Directory Search Results

Print List

#250502703

‘Zip Aquapoint IV’ range of wall mounted directly heated unvented storage vessels (cased and insulated) incorporating an enamel lined cylinder and safety kit. The cylinder is factory fitted with a temperature and pressure relief valve (7.0 bar/90°C) and a drain valve. The product is supplied with an installation kit comprising of an expansion vessel, tundish and an inlet manifold incorporating a 6.0 bar expansion relief valve, an adjustable pressure reducing valve with stainless-steel strainer (adjustable between 2.7 and 3.3 bar, but pre-set at 3.0 bar), and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The compression connections of the installation kit are for use with copper pipe (Manufactured to EN 1057). Maximum working pressure 5.5 bar. Maximum operating temperature 70°C. Cold supply only.

Section:
1380 Heaters
Section Subtitle:
Electric, thermal storage, mains fed, closed outlet. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within with system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
250502703
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Aquapoint iV models: ½” BSP (M) inlet and outlets. AQ105 and AQ0108 Installation kits: 22mm compression.
Marking:
Zip on front panel. Zip company logo, model, capacity and other technical information on adhesive label on cylinder body casing.
Installation Requirements:
R001 R511
Expiry date:
31/05/2030
Model:
AP430S - 30 Ltr Direct, AP450S - 50 Ltr Direct, AP480S - 80 Ltr Direct, AP4100S - 100 Ltr Direct. All products are supplied with an installation kit, either AQ105 (AP430S and 450S models) or AQ108 (AP480S and AP4100S models).

Approval Holder:
Zip Heaters UK Ltd T/A Zip Water UK
Company Name
Zip Heaters UK Ltd T/A Zip Water UK
Address
Trafalgar House, Trafalgar Business Park, Dereham
Postcode
NR19 1JG
Country
United Kingdom
Phone
0345 600 5005
General Email
sebastian.ducker@zipwater.co.uk

View All Listings by this Company

Print This Approval


#250504715

Range of counter-top or under-sink electrical water heaters. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C, except 65°C for 10L models.

Section:
1390 Heaters
Section Subtitle:
Electric, thermal storage, mains fed, open outlet.
WRAS Approval Number:
250504715
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1/2” BSP (M)
Marking:
Flomasta on body & week of manufacture & other tech info on data label.
Installation Requirements:
R001
Expiry date:
31/05/2030
Model:
D10-20VD3 (5063022583697) 10L 2kw VD3 cover D15-20VD3 (5063022583680) 15L 2kw VD3 cover D15-30VD3 (5063022583710) 15L 3kw VD3 cover D30-30VD3 (5063022583703) 30L 3kw VD3 cover

Approval Holder:
Kingfisher International Products Ltd.
Company Name
Kingfisher International Products Ltd.
Address
3 Paddington Square, London
Postcode
W2 1GG
Phone
07721 260713
General Email
eric.capotummino@kingfisher.com

View All Listings by this Company

Print This Approval


#250602716

Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. Some models, please refer to model below, incorporate only a primary circuit. Maximum working pressures: Primary circuit: 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature both circuits: 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
250602716
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Marking:
Warmhaus on front panel. Warmhaus, product name and operating info on label on side panel
Installation Requirements:
R001 R140 R360
Expiry date:
30/06/2030
Model:
Following models are ¾” BSP M inlet/outlet primary circuit, ½” BSP M inlet/outlet secondary circuit. KM0725250101005901 EWA 2525C 25KW KM0725300101005901 EWA 2530 C 30 KW KM0725310303008701 MINERWA 25/31 COMBI BOILER IE (BLACK) KM0725300201008901 ENERWA PLUS 2530 C - UK KM0325300201001301 ENERWA PLUS 2530 C - UK + FLUE KIT KM0730350201008901 ENERWA PLUS 3035 C - UK KM0330350201001301 ENERWA PLUS 3035 C + F.KIT - DHW 35 - UK KM0735400201008901 ENERWA PLUS 3540 C - UK KM0335400201001301 ENERWA PLUS 3540 C - UK KOMBI KM0742400201001301 ENERWA PLUS 4240 C 40 KW - UK KM0745430201001301 ENERWA PLUS 4543 C 43 KW - UK KM0725310303009801 EXP.MINERWA 25 SYSTEM BOLER (BLACK) KM1220240101012201 GLOWA 2024 KM1224260101012201 GLOWA 2426 KM1228300101012201 GLOWA 2830 KM1233350101012201 GLOWA 3335 KM1220240101012401 GLOWA SMART 20/24 20KW KM1224260101012401 GLOWA SMART 24/26 24KW KM1228300101012401 GLOWA SMART 28/30 28KW KM1233350101012401 GLOWA SMART 33/35 33KW Following models are ¾” BSP M inlet/outlet and are primary circuit only KM1024000201005501 EXP.ENERWA PLUS H.O 2500H KM1024000201010201 EXP. WARMHAUS ENERWA PLUS H.O 2500H - UK KM1028000201005501 EXP.WARMHAUS ENERWA PLUS H.O 3000H KM1028000201010201 EXP.WARMHAUS ENERWA PLUS H.O 3000H - UK KM1033000201005501 EXP.WARMHAUS ENERWA PLUS H.O 3500H KM1033000201010201 EXP.WARMHAUS ENERWA PLUS H.O 3500H - UK KM1133000201005501 EXP.WARMHAUS ENERWA PLUS H.O 3500H+F.KIT KM1133000201006201 EXP.WARMHAUS ENERWAPLUS HO 3500H-D+F.KIT KM1142000201005501 ENERWA PLUS H.O 4200H KM1145000201005501 ENERWA PLUS H.O 4500H KM1220000101012301 GLOWA 20 H.O. KM1224000101012301 GLOWA 24 H.O. KM1228000101012301 GLOWA 28 H.O. KM1233000101012301 GLOWA 33 H.O.

Manufacturer:
Warmhaus Isitma VE Sogutma Sistemleri Sanayi Ticaret A.S.
Company Name
Warmhaus Isitma VE Sogutma Sistemleri Sanayi Ticaret A.S.
Address
Nilufer Organise Sanayi Bolgesi Selvi Cad No:3 Nilufer Bursa Turkey
Phone
+90-224-2959400

View All Listings by this Company

Print This Approval


#250602045

Range of water meters with brass and plastic bodies and plastic turbines. The inlet incorporates a plastic filter Maximum working pressure 16.0 Bar Maximum operating temperature 50.0°C

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
¾” to 2 ½” BSP M (G models) DN 50 flanged (FL Models)
Marking:
Zenner logo, Model, ZR, CE, date of manufacture (YYYY) and other information on faceplate. Flow arrow and date of manufacture (YYYY) on body.
Installation Requirements:
R001 R008
Expiry date:
30/06/2030
Model:
145118 MTKD-M 2,5-165-G ¾ B (½) 144835 MTKD-M 4-190-G 1 B (¾) 145132 MTKD-M 6,3-260-G 1 ¼ B (1) 144837 MTKD-M 10-260-G 1 ¼ B (1) 145115 MTKD-M 10-260-G 1 ½ B (5/4) 145117 MTKD-M 16-300-G 2 B (6/4) 174240 MTKD-M 25-270-G 2 ½ B (2) 145446 MTKD-M 25-300- G 2 ½ B (2) 145448 MTKD-M 25-270-FL 145447 MTKD-M 25-300-FL 134886 MTKD-L-M 2,5-165-G ¾ B (½) 147662 MTKD-L-M 4-190-G 1 B (¾)

Manufacturer:
Zenner International Gmbh & Co. KG
Company Name
Zenner International Gmbh & Co. KG
Address
Heinrich‐Barth‐Str. 29, 66115 Saarbrücken, Germany
Country
Germany

View All Listings by this Company

Print This Approval


#240902088

Range of ‘Tcontrols’ immersion heater elements incorporating brass or DZR heads with either a copper, stainless steel, alloy or titanium heating element and a black EPDM ‘O’-ring. Open outlet use only. Maximum operating temperature 99°C

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
RT – 1.1/4” BSP (M) to 2.1/4” BSP (M) RF – 48 mm OD
Marking:
"Tcontrols" logo, Model, Voltage, Size and other information on cap.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
Model Code: XXYZS Where XX denotes the boss type and can be replaced with any of the following: RT = Thread Type RF = Flange Type Where Y denotes the heating tube material and can be replaced with any of the following: 1 = Copper 2 = AISI 304 / AISI 304L 3 = AISI 321 4 = AISI 316 / AISI 316L 5 = Alloy 800 / Alloy 825 / Alloy 840 6 = Titanium 7 = AISI 309S 8 = AISI 310 Where Z denotes the brazing system and can be replaced with any of the following: A = Tin Alloy B = Silver Alloy C = Itek Brazing Where S denotes the surface enamelling and can be replaced with either of the following: S = Enamelled Blank = Not Enamelled

Approval Holder:
Thermowatt S.p.A.
Company Name
Thermowatt S.p.A.
Address
Via San Giovanni Battista 21 Arcevia
Postcode
60011
Country
Italy
Phone
+39 0731988246
General Email
thermowatt@legalmail.it

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 793 of 813

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.