Range of WC dual flush drop valves with ABS bodies and silicone seals. The valves are operated via a two push button assembly for either full or reduced flush and incorporate an internal overflow. Cold water use only.
Single flush WC outlet valves with an ABS plastic body (WC01), operated via a mains powered infra red sensor assembly (WC03). Cold water use only.
Range of syphonic flush valves with plastic bodies. Cold water only
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not be verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
Range of manually operated and sensor operated dual flush WC outlet valves. Cold water use only.
Range of plate heat exchangers with stainless steel plate bodies and copper brazing. Maximum working pressure: 45 Bar. Maximum operating temperature: 99 °C.
Range of water meters with brass bodies and plastic turbines. The inlet incorporates a plastic filter. Maximum working pressure 16.0 bar. Maximum operating temperatures - SJ-SDC plus DN15-25 models: 50°C, SJ-SDC plus DN32-40 models: 85°C.
Range of water meters with plastic bodies and plastic or brass threads (see models). Maximum working pressure 16.0 Bar Cold water use only.
Range of water meters with blue epoxy coated ductile iron body, incorporating an EPDM diaphragm, NBR ‘O’ rings, stainless steel strainer and a polypropylene rotor. The products incorporate a second bypass meter assembly and a check valve cartridge (however, the complete product has not been fully tested for and is not intended to provide backflow protection). Maximum working pressure 16.0 Bar. Cold water use only.
Range of ultrasonic water meters with blue epoxy coated cast iron bodies, EPDM ‘O’-rings and plastic flow straighteners. Maximum working pressure 16.0 bar (DN50 to 200) or 10.0 bar (DN200 only)
Non-metallic materials and components comply with BS6920 at 50°C
Page 719 of 1110
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.