Section Code 1180 : Couplings. Unless specified in the individual approval, the products within this section are not suitable for below ground use
Back To Directory SectionsRange of stainless steel (SS316L) pressfit fittings with EPDM ‘O’-rings for use with stainless steel pipe (manufactured to EN10312). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of copper crimped fittings with EPDM ‘O’-rings for use with copper pipe manufactured to EN1057. For above and below ground use. Maximum working pressure 16 Bar. Maximum operating temperature 99°C.
Range of plastic, push-fit fittings (wall plate elbow, equal elbow, end stop, pipe insert, equal straight and equal tee) for use with MDPE pipe (manufactured to BS EN 12201), for above and below ground use. Copper adaptors are for use with PB pipe (manufactured to BS7291-2), PEX pipe (manufactured to BS7291-3) or Copper pipes (manufactured to BS EN 1057) and are for above ground use only. Maximum working pressure 16.0 bar. Cold water use only.
‘Universal Transition Coupling (UTC)’ range of plastic compression fittings for use with the following pipe types and sizes: Stainless steel (manufactured to ASTM A554/ BS EN 10312): ¾”, 1” & 1¼”. Galvanised (EN 10255): ¾”, 1”, 1¼”, 1½” & 2”. Copper (BS EN 1057): 15mm, 22mm & 28mm. PVC (BS EN 1452): 20mm & 2”. ABS (BS 5391-1): 20mm, 25mm & 32mm. PE80 & PE100 pipe (to BS EN 12201): 20mm, 25mm, 32mm, 50mm & 63mm. For use above and below ground. Maximum working pressure 12.5 bar. Cold water use only.
Range of brass press fittings for use with copper pipe (manufactured to EN1057:2006 and +A1:2010 Seamless round copper tube, R250 half hard). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of Copper and Brass push fit fittings. Brass fittings are for use with PB pipe (manufactured to BS7291-2) & Copper pipe (manufactured to BS EN 1057) only. Copper fittings are for use with PB pipe (manufactured to BS7291-2), PE-X pipe (manufactured to BS7291-3) & Copper pipe (manufactured to BS EN 1057). Maximum working pressures and operating temperatures when used with: PB & PEX pipe – 3.0 bar and 92°C, 20.0 bar cold water. Copper pipe – 20.0 bar and 100°C.
Flomasta Range of plastic, push-fit fittings (wall plate elbow, equal elbow, end stop, pipe insert, equal straight and equal tee) for use with MDPE pipe (manufactured to BS EN 12201), for above and below ground use. Copper adaptors are for use with PB pipe (manufactured to BS7291-2), PEX pipe (manufactured to BS7291-3) or Copper pipes (manufactured to BS EN 1057) and are for above ground use only. Maximum working pressure 16.0 bar. Cold water use only.
Flomasta Range of Copper and Brass push fit fittings. Brass fittings are for use with PB pipe (manufactured to BS7291-2) & Copper pipe (manufactured to BS EN 1057) only. Copper fittings are for use with PB pipe (manufactured to BS7291-2), PE-X pipe (manufactured to BS7291-3) & Copper pipe (manufactured to BS EN 1057). Maximum working pressures and operating temperatures when used with: PB & PEX pipe – 3.0 bar and 92°C, 20.0 bar cold water. Copper pipe – 20.0 bar and 100°C.
Range of DZR brass push fit fittings for use with copper pipe (EN1057). Maximum working pressure 10.0 Bar. Maximum operating temperature 65 °C.
Range of copper press fittings with EPDM rubber ‘O’-rings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Twistloc’ range of push-fit fittings with PEX-b, polysulphone or PPE bodies, supplied with polysulphone inserts. For use with PEX pipe (manufactured to BSEN 7291 part 3), PB (manufactured to BSEN 7291 part 2) and copper pipe (EN1057). Maximum working pressure/temperature: 12.5 Bar @ 20°C. As of October 2025: Maximum working pressure/temperature 3 Bar @ 92°C.
‘HDE-210xxx-xx’ range of brass press-fit fittings incorporating EPDM ‘O’-rings for use with copper pipes (manufactured to EN1057). Jointing is achieved via a crimping tool using a ‘M’ profile. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of brass press fittings for use with copper pipe (manufactured to EN1057:2006 and +A1:2010 Seamless round copper tube, R250 half hard). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
‘AF’ range of compression fittings with brass or chrome plated brass bodies for use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum working temperature 85˚C
Range of Victaulic rigid couplings (905, H10, H11, H20, H50) for use with plain end HDPE pipe (EN 12201-2), and for product 907, for use with EN 12201-2 HDPE and EN 10217-1 steel pipe. For above and below ground use. Maximum working pressure: SDR7.4 25bar, SDR11 16bar or SDR17 10bar. Maximum operating temperature: Cold water use only.
Range of polypropylene push-fit fittings and inserts for use with PE80 MDPE pipe (manufactured to BS EN 12201). For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Range of metric and imperial PVC-U Solvent cement or Threaded fittings for use with PVC-U pressure pipe Class E manufacture to BS EN 1452 Maximum working pressure; 16 Bar Maximum operating temperature; Cold water only
"PRESSTITE" range of press fittings with nickel plated brass bodies incorporating EPDM ‘O’-rings and stainless steel crimp sleeves for use with PEX/AL/PEX multilayer pipe (manufactured to EN ISO 21003). Jointing is achieved by a TH crimping profile. For above ground use only. Maximum working pressure 10.0 bar. 20 & 26mm pressfit sizes cold water use only. Threaded and pressfit 16mm size maximum operating temperature 95°C. From June 2025: The 20 & 26mm pressfit sizes maximum operating temperature 95°C.
Range of stainless-steel press fittings (SUS304 or 316L) with EPDM ‘O’-rings for use with stainless-steel pipe (SUS304 or 316L EN 10312), using an ‘M’ press profile. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
‘F17’ range of brass press fittings with EPDM ‘O’-rings for use with PEX/AL/PEX multilayer pipe (manufactured to EN ISO 21003). Jointing is achieved via a crimping tool using either a ‘U’, ‘TH’ or ‘H’ profile. Maximum working pressure 10.0 bar. Cold water use only.
Page 5 of 7
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.