Directory Search Results

Print List

#241102718

Range of pumps with stainless steel bodies. Maximum working pressure depends on model, please refer to model. Maximum operating temperature 65°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241102718
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Please refer to model.
Marking:
Clarke Pump, model & technical info on label.
Installation Requirements:
R001 R415
Expiry date:
30/11/2029
Model:
MHS90 4M MSP490: G1” BSP F (4.3bar). MHS90 5M MSP590: G1” BSP F (5.3bar). MHS90 6M MSP690: G1” BSP F (6.4bar). MHS120 4M MSP4120: G1¼” BSP F X G1” BSP F (4.5bar). MHS120 5M MSP5120: G1¼” BSP F X G1” BSP F (5.7bar). MHS120 6M MSP6120: G1¼” BSP F X G1” BSP F (6.9 bar).

Approval Holder:
Clarke International Limited
Company Name
Clarke International Limited
Address
Sealand House, Hemnall Street, Epping, Essex, CM16 4LG UK

View All Listings by this Company

Print This Approval


#241104704

Range of booster sets consisting of two or four electronically controlled pumps, stainless steel manifold, spherical valves, expansion vessels and pressure gauge/transducers and non-return valves. Maximum operating pressure 16 bar. Maximum operating temperature 23°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241104704
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1 ½” BSP (M) x 2” BSP (M) to 2" BSP (M) x 4" BSP (M).
Marking:
Stuart Turner, Dutypoint or Flowtech on control panel.
Installation Requirements:
R001 R415
Expiry date:
30/11/2029
Model:
Stuart Turner Version: SPAV-B-C-D/E Where; A = number of pumps – 2,3,4. B = Pump Model Code based on supplier models – Lowara examples 3HM06S/5SV08, Ebara example 0306, Stuart Turner Example HM0306. (Code changes based on pump flow rate & number of stages). C = controller type – MAB or MARB. D = power input – 1 phase or 3 phase. E = vessel capacity – 24L, 48L or 72L. Dutypoint Version VGA-BC-DE-F Where; A = Number of pumps - 2, 3 or 4 B = Nominal flow per pump - 05 = 5m3 C = Number of stages per pump - 06 = 6 stages D = kW size - 011 = 1.1kw E = Voltage - T = 3 phase, M = 1 phase F = Controller Type - MAB or MARB Flowtech Version: AVA-BC-DE-F Where; A = Number of pumps - 2, 3 or 4 B = Nominal flow per pump - 06 = 5m3 C = Number of stages per pump - 09 = 9 stages D = kW size - 011 = 1.1kw E = Voltage - T = 3 phase, M = 1 phase F = Controller Type - MAB or MARB

Approval Holder:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Unit A, Quedgeley West Business Park, Hardwicke, Gloucester
Postcode
GL2 4PA
Country
United Kingdom
Phone
01452313334
General Email
austin.hill@dutypoint.com

View All Listings by this Company

Print This Approval


#241104706

Circulation pump with a stainless steel body. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241104706
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1½” BSP (M)
Marking:
Archergas, model and technical information on case. Flow arrow on body.
Installation Requirements:
R001
Expiry date:
30/11/2029
Model:
DHW15 Circulation Pump.

Approval Holder:
Archergas Limited
Company Name
Archergas Limited
Address
85 Bayham Street, Camden Town

View All Listings by this Company

Print This Approval


#241207701

‘UPM10’ and ‘UPM20’ range of circulator pumps with a stainless-steel body, plastic impellor and EPDM ‘O’-rings. The product is supplied with EPDM gaskets for the inlet and outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241207701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1½” BSP (M) inlet/outlet.
Marking:
Grundfos and Grundfos logo, type and model on nameplate on motor housing. P/N no., P/C no., Serial (S/N) no., technical info, manufacturing country and data matrix on end of motor housing. Flow arrow on body.
Installation Requirements:
R001
Expiry date:
31/12/2029
Model:
UPM 10M 25-95 N 180, UPM 10L 25-105 N 180, UPM 10XL 25-125 N 180, UPM 20S 25-145 N 180. Where: Pump type: UPM 10M, UPM 10L, UPM 10XL, UPM 20S. Control variant: []: PWM, LIN: LIN bus input signal, 0-10V, AUTO, HYBRID, SOLAR, DHW. Nominal diameter: 25: G 1½”. Max. Head: 95: 9.5m, 105: 10.5m, 125: 12.5m, 145: 14.5m. Designation/Pump housing: N 180: Stainless steel body, 180mm port to port length. Control box orientation: 3: 3 o’clock (right), 6: 6 o’clock (below), 9: 9 o’clock (left). Customer code: XXX (no impact on water contact parts).

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#241107701

Self-priming single stage pump, with stainless steel body, plastic impellers, stainless steel shaft, NBR 'O'-rings and seals. Maximum working pressure 6.0 bar. Maximum operating temperature 45°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
241107701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1” BSP (F).
Marking:
Grundfos and Grundfos logo on body. Grundfos and Grundfos logo, type, model number, product/version number, technical information, serial number and manufacturing location on adhesive label on motor housing.
Installation Requirements:
R001 R008 R415
Expiry date:
30/11/2029
Model:
99458789: JP 4-54 1X230V 50Hz 1,5M UK HU IE2.

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 596 of 892

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.