Directory Search Results

Print List

#2112329

WC flushing cistern incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3 litres and incorporates a servicing valve and flexible hose on the inlet supply.The cistern is operated by a pnuematic push button Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2112329
Size:
½” BSP (M)
Marking:
Geberit on cistern and inlet valve.
Installation Requirements:
R001 R556
Expiry date:
31/12/2026
Model:
109.103.21.2 109.104.21.2 109.105.00.1 458.118.21.2 458.119.21.2 458.132.00.1 Model added May 2023: 458.145.00.1 Models added March 2024: 458.151.21.1 458.152.21.1
Product Images

Approval Holder:
Geberit Sales Ltd.
Company Name
Geberit Sales Ltd.
Address
Geberit House, Edgehill Drive, Warwick
Postcode
CV34 6NH
Country
United Kingdom
Phone
01926516800
General Email
enquiries@geberit.co.uk

View All Listings by this Company

Print This Approval


#2112010

Concealed WC dual flushing cistern with a BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush valve is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure - 10 Bar, cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2112010
Size:
1/2" BSP (M)
Marking:
Geberit on push buttons, 6 litres inside cistern.
Installation Requirements:
R001 R280 R556
Expiry date:
31/12/2026
Model:
Geberit Concealed Cistern Type 720
Product Images

Approval Holder:
Geberit Sales Ltd.
Company Name
Geberit Sales Ltd.
Address
Geberit House, Edgehill Drive, Warwick
Postcode
CV34 6NH
Country
United Kingdom
Phone
01926516800
General Email
enquiries@geberit.co.uk

View All Listings by this Company

Print This Approval


#2109063

Range of WC flushing cisterns incorporating a BS 1212-4 (2016) side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres or 4.5/3 litre flush volumes. The cistern is operated by a manual push button and the product incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2109063
Size:
15mm Compression
Marking:
Noken Porcelanosa, model and flushing volumes inside of cistern. Noken on operating buttons.
Installation Requirements:
R001 R556
Expiry date:
30/09/2026
Model:
100294206 & 100294199 WC CISTERN

Approval Holder:
Noken Design S.A.U
Company Name
Noken Design S.A.U
Address
CV-20 Km2 VILA-REAL CASTELLON
Postcode
12540
Country
Spain
General Email
certificaciones@noken.com

View All Listings by this Company

Print This Approval


#2107109

Range of floor mounted, single hole, single outlet (fixed), combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator (SH-T9050N model) or a plastic flow straightener (all other models). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
0675 Combination Tap Assemblies
Section Subtitle:
Multi-hole tap(s) with a single outlet and a fixed spout, incorporating a self-cancelling diverter to a shower outlet.
WRAS Approval Number:
2107109
Note:
This approval does not include a shower hose and handset.
Size:
M12 (F)
Marking:
QIXI and WRAS on base plate.
Installation Requirements:
R001 R020
Expiry date:
31/07/2026
Model:
SH-T8170BN, SH-T8530M, SH-T8810M, SH-T9050N.

Approval Holder:
Zhejiang Qixi Sanitary Co., Ltd
Company Name
Zhejiang Qixi Sanitary Co., Ltd
Address
Huxin Industrial Area, Chumen Yuhuan Zhejiang
Country
China
Phone
189 685 872 326
General Email
syyzhuang@coralbathroom.com

View All Listings by this Company
Manufacturer:
Zhejiang Qixi Sanitary Co., Ltd
Company Name
Zhejiang Qixi Sanitary Co., Ltd
Address
Huxin Industrial Area, Chumen Yuhuan Zhejiang
Country
China
Phone
189 685 872 326
General Email
syyzhuang@coralbathroom.com

View All Listings by this Company

Print This Approval


#2201067

‘Polytank’ wholesome water kit for use with water storage cisterns for domestic purposes. The products have black plastic bodies and consist of a warning pipe elbow incorporating a (white plastic) screen, breather incorporating a (white plastic) screen, vent pipe incorporating a (white plastic) screen, dip tube, plastic washer and backplate. Cold water use only.

Section:
0085 Wholesome water kits for use with cold water storage
Section Subtitle:
Wholesome water kits for use with Cold water storage cisterns to comply with Schedule 2. Section 7, Paragraph 4. of the Water Supply (Water Fittings) Regulations 1999.
WRAS Approval Number:
2201067
Note:
The BL30/1 SWPE (natural) plastic backnut washer must be installed externally of the cistern.
Size:
BL30/1: ¾" BSP (M)/22mm compression. BL30/2 & BL30/3: ¾" BSP (M).
Marking:
Polytank and model on body.
Installation Requirements:
R001 R008
Expiry date:
31/01/2027
Model:
BL30/1 screened waring pipe elbow. BL30/2 screened breather. BL30/3 screened vent. BL30/4 dip tube. BL30/5 polypropylene washer. BL30/7 polypropylene backplate.
Product Images

Approval Holder:
Polytank Group Ltd
Company Name
Polytank Group Ltd
Address
Naze Lane East Freckleton Preston
Postcode
PR4 1UN
Phone
+44 (0) 1772 632850
General Email
sales@polytank.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 568 of 2236

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.