Section Code 1530 :
Back To Directory SectionsRange of ‘SureCal’ immersion heater elements incorporating brass or DZR heads with either a copper, stainless steel, alloy or titanium heating element and a black EPDM ‘O’-ring. Open outlet use only. Maximum operating temperature 99°C
Range of flow meters with plastic bodies. Maximum working pressure 8.0 bar Maximum operating temperature 40°C.
Range of bidet spray kits, wall outlet and brackets with brass bodies (various finishes), bidet spray kits consist of a wall outlet bracket, double interlocking flexible hose and a handset with self-closing trigger mechanism. Maximum working pressure 5 Bar. Maximum operating temperature 60°C.
Range of angled valves with chromium plated brass bodies, incorporating a non-rising spindle headwork or a quarter turn ceramic disc headwork with either triangle, cubic, single lever or dome type operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pilot operated base valves, main body only, with epoxy coated ductile iron bodies and stainless-steel plugs. Maximum working pressure IDROMEMBRANA 16.0 & HYDROMODUL 25.0 Bar Maximum operating temperature IDROMEMBRANA 50.0°C and HYDROMODUL 80.0°C.
AQUAPRO range of angled valves with chromium plated brass bodies, incorporating a non-rising spindle headwork or a quarter turn ceramic disc headwork with either cubic, single lever or dome type operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Impeller with plastic body for insertion into specifically dimensioned bores. Maximum operating temperature 65°C.
Range of pressure transmitters gauge pressure measurement devices and differential pressure measurement devices with either stainless steel or Hastelloy or Monel bodies. Maximum working pressure 66.0 Bar Maximum operating temperature 85.0°C
Water shock absorber incorporating a stainless-steel body and EPDM membrane. Maximum working pressure 15.0 bar. Maximum operating temperature 85°C.
Range of heat interface units providing heating and instantaneous hot water. The central heating and hot water are generated via plate heat exchangers. The central heating circuit contains a pressure relief valve (3.0 bar) and an expansion vessel. The cold inlet supply to the plate heat exchanger incorporates an in line single check valve assembly, (suitable for backflow protection against Fluid Category 2). Max Temperature & Pressure for models A/7892284 & B/7892283: Primary Circuit: 6.0 bar at 90°C DHW Circuit: 10.0 bar at 55°C Secondary Circuit 6.0 bar at 90°C Max Temperature & Pressure for all other models: Primary Circuit: 16.0 bar at 90*C, DHW Circuit: 10.0 bar at 65*C, Secondary Circuit 3 bar at 85*C.
Mini expansion vessels/shock arrestor with a stainless-steel body and butyl rubber diaphragm. Maximum working pressure 10.0 bar. Cold water use only.
Turbine flow sensor with plastic bodies and plastic turbines. Open outlet use only. Maximum operating temperature 23.0°C.
Range of shock arrestors with a stainless-steel body and EPDM liner. The compression connection of the X2041.015 model is for use with copper pipe (manufactured to EN1057). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Shock arrestors with a copper body, plastic shuttle and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Shock arrestors with a copper body, plastic shuttle and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Wall outlet socket with brass body. Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Compact wall outlet elbow with brass body (various finishes). Maximum operating temperature 85.0°C Open outlet use only
Range of flow sensors incorporating either brass, plastic or stainless steel bodies & EPDM ‘O’-rings. Maximum working pressure 10.0 bar for models VVXA, VVXC, VVXB. Maximum working pressure 16.0 bar for models VVXD & VVXE. Maximum operating temperature 90°C.
Range of EPDM expansion joints with flanged end conenctors. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of electromagnetic flow meters with carbon steel bodies, NBR inner liner and stainless-steel electrodes. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Page 9 of 11
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.