| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 48 712 xx0 | Various | basic set 48710180 | 10 bar | 60 °C | AXOR | on the handle | Yes | Ceramic cartridge | Not Applicable | ||
| 48 722 xx0 | Various | basic set 48710180 | 10 bar | 60 °C | AXOR | on the handle | Yes | Ceramic cartridge | Not Applicable | ||
| 48 713 xx0 | Various | basic set 48720180 | 10 bar | 60 °C | AXOR | on the handle | Yes | Ceramic cartridge | Not Applicable | ||
| 48 723 xx0 | Various | basic set 48720180 | 10 bar | 60 °C | AXOR | on the handle | Yes | Ceramic cartridge | Not Applicable | ||
| 48 710 180 | NA | G 1/2 | 10 bar | 60 °C | hansgrohe | embossed on the body | Yes | Ceramic cartridge | |||
| 48 720 180 | NA | G 1/2 | 10 bar | 60 °C | hansgrohe | embossed on the body | Yes | Ceramic cartridge |
Where xx0 denotes the surface finish (which is a non-water contact part). It will always be 3 digits, which can be any combination of numbers and/or letters, as examples: 000 = chrome optic finish, 800 = PVD stainless steel optic finish. Product needs to be installed with the dedicated basic set.
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| RNDSCBV2.MB | Matt Black | ½”x ¾” BSP (M) offset unions or 15mm compression | 5.0 bar | 65 °C | Aqualisa | Valve Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | Flow Regulator Fitted, Shower Hose, Handset, Fixed Head, Riser Rail, |
| AQ150BAR2 | Chrome | ½”x ¾” BSP (M) offset unions or 15mm compression | 5.0 bar | 65 °C | Aqualisa | Valve Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | Flow Regulator Fitted, Shower Hose, Handset, Fixed Head, Riser Rail, |
| 300RSC | Chrome | ½”x ¾” BSP (M) offset unions or 15mm compression | 5.0 bar | 65 °C | Aqualisa | Valve Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | Flow Regulator Fitted, Shower Hose, Handset, Fixed Head, Riser Rail, |
| TWBAR2.21 | Chrome | ½”x ¾” BSP (M) offset unions or 15mm compression | 5.0 bar | 65 °C | Aqualisa | Valve Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | Flow Regulator Fitted, Shower Hose, Handset, Fixed Head, Riser Rail, |
| AQ150BAR2.MB | Matt Black | ½”x ¾” BSP (M) offset unions or 15mm compression | 5.0 bar | 65 °C | Aqualisa | Valve Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | Flow Regulator Fitted, Shower Hose, Handset, Fixed Head, Riser Rail, |
| TS150BAR2 | Chrome | ½”x ¾” BSP (M) offset unions or 15mm compression | 5.0 bar | 65 °C | Aqualisa | Valve Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | Flow Regulator Fitted, Shower Hose, Handset, Fixed Head, Riser Rail, |
| 126HP | Chrome | ½”x ¾” BSP (M) offset unions or 15mm compression | 5.0 bar | 65 °C | Aqualisa | Valve Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | Flow Regulator Fitted, Shower Hose, Handset, Fixed Head, Riser Rail, |
| 126HP.MB | Matt Black | ½”x ¾” BSP (M) offset unions or 15mm compression | 5.0 bar | 65 °C | Aqualisa | Valve Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | Flow Regulator Fitted, Shower Hose, Handset, Fixed Head, Riser Rail, |
| AQSQBAR2 | Chrome | ½”x ¾” BSP (M) offset unions or 15mm compression | 5.0 bar | 65 °C | Aqualisa | Valve Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | Flow Regulator Fitted, Shower Hose, Handset, Fixed Head, Riser Rail, |
| TSSQBAR2 | Chrome | ½”x ¾” BSP (M) offset unions or 15mm compression | 5.0 bar | 65 °C | Aqualisa | Valve Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | Flow Regulator Fitted, Shower Hose, Handset, Fixed Head, Riser Rail, |
| 408HP | Chrome | ½”x ¾” BSP (M) offset unions or 15mm compression | 5.0 bar | 65 °C | Aqualisa | Valve Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | Flow Regulator Fitted, Shower Hose, Handset, Fixed Head, Riser Rail, |
| 300SSC | Chrome | ½”x ¾” BSP (M) offset unions or 15mm compression | 5.0 bar | 65 °C | Aqualisa | Valve Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | Flow Regulator Fitted, Shower Hose, Handset, Fixed Head, Riser Rail, |
| AQSQBAR2.MB | Matt Black | ½”x ¾” BSP (M) offset unions or 15mm compression | 5.0 bar | 65 °C | Aqualisa | Valve Body | No | 1/4 Turn ceramic disk | Not Applicable | Not Applicable | Flow Regulator Fitted, Shower Hose, Handset, Fixed Head, Riser Rail, |
The “*” is for a different Overhead Shower, Shower Hose or Shower Handset, which represent the letters A to Z X XXX Denotes the following: First X: Different handle The second, third & fourth XXX for different finishes: Chrome – No suffix, Brushed brass – BGP, PVD Gold – PVD, Brushed Nickel – BN1, Gun Metal – GMG, Matt Black – MBK, Matt White – MWH, Stainless Steel – SS1, Black Chrome – BCP, Titanium – TIB and Antique Bronze – AB1.
2101 Range of butterfly valves with blue epoxy coated ductile iron bodies, stainless-steel discs and PTFE seats. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of pilot operated pressure reducing valves with ductile iron bodies (blue epoxy coating) and EPDM diaphragm and O-rings. The products are supplied with auxiliary fittings: spherical valves (bronze or stainless steel), pressure gauges, a pilot valve, a needle valve and stainless steel or copper tubes. Maximum inlet supply pressure 16.0 bar. The outlet pressure is adjustable between 0.67~16.0 bar. Maximum operating temperature 85°C.
Range of spherical valves incorporating brass bodies and ball. Maximum working pressure see models. Maximum operating temperature 100°C.
Page 624 of 640
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.