Combination Tap Assemblies

Section Code 0684 : Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.

Back To Directory Sections

#1907319

Range of single hole, single outlet, fixed electronically controlled tap assemblies (chromium plated brass), incorporating a solenoid valve controlling the flow which is actuated via infrared sensor. The spouts incorporate adjustable combined plastic and rubber aerators and the inlets incorporate plastic strainers. Temperature can be set via an access point on the side of the valve. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
1907319
Expiry date:
31/07/2024
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating ⅜” end connections.
Marking:
HEWI logo on body.
Installation Requirements:
R001 R006 R009 R010 R570
Model:
HEWI SENSROIC Range: HEWI AQ 800 – AQ1.12S20040 (240v supply) HEWI AQ 800 – AQ1.12S20140 (battery) HEWI AQ 950 – AQ1.12S21040 (240v supply) HEWI AQ 950 – AQ1.12S21140 (battery) Model codes have changed from June 2021: AQ1.12S200yy AQ1.12S20060-Fc. AQ1.12S201yy AQ1.12S20160-Fc. AQ1.12S210yy AQ1.12S21060-Fc. AQ1.12S211yy AQ1.12S21160-Fc. yy denotes surface finish of faucet 40 = chrome 60 = powder coating (colour options defined under -Fc.) XA = stainless steel finish -Fc. Denotes optional powder-coated surface finishes in combination with different lever options e.g. DC = matt black coloured.
Manufacturer:
Hewi Heinrich Wilke GmbH
Company Name
Hewi Heinrich Wilke GmbH
Address
Prof.-Bier-Straße 1-5 34454 Bad Arolsen
Country
Germany

View All Listings by this Company

Print This Approval


#1907320

Range of single hole, single outlet, fixed electronically controlled tap assemblies (chromium plated brass), incorporating a solenoid valve controlling the flow which is actuated via infrared sensor. The spouts incorporate plastic aerators and the inlets incorporate plastic strainers. Temperature can be set via an access point on the side of the valve. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
1907320
Expiry date:
31/07/2024
Size:
Stainless steel braided PEX lined flexible hose assemblies incorporating ⅜” end connections.
Marking:
HEWI logo on body.
Installation Requirements:
R001 R006 R009 R010 R570
Model:
HEWI SENSROIC Range: HEWI AQ 477/801 – AQ1.12S22040 (240v supply) HEWI AQ 477/801 – AQ1.12S22140 (battery) HEWI AQ 162 – AQ1.12S23040 (240v supply) HEWI AQ 162 – AQ1.12S23140 (battery) Product will change to the following codes June 2021: AQ1.12S220yy AQ1.12S22060-Fc AQ1.12S221yy AQ1.12S22160-Fc AQ1.12S230yy AQ1.12S23060-Fc AQ1.12S231yy AQ1.12S23160-Fc yy defines surface finish and can be replaced with: 40 - Chrome 60 - Powder coating (colour options defined under - Fc) XA - Stainless steel finish Fc denotes optional powder coated surface finishes in combination with different lever options, e.g. DC - matt black coloured.
Manufacturer:
Hewi Heinrich Wilke GmbH
Company Name
Hewi Heinrich Wilke GmbH
Address
Prof.-Bier-Straße 1-5 34454 Bad Arolsen
Country
Germany

View All Listings by this Company

Print This Approval


#1910020

Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated stainless steel body). Flow is controlled by a solenoid valve that is activated via an infrared sensor. The spout outlets incorporate plastic aerators. Models with two inlets are supplied with hoses that incorporate stainless steel strainers and an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models with single inlets incorporate stainless steel strainers. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
1910020
Expiry date:
31/10/2024
Note:
R010 only applies to models Extreme 1000LFB, Extreme 1000LFE, Extreme 1000LFB AISI316 & Extreme 1000LFE AISI316 models.
Size:
Models with one inlet: 10mm spigot connection. Models with two inlets: stainless steel braided PE-X lined flexible hose assemblies incorporating ⅜” BSP captive nut.
Marking:
Stern logo on top of tap body
Installation Requirements:
R001 R006 R009 R010
Model:
Models with one inlet: Extreme LFB, Extreme LFE, Extreme LFB AISI316 & Extreme LFE AISI316. Models with two inlets: Extreme 1000LFB, Extreme 1000LFE, Extreme 1000LFB AISI316 & Extreme 1000LFE AISI316.
Factor:
Y Stern Engineering (1989) Ltd
Company Name
Y Stern Engineering (1989) Ltd
Address
15 Gan Rave Blud 8122217 Yavne Israel

View All Listings by this Company

Print This Approval


#2003049

Range of deck mounted, single hole, single outlet (fixed) electronically controlled combination tap assembly (chromium plated brass). The flow is controlled via solenoid valve which is actuated by an infra-red sensor and the temperature is controlled independently via a single lever operating member (388MCHLH15, 398MCHLH15, 488MCHLH15 & 498MCHLH15). The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2003049
Expiry date:
31/03/2025
Note:
R010 only applies to models 388MCHLH15, 398MCHLH15, 488MCHLH15 & 498MCHLH15
Size:
15mm compression adapter.
Marking:
DELABIE on end of spout and flow straightener housing.
Installation Requirements:
R001 R006 R009 R010
Model:
38801515, 39801515, 48801515, 49801515, 388MCHLH15, 398MCHLH15, 488MCHLH15, 498MCHLH15.
Factor:
Delabie Ltd.
Company Name
Delabie Ltd.
Address
1-3 Henderson House Hithercroft Road Wallingford
Postcode
OX10 9DG
Country
Oxfordshire
Phone
+44 1491 824 449

View All Listings by this Company
Manufacturer:
Delabie SAS
Company Name
Delabie SAS
Address
18 Rue Du Marechal Foch 80130 Friville Escarbotin France

View All Listings by this Company

Print This Approval


#1911337

Range of deck mounted single hole, single outlet (fixed) single feed electronically controlled tap assemblies (chromium plated brass). Flow is controlled via a solenoid valve (housed within a control unit) activated via an infra-red sensor. The inlet to the control unit incorporates a plastic flow regulator. The spout outlet incorporates a plastic or metal aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
1911337
Expiry date:
30/11/2024
Size:
⅜” BSP (M) (to control unit)
Marking:
TOTO on spout and cover of control unit
Installation Requirements:
R001 R006 R007
Model:
DLE124DHE4 (control unit) To be used in conjunction with the following tap spouts: TENA40AWV105 (114mm height spout), DLE110ANE4 (169mm height spout), DLE110A2NE4 (332mm height spout).
Manufacturer:
TOTO Europe GmbH
Company Name
TOTO Europe GmbH
Address
Zollhof 2 40211 Düsseldorf Germany
Phone
+49 211 273080

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 3 of 35

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.