Directory Search Results

Print List

#240902702

Range of WC dual flush drop valves operated via a two-push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not been verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
240902702
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Ø59 mm
Marking:
Xiamen NAT Plumbing Logo on body
Installation Requirements:
R001 R571 R572 R582
Expiry date:
30/09/2029
Model:
NB209 & NB208
Product Images

Approval Holder:
XIAMEN NAT PLUMBING INC.
Company Name
XIAMEN NAT PLUMBING INC.
Address
3RD FLOOR, BLDG.4, WEST HOUXIANG ROAD, HAICANG, XIAMEN, P.R.CHINA H
Phone
+86-592-6538317

View All Listings by this Company
Manufacturer:
XIAMEN NAT PLUMBING INC.
Company Name
XIAMEN NAT PLUMBING INC.
Address
3RD FLOOR, BLDG.4, WEST HOUXIANG ROAD, HAICANG, XIAMEN, P.R.CHINA H
Phone
+86-592-6538317

View All Listings by this Company

Print This Approval


#240904726

‘PREMIX’ range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both the domestic hot water and primary circuit are controlled via spherical valves. Maximum working pressures: Primary circuit: 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature both circuits: 80°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240904726
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
22mm compression (Primary Circuit) 15mm compression (Secondary Circuit)
Marking:
E.C.A. on front cover. E.C.A, model and technical information including KW rating on adhesive label on body.
Installation Requirements:
R001 R360
Expiry date:
30/09/2029
Model:
8116350010 CALORA PREMIX 24 HM ERP UK 8116484110 CALORA PREMIX 14 HM ERP UK 8116487110 CALORA PREMIX 20 HM ERP UK 8116356010 CALORA PREMIX 28 HM ERP UK 8116389010 CITIUS PREMIX 14 HM ERP UK 8116392010 CITIUS PREMIX 20 HM ERP UK 8116353010 CITIUS PREMIX 24 HM ERP UK 8116380010 CITIUS PREMIX 28 HM ERP UK 8116576110 Proteus Premix 42 HM DG ERP UK 8116550010 Proteus Premix 45 HM DG ERP UK
Product Images

Approval Holder:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Mustafa Kemal Blv. No:13 Keçiliköy Osb/Yunusemre Manisa
Postcode
45030
Country
Turkey
General Email
egecakmakci@emas.com.tr

View All Listings by this Company
Manufacturer:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Mustafa Kemal Blv. No:13 Keçiliköy Osb/Yunusemre Manisa
Postcode
45030
Country
Turkey
General Email
egecakmakci@emas.com.tr

View All Listings by this Company

Print This Approval


#240902069

Range of in-line water meters with plastic bodies. The inlet incorporates a plastic filter. Maximum working pressure; 16 Bar Maximum operating temperature 50°C

Section:
1505 Water Meters
WRAS Approval Number:
240902069
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
All models available in body lengths of 165, 170 and 190mm
Size:
1" BSP (M)
Marking:
Arad logo, Model and technical information on faceplate. Flow arrow on body.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
PD GLADIATOR Q3=4 1124XXXX With 3P register 1132XXXX- With 3G register
Product Images

Approval Holder:
Arad GROUP Ltd.
Company Name
Arad GROUP Ltd.
Address
Kibbutz Dalia 1923900 Kibutzz Dalia
Country
Israel
Phone
+972-4-9897906
General Email
Dars@arad.co.il

View All Listings by this Company
Manufacturer:
Arad GROUP Ltd.
Company Name
Arad GROUP Ltd.
Address
Kibbutz Dalia 1923900 Kibutzz Dalia
Country
Israel
Phone
+972-4-9897906
General Email
Dars@arad.co.il

View All Listings by this Company

Print This Approval


#240704057

Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M).
Marking:
CIM & Made in Italy on body.
Installation Requirements:
R001
Expiry date:
31/07/2029
Model:
CIM 1450 – Water Hammer shock absorber

Approval Holder:
Cimberio S.p.A
Company Name
Cimberio S.p.A
Address
Via Torchio, 57 San Maurizio d’Opaglio
Postcode
28017
Country
Italy
Phone
+39.0322.923001
General Email
tguidetti@cimberio.it

View All Listings by this Company

Print This Approval


#240902039

Range of VEGAPULS radar sensors for level measurement with plastic bodies. Cold water use only. Open outlet use only.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See model key
Marking:
VEGA logo date of manufacturer (YYYY), serial number and other technical data on body
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
PSC21.ab-c-d-N-f-g-h-I VEGAPULS C 21 PSC22.ab-c-d- N -f-g-h-I VEGAPULS C 22 PSC23.ab-c-d- N -f-g-h-I VEGAPULS C 23 PS21.ab-c-d- N -f-g-h-I VEGAPULS 21 PS31.ab-c-d- N -f-g-h-I VEGAPULS 31 KEY FOR VEGAPULS C 21 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; G Thread G1½ / G1 N Thread 1½NPT / 1NPT R Thread R1½ / R1 g = Cable material / Length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 22 ab = Explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignition proof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as: X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 23 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; F Thread G1 M Thread 1NPT Q Thread R1 g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS 21 / 31 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) AX without, for Ex-free area (CE, UKCA, RCM) VC ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) SC EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 TC CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 WC INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 c = Approved as overfill protection, which can be displayed as; X Without W With (WHG, VLAREM) d = Ship approval, which can be displayed as; X Without S With (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff/Pharmaceutical certificate, which can be displayed as X Without N With (NSF/ANSI/CAN 61) P With (NIH) F With (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable entry / connection, which can be displayed as; M M20x1.5 / Cable gland PA black (ø5-9mm), standard h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART i = Sensor setting via smartphone and VEGA Tools app X Without B With
Product Images

Approval Holder:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company
Manufacturer:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
Country
Germany
General Email
info.de@vega.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 629 of 825

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.