Combination Tap Assemblies

Section Code 0550 : Two hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.

Back To Directory Sections

#1909068

Range of wall mounted, two hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a single sequential cartridge headwork and single lever operating members. The spout outlet incorporates a plastic flow straightener and the inlets also incorporates metal flow restrictors and a shut off valve. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.

Section:
0550 Combination Tap Assemblies
Section Subtitle:
Two hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1909068
Expiry date:
30/09/2024
Size:
½” BSP (M)
Marking:
Delabie on operating member.
Installation Requirements:
R001 R010 R040
Model:
Securitouch Range: 2436p & 2436.
Manufacturer:
Delabie SAS
Company Name
Delabie SAS
Address
18 Rue Du Marechal Foch 80130 Friville Escarbotin France

View All Listings by this Company

Print This Approval


#1909073

Range of deck mounted two-hole single outlet swivel combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 Bar. Maximum working temperature 60°C.

Section:
0550 Combination Tap Assemblies
Section Subtitle:
Two hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1909073
Expiry date:
30/09/2024
Size:
Stainless steel braided PE-X lined flexible hose assemblies incorporating 10mm spigot end connections.
Marking:
Dornbracht on tap body
Installation Requirements:
R001 R006 R007 R009 R010
Model:
32800680 32805680 32812680 32843680
Factor:
Aloys F Dornbracht GmbH & Co KG
Company Name
Aloys F Dornbracht GmbH & Co KG
Address
Koebbingser Muehle 6 D-58640 Iserlohn Germany
Phone
+49 2371 433 0

View All Listings by this Company

Print This Approval


#1910705

Range of two hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating either a ¼ turn ceramic disc (model 348119) or a non-rising spindle (models C48105 & C48113) headworks with either cross top (model C48113), dome type (modelC48105) or single lever (model C48119) operating members. The products are supplied with both an aerator and flow straightener and metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 65°C

Section:
0550 Combination Tap Assemblies
Section Subtitle:
Two hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1910705
Expiry date:
31/10/2024
Size:
½” BSP (M)
Marking:
SWAN LOGO BRAND OF WOLSELEY ON INDICE
Installation Requirements:
R001 R006 R010
Model:
C48113 SWAN X TOP 2 HOLE SINK MIXER, C48105 SWAN STANDARD 2 HOLE DECK SINK MIXER & C48119 SWAN 1/4 TURN LEVER DECK SINK MIXER
Factor:
Wolseley
Company Name
Wolseley
Address
Kingmaker Court Warwick Technology Park Warwick
Postcode
CV34 6DY

View All Listings by this Company

Print This Approval


#1910021

Range of two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members (BTDECKQT model) or non-rising spindle headwork with dome type operating members (BMDECK6L model). The spout outlets incorporate a plastic flow straightener (BMDECK6L model) or a plastic aerator (BTDECKQT model). The products are supplied with plastic backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C

Section:
0550 Combination Tap Assemblies
Section Subtitle:
Two hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1910021
Expiry date:
31/10/2024
Size:
½” BSP (M)
Marking:
Blanco on body
Installation Requirements:
R001 R006 R010
Model:
BTDECKQT & BMDECK6L.
Factor:
Blanco Limited
Company Name
Blanco Limited
Address
1 Victor Way, Colney Street, St Albans
Postcode
AL2 2FL

View All Listings by this Company

Print This Approval


#1912311

Range of two hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C

Section:
0550 Combination Tap Assemblies
Section Subtitle:
Two hole, metal, single outlet, swivel. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
1912311
Expiry date:
31/12/2024
Size:
½” BSP (M)
Marking:
DTC34 (brand name of Methven) on rear of body.
Installation Requirements:
R001 R006 R010
Model:
DLT105, VW DLT105, DLT SPEC105, 208.0574.213, 320890, DLV105, NLT105, 60177101.
Factor:
Methven UK Limited
Company Name
Methven UK Limited
Address
3-3A Stone Cross Court, Yew Tree Way, Golborne, Warrington
Postcode
WA3 3JE
Country
United Kingdom
Phone
0800 195 1602

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 3 of 14

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.