Directory Search Results

Print List

#2210301

Dual flush WC outlet valve incorporating an ABS body, operated via a push button assembly or a battery powered infra red sensor for either full or reduced flush. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not be verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2210301
Size:
2” BSP (M).
Marking:
NAT® on body.
Installation Requirements:
R001 R581
Expiry date:
31/10/2027
Model:
NB109-2 Touchless Sensor Flush Valve 3L/6L.

Approval Holder:
Xiamen Nat Plumbing Inc.
Company Name
Xiamen Nat Plumbing Inc.
Address
No.1, West Houxiang Road, Haicang District, Xiamen
Country
China
Phone
86-592-6538317

View All Listings by this Company
Manufacturer:
Xiamen Nat Plumbing Inc.
Company Name
Xiamen Nat Plumbing Inc.
Address
No.1, West Houxiang Road, Haicang District, Xiamen
Country
China
Phone
86-592-6538317

View All Listings by this Company

Print This Approval


#2211305

Range of automatic urinal flush valves with a plastic body. STD - Maximum working pressure 6.0 bar. LP - Maximum working pressure 0.5 bar. Cold water use only

Section:
1307 Flushing Mechanisms
Section Subtitle:
Urinals.
WRAS Approval Number:
2211305
Size:
½” BSP (F)
Marking:
Cistermiser and product info on adhesive label. Cistermiser and flow on body.
Installation Requirements:
R001 R075
Expiry date:
30/11/2027
Model:
STD LP
Product Images

Approval Holder:
Cistermiser Ltd
Company Name
Cistermiser Ltd
Address
Unit 1 Woodley Park Estate, 59/69 Reading Road Woodley
Postcode
RG5 3AN
Country
United Kingdom
General Email
jake.felstead@cistermiser.co.uk

View All Listings by this Company
Manufacturer:
Cistermiser Ltd
Company Name
Cistermiser Ltd
Address
Unit 1 Woodley Park Estate, 59/69 Reading Road Woodley
Postcode
RG5 3AN
Country
United Kingdom
General Email
jake.felstead@cistermiser.co.uk

View All Listings by this Company

Print This Approval


#2210032

Range of plate heat exchangers with stainless steel plates, for primary and secondary circulation. Models E040-2M-GB6 and R040-H2M-G6B are secondary use only. Maximum working pressure - R040-HNM-G6B range = 30.0 Bar and E040-NM-GB6 range = 20.0 Bar Maximum operating temperature - 99 °C

Section:
1350 Heat Exchangers
Size:
3/4" BSP Male
Marking:
Kaori Logo, Model, Max Pressure & Max Temp on Adhesive Label on Body. Model on Top Plate.
Installation Requirements:
R001
Expiry date:
31/10/2027
Model:
R040-HNM-G6B - “N” = Number of plates 2-40 plates E040-NM-GB6 - “N” = Number of plates 2-60 plates

Approval Holder:
Kaori Heat Treatment Co., Ltd
Company Name
Kaori Heat Treatment Co., Ltd
Address
No 5-2 Chi Lin North Road Chung Li District 320030

View All Listings by this Company
Manufacturer:
Kaori Heat Treatment Co., Ltd
Company Name
Kaori Heat Treatment Co., Ltd
Address
No 5-2 Chi Lin North Road Chung Li District 320030

View All Listings by this Company

Print This Approval


#2210054

Alfa Laval range of copper brazed and stainless-steel fusion bonded, stainless steel heat exchangers in various sizes ranging from 4 plates to 300 plates. Maximum working pressures and temperatures: CB10, CB11, CB15, CB16, CB16AQ, CB18, CB18AQ & CB18DW: S1/S2 circuit: 5 Bar. S3/S4 circuit 10 Bar. Max working temperature 150°C. CB20 & CB20AQ: S1/S2 circuit: 16 Bar. S3/S4 circuit 16 Bar. Max working temperature 225°C. CB65, CB65AQ & CBH65: S1/S2 circuit: 18 Bar. S3/S4 circuit 37 Bar. Max working temperature 225°C. CBH16 & CBH18: S1/S2 circuit: 32 Bar. S3/S4 circuit 32 Bar. Max working temperature 150°C. Maximum operating temperatures detailed above are for primary circuits only, secondary circuits approved to 99oC. Models added March 2023: CBH30: 50 Bar (S1/S2/S3/S4) & 225.0°C, CBH112: 45 Bar (S1/S2) 51 Bar (S3/S4) & 225.0°C, CB30: 41 Bar (S1/S2/S3/S4) & 225.0°C, CB60: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB60AQ: 40 Bar (S1/S2/S3/S4) & 225.0°C, CBH60: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB62: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB62AQ: 40 Bar (S1/S2/S3/S4) & 225.0°C, CBH62: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB30AQ: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB110: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB110AQ: 37 Bar (S1/S2/S3/S4) & 225.0°C, CBH110: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB112: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB112AQ: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB24: 29 Bar (S1/S2) 37 Bar (S3/S4) & 225.0°C, CB24AQ: 29 Bar (S1/S2) 37 Bar (S3/S4) & 225.0°C, ANTW66: 29.0 Bar (S1/S2/S3/S4), ANTW18: 23 Bar (S1/S2) 28 Bar (S3/S4) 225.0°C and RM11: 15 Bar (S3/S4) & 225.0°C. Maximum operating temperatures detailed above are for primary circuits only, secondary circuits approved to 99oC.

Section:
1350 Heat Exchangers
Size:
See Models
Marking:
CB10, CB15, CB16, CB18 models: Manufacturers logo, model number and technical information on label on from of heat exchanger. CB20 and CB65 models: Manufacturers logo, model number, serial number, manufacturing date (yyyy.mm.dd), minimum and maximum working temperature, minimum and maximum working pressure and technical information on label on front of heat exchanger. Models added March 2023: Alfa Laval logo, Model, serial number on adhesive label.
Installation Requirements:
R001
Expiry date:
31/10/2027
Model:
CB10: Minimum number of plates 4, Maximum number of plates 60. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB11: Minimum number of plates 8, Maximum number of plates 60. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB15: Minimum number of plates 4, Maximum number of plates 60. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB16/CBH16: Minimum number of plates 4, Maximum number of plates 60. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB16AQ: Minimum number of plates 4, Maximum number of plates 60. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections. CB18/CBH18: Minimum number of plates 4, Maximum number of plates 52. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB18AQ: Minimum number of plates 4, Maximum number of plates 60. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections. CB18DW: Minimum number of plates 4, Maximum number of plates 52. Connection Size/types: None O-ring, ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB20: Minimum number of plates 10, Maximum number of plates 110. Connection types: External thread or soldered. Connection Size/types: ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB20AQ: Minimum number of plates 10, Maximum number of plates 110. Connection Size/types: ¾” or 1” Male BSP connections. CB65/CBH65: Minimum number of plates 10, Maximum number of plates 150. Connection types: External thread or soldered. Connection Size/types: ¾” or 1” Male BSP connections or 12mm or 28mm soldered connections for use with copper tube conforming to EN 1057. CB65AQ: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” or 1” Male BSP connections Models added March 2023: CB30: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CB30AQ: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CBH30: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CB60: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CB60AQ: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CBH60: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CB62: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CB62AQ: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CBH62: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M. CB110: Minimum number of plates 10, Maximum number of plates 300. Connection Size/types: ¾” - 2” BSP M. CB110AQ: Minimum number of plates 10, Maximum number of plates 300. Connection Size/types: ¾” - 2” BSP M. CBH110: Minimum number of plates 10, Maximum number of plates 300. Connection Size/types: ¾” - 2” BSP M. CB112: Minimum number of plates 10, Maximum number of plates 300. Connection Size/types: ¾” - 2” BSP M. CB112AQ: Minimum number of plates 10, Maximum number of plates 300. Connection Size/types: ¾” - 2” BSP M. CBH112: Minimum number of plates 10, Maximum number of plates 300. Connection Size/types: ¾” - 2” BSP M. RM11: Minimum number of plates 28, Maximum number of plates 28. Connection Size/types: 22mm ID - soldered connection for use with copper tube conforming to EN 1057. CB24: Minimum number of plates 10, Maximum number of plates 56. Connection Size/types: ¾” - 2” BSP M. ANTW18: Minimum number of plates 10, Maximum number of plates 50. Connection Size/types: ¾” - 2” BSP M. ANTW66: Minimum number of plates 10, Maximum number of plates 150. Connection Size/types: ¾” - 2” BSP M.

Approval Holder:
Alfa Laval Ltd
Company Name
Alfa Laval Ltd
Address
Doman Road Camberley Surrey
Postcode
GU15 3DN

View All Listings by this Company

Print This Approval


#2210009

Electric, instantaneous, vented, mains water heaters with plastic housings and silicon gaskets. Model AQ5001353 incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum working pressure 1.5 bar.

Non-metallic materials and components comply with BS6920 at 98°C

Section:
1365 Heaters
Section Subtitle:
Electric instantaneous, open outlet, mains fed.
WRAS Approval Number:
2210009
Size:
3/8" BSP male inlet x 3/8" BSP male outlet. Models added March 2023: ½” BSP male inlet x 3/8” BSP male outlet.
Marking:
Aqualogic NT on body. Pressure and model on adhesive label on rear of body.
Installation Requirements:
R001
Expiry date:
31/10/2027
Model:
AQ5001352 Models added Jan 2023: AQ5001353.

Approval Holder:
Aqualogic NT Limited
Company Name
Aqualogic NT Limited
Address
20-23 Woodside Place, Glasgow
Postcode
G3 7QF
Country
United Kingdom
Phone
0141 582 1399

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 936 of 2264

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.