, capacity,& pressure on adhesive label on cover.
Installation Requirements:
R001 R140
Model:
PAW-VP380L INDIRECT THERMAL STORE
Factor:
Panasonic UK, a branch of Panasonic Marketing Europe GmbH
Company Name
Panasonic UK, a branch of Panasonic Marketing Europe GmbH
Address
Maxis 2 Western Road Bracknell Berkshire
Postcode
RG12 1RT

View All Listings by this Company
Manufacturer:
Polar Energi
Company Name
Polar Energi
Address
Polar Energi AS Bygdaveien 172 9450 Hamnvik
Country
Norway
Phone
+4777029222

View All Listings by this Company

Print This Approval


#2107329

SSB, SSI SST range of stainless steel unvented cylinders provided with an unvented kit supplied with cylinders containing a temperature and pressure reducing valve set at 3.0 bar and an expansion vessel and single check valve (suitable for fluid category 2) . Available as storage tank, indirect or twin coil. Maximum working pressure of the cylinder 6.0 bar, maximum working pressure of the coil or coils 12.0 bar. Maximum operating temperature 95°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2107329
Expiry date:
31/07/2026
Size:
See model
Marking:
Adveco on body. Adveco logo, model no, pressure, temp and other technical information on data label on body.
Installation Requirements:
R001 R140
Model:
Model Capacity (L) SSB200 191 SSB300 286 SSB500 481 SSB800 763 SSB1000 952 SSB1500 1426 SSB2000 2002 SSB2500 2535 No coils 1 x blanking plate in upper flange 1x blanking plate in lower flange SSI200/1.0 188 SSI300/1.0 283 SSI500/1.5 476 SSI800/1.5 758 SSI800/3.0 753 SSI1000/5.0 935 SSI1500/4.0 1413 SSI1500/6.0 1407 SSI 2000/4.0 1989 SSI 2000/6.0 1983 SSI 2500/4.0 2522 SSI 2500/6.0 2516 1 x blanking plate in upper flange 1 x coil in lower flange
SST200/1.0 184 SST300/1.0 279 SST500/1.5 470 SST800/1.5 752 SST800/3.0 743 SST1000/5.0 918 SST1500/4.0 1399 SST1500/6.0 1387 SST2000/4.0 1975 SST2000/6.0 1963 SST2500/4.0 2508 SST2500/6.0 2496 1 x coil in upper flange 1 x coil in lower flange
Manufacturer:
Adveco Ltd
Company Name
Adveco Ltd
Address
Unit 7 & 8 Armstrong Mall Southwood Business Park Farnborough Hants
Postcode
GU14 0NR
Country
United Kingdom
Phone
01252 551 540

View All Listings by this Company

Print This Approval


#2104330

Range of domestic stainless steel indirect unvented hot water storage cylinder incorporating a stainless steel coil for connection to a heat pump circuit. The secondary circuit is factory fitted with a temperature and pressure relief valve (10 bar and 92°C) and an Incoloy immersion heater and magnesium sacrificial anode. Maximum working pressure: Secondary circuit 9.5 bar. Maximum operating temperature 95°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2104330
Expiry date:
30/04/2026
Size:
1 ¼” BSP (F) x 1 ¼” BSP (F)
Marking:
Polar Energi, model number, date of manufacture (MM/YY), capacity & pressure on adhesive label on cover.
Installation Requirements:
R001 R140
Model:
VP200L DHW VP500L DHW VP750L DHW VP1000L DHW
Factor:
Polar Energi
Company Name
Polar Energi
Address
Polar Energi AS Bygdaveien 172 9450 Hamnvik
Country
Norway
Phone
+4777029222
General Email
post@polarenergi.com

View All Listings by this Company

Print This Approval


#2110326

Range of indirect and direct unvented storage cylinders consisting of either no coil (GLE) or a factory fitted single (GLC) or twin coil (GLT). The secondary circuit is supplied with a temperature and pressure relief valve set at 7.0 bar@85˚C for 1.0-6.0 bar products and 10.5 bar@95°C for 6.0-10.0 bar products. The products are supplied with an inlet control group (safety kit) consisting of a pressure reducing valve, an expansion relief valve 6.0 bar (1.0-6.0 bar products) or 10.5 bar (6.0-10.0 bar products) and an approved check valve, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Product is also supplied with an expansion vessel. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2110326
Expiry date:
31/10/2026
Size:
1 ½” BSP (M) secondary (inlet kit) 1 ½” BSF (F) secondary cylinder 1” BSP( F) primary coils
Marking:
Adveco badge on casing Serial No, Adveco, address, model no. capacity, & other tech info on adhesive label on body G3 warning label, maintenance label, service label, energy label on casing
Installation Requirements:
R001 R040
Model:
Adveco GLE Range GLE 200, GLE 300, GLE 500, GLE 750, GLE1000 Adveco GLC Range GLC 200, GLC 300, GLC 500, GLC 750, GLC 1000. Adveco GLT Range GLT 200, GLT 300, GLT 500, GLT 750, GLT1000
Factor:
Adveco Ltd
Company Name
Adveco Ltd
Address
Unit 7 & 8 Armstrong Mall Southwood Business Park Farnborough Hants
Postcode
GU14 0NR
Country
United Kingdom
Phone
01252 551 540
General Email
enquiries@adveco.co

View All Listings by this Company

Print This Approval


#2104346

Range of free standing direct gas fired unvented cyliners with a enamel coating internal lining and magnesium sacrificial anode. Fitted with a combined temperature and pressure relief valve set at 7 bar. Maximum working pressure 6.5 bar. Maximum operating temperature 80°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2104346
Expiry date:
30/04/2026
Size:
1” BSP(M) x 1”BSP(M)
Marking:
Elco, serial no, gas type, capacity and other techcnial on adhesive on label information on body.
Installation Requirements:
R001 R140
Model:
TUDOR NHREC 20 TUDOR NHREC 40 TUDOR NHREC 65 TUDOR NHREX 18 TUDOR NHREX 26 TUDOR NHREX 36 TUDOR NHREX 60 The AEALN / NHREX family of product has straight exhaust that goes from the burner through the tank up to the top of the water heater The COE family of product has a corkscrew exhaust that goes through the tank and exit at the base of the water heater Each water heater through specific setting can be used with 3 different type of gas: - G 20 = Methane - G 25 = Town Gas - G31 = Propane (LPG)
Factor:
Elco Heating Solutions Limited
Company Name
Elco Heating Solutions Limited
Address
Juniper West, 3 Fenton Way Southshields Business Park Basildon
Postcode
SS15 6SJ
Country
Essex
Phone
01268 546 700
General Email
enquiries@elco.co.uk

View All Listings by this Company

Print This Approval


#1911081

Infinty-E stainless steel direct unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911081
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2). The above sizes on the approval to be modified to the below: 22mm or 28mm compression connection (manifold) secondary inlet, 22mm or 28mm stub connection secondary outlet 22mm stub or ½”F BSP secondary return 22mm stub connections coil1 inlet and outlet 28mm or 32mm stub connections cold inlet and outlet
Marking:
Rinnai, part number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
INFINITY-E HOT WATER STORAGE CYLINDER
Factor:
Rinnai UK Ltd
Company Name
Rinnai UK Ltd
Address
9 Christleton Court Manor Park Runcom
Postcode
WA7 18T
Phone
01928 531 870
General Email
info@rinnaiuk.com

View All Listings by this Company

Print This Approval


#2104347

Range of domestic stainless steel indirect unvented hot water storage cylinder incorporating a stainless steel coil for connection to a heat pump circuit. The secondary circuit is factory fitted with a temperature and pressure relief valve (10 bar and 92°C) and an Incoloy immersion heater and magnesium sacrificial anode. Maximum working pressure: Secondary circuit 9.5 bar. Maximum operating temperature 95°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2104347
Expiry date:
30/04/2026
Size:
1 ¼” BSP (F) x 1 ¼” BSP (F)
Marking:
Polar Energi, model number, date of manufacture (MM/YY), capacity & pressure on adhesive label on cover.
Installation Requirements:
R001 R140
Model:
PAW-VP750L-DHW-1 & PAW-VP1000L-DHW-1 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER
Factor:
Panasonic UK, a branch of Panasonic Marketing Europe GmbH
Company Name
Panasonic UK, a branch of Panasonic Marketing Europe GmbH
Address
Maxis 2 Western Road Bracknell Berkshire
Postcode
RG12 1RT

View All Listings by this Company
Manufacturer:
Polar Energi
Company Name
Polar Energi
Address
Polar Energi AS Bygdaveien 172 9450 Hamnvik
Country
Norway
Phone
+4777029222

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 4 of 6

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.