Unvented Heating Apparatus

Section Code 1890 :

Back To Directory Sections

#250104710

Range of stainless steel hot water buffer tanks. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.

Section:
1890 Unvented Heating Apparatus
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
2” BSP (F) 2 ½” BSP (F)
Marking:
CHWS logo, website, model no, material, capacity, temperature, pressure, manufacturing date (YYYY/WW) and other technical information on data label on body.
Installation Requirements:
R001
Expiry date:
31/01/2030
Model:
XMF 200 Litre XMF 300 Litre XMF 500 Litre XMF 800 Litre XMF 1000 Litre XMF 1500 Litre XMF 2000 Litre XMF 2500 Litre
Product Images

Approval Holder:
Commercial Hot Water Solutions Ltd.
Company Name
Commercial Hot Water Solutions Ltd.
Address
THe Hive, Beaufighter Road, Weston-Super-Mare
Postcode
BS24 8EE

View All Listings by this Company

Print This Approval


#250102704

Range of unvented storage cylinders. The secondary circuit is fitted with a temperature and pressure relief valve set at 7.0 bar at 90˚C and an expansion relief valve set at 6.0 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Also Supplied with an expansion vessel and tundish. Maximum working pressures: Primary circuit: 5.5 bar Secondary circuit: 6.0 bar Solar circuit:6.0 bar Maximum operating temperature 85.0°C

Section:
1890 Unvented Heating Apparatus
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
22mm compression all connections
Marking:
Joule, model name, capacity, pressure ratings and other technical information on adhesive label on cylinder
Installation Requirements:
R001 R140 R360
Expiry date:
31/01/2030
Model:
TRSMVD-0090LFC TRSMVD-0120LFB TRSMVD-0150LFB TRSMVD-0180LFB TRSMVD-0210LFC TRSMVD-0250LFC TRSMVD-0300LFC TRSMVI-0090LFC TRSMVI-0120LFB TRSMVI-0150LFB TRSMVI-0180LFB TRSMVI-0210LFC TRSMVI-0250LFC TRSMVI-0300LFC TRSMVS-0150LFB TRSMVS-0180LFB TRSMVS-0210LFC TRSMVS-0250LFC TRSMVS-0300LFC
Product Images

Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval


#250302708

Range of indirect unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided Maximum working pressure: Primary circuit: 6.0 Bar Secondary circuit: 5.5 bar Maximum operating temperature: 85.0°C

Section:
1890 Unvented Heating Apparatus
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Primary circuit: 1” BSP (F) Secondary circuit: 22mm compression
Marking:
Joule logo, model and technical information on adhesive label on body
Installation Requirements:
R001 R140 R360
Expiry date:
31/03/2030
Model:
TRJMVH -0150LFB 150 Cyclone Plus High Gain Indirect Standard TRJMVH -0180LFB 180 Cyclone Plus High Gain Indirect Standard TRJMVH -0210LFC 210 Cyclone Plus High Gain Indirect Standard TRJMVH -0250LFC 250 Cyclone Plus High Gain Indirect Standard TRJMVH -0300LFC 300 Cyclone Plus High Gain Indirect Standard TRJMVH -0150SFB 150 Cyclone Plus High Gain Indirect Slim TRJMVH -0180SFB 180 Cyclone Plus High Gain Indirect Slim TRJMVH -0210SFC 210 Cyclone Plus High Gain Indirect Slim
Product Images

Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval


#250402702

temperature and pressure relief valve set at 7.0 bar@90˚C. A safety kit (manifold) consisting of a check valve cartridge (verified by test, suitable for backflow protection against Fluid category 2) strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish, expansion vessel and a filling loop assembly, incorporating a stainless steel braided EPDM lined flexible hose, brass bodied isolation valve and a DZR brass non-verifiable double check valve assembly that incorporates an isolation valve. Maximum working pressures: Secondary circuit 5.5 bar. Primary circuit 3.0 bar Maximum operating temperature 90.0°C

Section:
1890 Unvented Heating Apparatus
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Secondary circuit: 22mm compression Primary circuit: 28mm compression
Marking:
World Heat, model name, max pressure, max temp and other technical information on label.
Installation Requirements:
R001 R140 R530 R360
Expiry date:
30/04/2030
Model:
150DAIKINPPR32SS 180DAIKINPPR32SS 210DAIKINPPR32SS 250DAIKINPPR32SS 300DAIKINPPR32SS 150DAIKINPPSR32SS 180DAIKINPPSR32SS

Manufacturer:
World heat Ltd
Company Name
World heat Ltd
Postcode
SK16 4RN
Country
United Kingdom
Phone
0161 343 8610

View All Listings by this Company

Print This Approval


#250402711

Mitsubishi “ECODAN” EHPT20X– MEHEW indirectly heated stainless-steel storage cylinder. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. The product is supplied with a safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, a pressure relief valve set at 6.0 bar and a pressure reducing valve set at 3.5 bar. The product is also supplied with a tundish, an expansion vessel and a filling loop assembly, consisting of a stainless-steel braided EPDM lined flexible hose, a lever operated brass spherical valve and a DZR brass double check valve assembly (suitable for backflow protection against Fluid Category 3) that incorporates a lever operated spherical valve Maximum working pressures: Secondary: 5.5 Bar Primary/CH circuit: 2.5 Bar Maximum operating temperature 75.0°C

Section:
1890 Unvented Heating Apparatus
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Secondary circuit: 22mm compression Primary circuit: 28mm compression CH circuit: 22mm compression
Marking:
Mitsubishi, model name, max pressures, max temperatures, capacity and other technical information on label on top of the cylinder.
Installation Requirements:
R001 R140 R360
Expiry date:
30/04/2030
Model:
EHPT20X– MEHEW

Manufacturer:
Mitsubishi Electric Air Conditioning Systems Europe Ltd.
Company Name
Mitsubishi Electric Air Conditioning Systems Europe Ltd.
Address
Nettlehill Road, Houston Industrial Estate, Livingston, Scotland
Postcode
EH54 5EQ
Phone
01506 - 44 55 00

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 10 of 11

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.