Unvented Heating Apparatus

Section Code 1890 :

Back To Directory Sections

#1911074

Range of Advance Appliance stainless steel indirect and direct unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911074
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2). The above sizes on the approval to be modified to the below: 22mm or 28mm compression connection (manifold) secondary inlet, 22mm or 28mm stub connection secondary outlet 22mm stub or ½”F BSP secondary return 22mm stub connections coil1 inlet and outlet 28mm or 32mm stub connections cold inlet and outlet
Marking:
ADVANCE APPLIANCES, part number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
Advance Appliances- Heat Pump- single coil HP 135/ 150/215/ 255/ 305 HPL 255/ 305/ 400/ 500 Advance Appliances- Heat Pump - twin coil HPS 215/ 255/ 305 HPSL 305/ 400/ 500 Advance Appliances- Buffer Store - BFS 80/ 150/ 215/ 255/ 305/ 500
Factor:
Advance Appliances Ltd.
Company Name
Advance Appliances Ltd.
Address
Unit 4 Coppice Side Industrial Estate, Brownhills, Walsall
Postcode
WS8 7EX

View All Listings by this Company

Print This Approval


#2007084

Advance Appliance ranges of direct, indirect, solar direct and solar indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar 95°C, an inlet manifold consisting of an in-line pressure reducing valve adjustable between 2.7 & 3.3 bar (but factory set @ 3.0 bar), an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), a pre-set expansion relief valve set at 6.0 bar and a strainer. The product is supplied with a tundish. Maximum supply pressure to pressure reducing valve is 10.0 bar. Maximum working pressure Primary circuit 6.0 bar. Maximum working pressure Secondary circuit 5.5 bar. Maximum operating temperature 85˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2007084
Expiry date:
31/07/2025
Note:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°C.
Size:
See model
Marking:
Adhesive label on side of cylinder with Advance Appliances model, address and technical information including temperature, capacity and pressure.
Installation Requirements:
R001 R140 R360
Model:
Advances Appliances Indirect - single coil ipp 175 Advance Appliances Indirect- single coil ipp 250
Factor:
Advance Appliances Ltd.
Company Name
Advance Appliances Ltd.
Address
Unit 4 Coppice Side Industrial Estate, Brownhills, Walsall
Postcode
WS8 7EX

View All Listings by this Company

Print This Approval


#1911075

Range of Element stainless steel indirect and direct unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911075
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2). The above sizes on the approval to be modified to the below: 22mm or 28mm compression connection (manifold) secondary inlet, 22mm or 28mm stub connection secondary outlet 22mm stub or ½”F BSP secondary return 22mm stub connections coil1 inlet and outlet 28mm or 32mm stub connections cold inlet and outlet
Marking:
Element by Dutypoint on front of body Dutypoint, WRAS, part number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
Product Range: External expansion ranges: Element Direct:80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Element indirect: 80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Element Solar Direct: 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Element Solar Indirect: 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Element Heat Pump (single coil): 150L, 175L, 215L, 255L, 305L,400L, 500L Element Heat Pump (twin coil): 150L, 175L, 215L, 255L, 305L, 400L, 500L Element Direct slim line: 100L, 130L, 150L, 175L, 210L Element indirect slim line: 100L, 130L, 150L, 175L, 210L Element Direct super slim line: 80L, 100L, 130L, 150L, 165L Element indirect super slim line: 80L, 100L, 130L, 150L, 165L Element Renewables’, slim line: 100L. 130L, 150L, 175L, 210L Element Buffer: 80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L
Factor:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Olympus Park, Quedgeley Gloucestershire
Postcode
GL2 4DH
General Email
sales@dutypoint.com

View All Listings by this Company

Print This Approval


#2103025

Range of “Tempest” Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 3.0 bar & Solar circuit 5.5 bar. Maximum operating temperature 65°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103025
Expiry date:
31/03/2026
Size:
Primary circuit: 1” BSP (F) Secondary circuit: 1” BSP (F) Solar circuit: 1” BSP (F)
Marking:
Telford solar on label. Telford stainless and technical information including capacity and pressures on adhesive label on body.
Installation Requirements:
R001 R140 R360 R530
Model:
TSMIXXX - Tempest indirect XXXL single coil unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L, 125 = 125L, 150 = 150L, 170 = 170L, 200 = 200L, 250 = 250L, 300 = 300L, 400 = 400L, 500 = 500L. TSMIXXX/S - Tempest indirect XXXL twin coil boiler & solar unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 170 = 170L, 200 = 200L, 250 = 250L, 300 = 300L, 400 = 400L, 500 = 500L. TSMDXXX - Tempest direct XXXL electric only unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L, 125 = 125L, 150 = 150L, 170 = 170L, 200 = 200L, 250 = 250L, 300 = 300L.
Manufacturer:
Telford Copper & Stainless Cylinders Ltd
Company Name
Telford Copper & Stainless Cylinders Ltd
Address
Unit 22 Furrows Business Park Haybridge Road
Postcode
TF1 2DF
Country
Wellington

View All Listings by this Company

Print This Approval


#2103009

Whitewolf Alpha ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103009
Expiry date:
31/03/2026
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
Whitewolf Cylinders on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
WWA90D - Whitewolf Alpha 90 Direct WWA120D - Whitewolf Alpha 120 Direct WWA150D - Whitewolf Alpha 150 Direct WWA170D - Whitewolf Alpha 170 Direct WWA200D - Whitewolf Alpha 200 Direct WWA250D - Whitewolf Alpha 250 Direct WWA300D - Whitewolf Alpha 300 Direct WWA90I - Whitewolf Alpha 90 Indirect WWA120I - Whitewolf Alpha 120 Indirect WWA150I - Whitewolf Alpha 150 Indirect WWA170I - Whitewolf Alpha 170 Indirect WWA200I - Whitewolf Alpha 200 Indirect WWA250I - Whitewolf Alpha 250 Indirect WWA300I - Whitewolf Alpha 300 Indirect WWA170S - Whitewolf Alpha 170 Indirect Solar Single Coil WWA200S - Whitewolf Alpha 200 Indirect Solar Single Coil WWA250S - Whitewolf Alpha 250 Indirect Solar Single Coil WWA300S - Whitewolf Alpha 300 Indirect Solar Single Coil WWA170T - Whitewolf Alpha 170 Indirect Solar Twin Coil WWA200T - Whitewolf Alpha 200 Indirect Solar Twin Coil WWA250T - Whitewolf Alpha 250 Indirect Solar Twin Coil WWA300T - Whitewolf Alpha 300 Indirect Solar Twin Coil WWAS60D - Whitewolf Alpha Slim 60 Direct WWAS90D - Whitewolf Alpha Slim 90 Direct WWAS120D - Whitewolf Alpha Slim 120 Direct WWAS150D - Whitewolf Alpha Slim 150 Direct WWAS170D - Whitewolf Alpha Slim 170 Direct WWAS200D - Whitewolf Alpha Slim 200 Direct WWAS60I - Whitewolf Alpha Slim 60 Indirect WWAS90I - Whitewolf Alpha Slim 90 Indirect WWAS120I - Whitewolf Alpha Slim 120 Indirect WWAS150I - Whitewolf Alpha Slim 150 Indirect WWAS170I - Whitewolf Alpha Slim 170 Indirect WWAS200I - Whitewolf Alpha Slim 200 Indirect
Factor:
Whitewolf Cylinders Ltd
Company Name
Whitewolf Cylinders Ltd
Address
Unit 2, 30 Junction Business Park 119/121 Ouzlewell Green Lofthouse, West Yorkshire
Postcode
WF3 3QW
Country
United Kingdom
Phone
01132 822710
General Email
mail@whitewolfcylinders.com

View All Listings by this Company

Print This Approval


#2103028

Elite ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103028
Expiry date:
31/03/2026
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
UK CYLINDERS ELITE on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
ESDIR0090 – UK CYLINDERS ELITE 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESDIR0120 – UK CYLINDERS ELITE 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESDIR0150 – UK CYLINDERS ELITE 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESDIR0170 – UK CYLINDERS ELITE 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESDIR0200 – UK CYLINDERS ELITE 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESDIR0250 – UK CYLINDERS ELITE 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESDIR0300 – UK CYLINDERS ELITE 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. ESIND0090-UK CYLINDERS ELITE 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESIND0120-UK CYLINDERS ELITE 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESIND0150-UK CYLINDERS ELITE 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. ESIND0170-UK CYLINDERS ELITE 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESIND0200-UK CYLINDERS ELITE 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESIND0250-UK CYLINDERS ELITE 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. ESIND0300-UK CYLINDERS ELITE 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESSDI0170-UK CYLINDERS ELITE 170 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER ESSDI0200-UK CYLINDERS ELITE 200 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER ESSDI0250-UK CYLINDERS ELITE 250 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER ESSDI0300-UK CYLINDERS ELITE 300 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER ESSIN0170-UK CYLINDERS ELITE 170 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER ESSIN0200-UK CYLINDERS ELITE 200 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER. ESSIN0250-UK CYLINDERS ELITE 250 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER ESSIN0300-UK CYLINDERS ELITE 300 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER. ESNDI0060-UK CYLINDERS ELITE SLIM 60 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNDI0090-UK CYLINDERS ELITE SLIM 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNDI0120-UK CYLINDERS ELITE SLIM 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNDI0150-UK CYLINDERS ELITE SLIM 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNDI0170-UK CYLINDERS ELITE SLIM 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNDI0200-UK CYLINDERS ELITE SLIM 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNIN0060-UK CYLINDERS ELITE SLIM 60 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNIN0090-UK CYLINDERS ELITE SLIM 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNIN0120-UK CYLINDERS ELITE SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNIN0150-UK CYLINDERS ELITE SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNIN0170-UK CYLINDERS ELITE SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER ESNIN0200-UK CYLINDERS ELITE SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER
Factor:
UK CYLINDERS LTD
Company Name
UK CYLINDERS LTD
Address
UNIT 3 RCM BUSINESS CENTRE WEST YORKSHIRE
Postcode
WF5 9ND

View All Listings by this Company

Print This Approval


#2103029

Flowcyl ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103029
Expiry date:
31/03/2026
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
UK CYLINDERS FLOWCYL on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
FCDIR0090-UK CYLINDERS FLOWCYL 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCDIR0120 – UK CYLINDERS FLOWCYL 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCDIR0150 – UK CYLINDERS FLOWCYL 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCDIR0170 – UK CYLINDERS FLOWCYL 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCDIR0200 – UK CYLINDERS FLOWCYL 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCDIR0250 – UK CYLINDERS FLOWCYL 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCDIR0300 – UK CYLINDERS FLOWCYL 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. FCIND0090-UK CYLINDERS FLOWCYL 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCIND0120-UK CYLINDERS FLOWCYL 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCIND0150-UK CYLINDERS FLOWCYL 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. FCIND0170-UK CYLINDERS FLOWCYL 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCIND0200-UK CYLINDERS FLOWCYL 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCIND0250-UK CYLINDERS FLOWCYL 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. FCIND0300-UK CYLINDERS FLOWCYL 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCSDI0170-UK CYLINDERS FLOWCYL 170 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER FCSDI0200-UK CYLINDERS FLOWCYL 200 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER FCSDI0250-UK CYLINDERS FLOWCYL 250 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER FCSDI0300-UK CYLINDERS FLOWCYL 300 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER FCSIN0170-UK CYLINDERS FLOWCYL 170 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER FCSIN0200-UK CYLINDERS FLOWCYL 200 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER. FCSIN0250-UK CYLINDERS FLOWCYL 250 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER FCSIN0300-UK CYLINDERS FLOWCYL 300 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER. FCNDI0060-UK CYLINDERS FLOWCYL SLIM 60 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNDI0090-UK CYLINDERS FLOWCYL SLIM 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNDI0120-UK CYLINDERS FLOWCYL SLIM 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNDI0150-UK CYLINDERS FLOWCYL SLIM 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNDI0170-UK CYLINDERS FLOWCYL SLIM 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNDI0200-UK CYLINDERS FLOWCYL SLIM 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNIN0060-UK CYLINDERS FLOWCYL SLIM 60 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNIN0090-UK CYLINDERS FLOWCYL SLIM 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNIN0120-UK CYLINDERS FLOWCYL SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNIN0150-UK CYLINDERS FLOWCYL SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNIN0170-UK CYLINDERS FLOWCYL SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER FCNIN0200-UK CYLINDERS FLOWCYL SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER
Factor:
UK CYLINDERS LTD
Company Name
UK CYLINDERS LTD
Address
UNIT 3 RCM BUSINESS CENTRE WEST YORKSHIRE
Postcode
WF5 9ND

View All Listings by this Company

Print This Approval


#2103031

Nucyl ranges of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103031
Expiry date:
31/03/2026
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
UK CYLINDERS NUCYL on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
WWA90D -WHITEWOLF ALPHA 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER NUDIR0090-UK CYLINDERS NUCYL 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA120D -WHITEWOLF ALPHA 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER NUDIR0120 – UK CYLINDERS NUCYL 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA150D -WHITEWOLF ALPHA 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER NUDIR0150 – UK CYLINDERS NUCYL 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA170D -WHITEWOLF ALPHA 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER NUDIR0170 – UK CYLINDERS NUCYL 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA200D -WHITEWOLF ALPHA 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER NUDIR0200 – UK CYLINDERS NUCYL 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA250D -WHITEWOLF ALPHA 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER FNUIR0250 – UK CYLINDERS NUCYL 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA300D -WHITEWOLF ALPHA 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. NUDIR0300 – UK CYLINDERS NUCYL 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. WWA90I -WHITEWOLF ALPHA 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER NUIND0090-UK CYLINDERS NUCYL 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA120I -WHITEWOLF ALPHA 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER NUIND0120-UK CYLINDERS NUCYL 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA150I-WHITEWOLF ALPHA 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. NUIND0150-UK CYLINDERS NUCYL 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. WWA170I-WHITEWOLF ALPHA 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER NUIND0170-UK CYLINDERS NUCYL 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA200IWHITEWOLF ALPHA 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER NUIND0200-UK CYLINDERS NUCYL 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER WWA250I-WHITEWOLF ALPHA 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. NUIND0250-UK CYLINDERS NUCYL 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. WWA300I-WHITEWOLF ALPHA 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER NUIND0300-UK CYLINDERS NUCYL 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER
Factor:
UK CYLINDERS LTD
Company Name
UK CYLINDERS LTD
Address
UNIT 3 RCM BUSINESS CENTRE WEST YORKSHIRE
Postcode
WF5 9ND

View All Listings by this Company

Print This Approval


#2104314

Range of free standing direct gas fired unvented cyliners with a enamel coating internal lining and magnesium sacrificial anode. Fitted with a combined temperature and pressure relief valve set at 7 bar. Maximum working pressure 6.5 bar. Maximum operating temperature 80°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2104314
Expiry date:
30/04/2026
Size:
1” BSP(M) x 1”BSP(M)
Marking:
Therm’inova, serial no, gas type, capacity and other techcnial information on body.
Installation Requirements:
R001 R140
Model:
COE / NHREC 18 kW (G20/G25/G31) COE / NHREC 36 kW (G20/G25/G31) COE / NHREC 60 kW (G20/G25/G31) AEALN / NHREX 18 kW (G20/G25/G31) AEALN / NHREX 26 kW (G20/G25/G31) AEALN / NHREX 36 kW (G20/G25/G31) AEALN / NHREX 60 kW (G20/G25/G31) The AEALN / NHREX family of product has straight exhaust that goes from the burner through the tank up to the top of the water heater The COE family of product has a corkscrew exhaust that goes through the tank and exit at the base of the water heater Each water heater through specific setting can be used with 3 different type of gas: - G 20 = Methane - G 25 = Town Gas - G31 = Propane (LPG)
Manufacturer:
Therm'inova
Company Name
Therm'inova
Address
1 Rue Des Bornes 27140 Gisors
Country
France
Phone
+33 (0)2 32 27 85 08

View All Listings by this Company

Print This Approval


#2103330

Stainless steel indirect thermal store. The primary circuit is factory fitted with a temperature and pressure relief valve (3 bar and 92°C). Hot water storage for space heating via air to water heat pump? Maximum working pressure: Primary circuit 3.0 bar Maximum operating temperature 85°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103330
Expiry date:
31/03/2026
Size:
1 ¼” BSP(F) x 1 ¼” BSP(F)
Marking:
Polar Energi, model no, date of manufacture, capacity,& pressure on adhesive label on cover.
Installation Requirements:
R001 R140
Model:
VP380L
Factor:
Polar Energi
Company Name
Polar Energi
Address
Polar Energi AS Bygdaveien 172 9450 Hamnvik
Country
Norway
Phone
+4777029222
General Email
post@polarenergi.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 3 of 6

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.