‘AH Codes: 662016CB & 662014CB, CB Codes: 571983 & 571984’. White coloured, PTFE tape manufactured by calendering. For use with water up to 85°C.
'SPIT EPCON C8+ XTREM'. Site applied, brick coloured (once mixed), chemical anchor resin supplied in a pre-weighed dual cartridge. Apply as per manufacturer's instructions dated 'NOV. 25'. Cure for 24 hours@21°C. For use with water up to 23°C. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'MBMS0715'. Black coloured, compression moulded EPDM 'O' rings. Shore hardness 70. Tested in-radius size between 0.35mm and 5.0mm. For use with water up to 85°C.
'XX-01'. Black coloured, compression moulded EPDM rubber material. Shore hardness 50. Tested in-radius size 1.05mm. For use with water up to 85°C.
'NK8650W-EPDM'. Black coloured, compression moulded EPDM material. Shore hardness 65. Tested in-radius size 1.1mm. For use with water up to 65°C.
'JSP/SF-02'. Black coloured, compression moulded EPDM rubber material. Shore hardness 50. Tested in-radius size 1.05mm. For use with water up to 85°C.
'EW-001'. Black coloured, compression moulded EPDM material. Shore hardness 65. Tested in-radius size 1.0mm. For use with water up to 23°C.
'Griffon WDF-05®'. Site applied, blue coloured solvent cement. Apply as per manufacturer's instructions '6306959 20251027'. Cure for 30 minutes@12°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Concealed WC dual flushing cistern with a side entry BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure – 10.0 bar, cold water use only.
| Product Identification | Surface Finish / Colour | Dimension | Max Working Pressure (bar) | Max Operating Temp (°C) | Marking | Marking location | All metals in the water pathway are on the 4msi positive list | Headwork for Flow Control | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|
| AQRNDCV2 | Chrome | 5 | 80 | AQUALISA | shower valve | No | Ceramic cartridge | Not Applicable | Shower Hose, Handset, Fixed Head |
AQRNDCV2 Packed Products. Waterway contents are: SDCV.002 (Valve) 704418 (handset) ACY1008(hose) ACY1013(wall outlet) ACY1002(fixed arm) 704426(top shower)
Page 956 of 1045
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.