Range of floor mounted, single hole, single outlet (fixed), combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a manual diverter to shower outlet. The spout has a waterfall outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Spring loaded resilient trim, in-line check valve cartridge with plastic guides and stem and EPDM seals within a plastic housing. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 16.0 bar & maximum operating temperature 65°C.
Range of check valve cartridges with plastic bodies to be housed in specifically dimensioned bodies. The product incorporates a plastic flow regulator. Maximum working pressure 16.0 bar & maximum operating temperature 65°C.
Non-verifiable single check valve assembly consisting of a spring loaded, resilient trim, single check valve cartridge with a brushed chrome DZR brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
Range of in-line, non-verifiable single check valve assemblies with DZR brass bodies and spring loaded, resilient trim check valve cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC
Page 97 of 557
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.