Directory Search Results

Print List

#250712005

Range of gate valves with blue epoxy ductile iron bodies, ductile iron wedge encapsulated in EPDM. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.

Section:
2290 Valves
Section Subtitle:
Stop, gate, metal.
WRAS Approval Number:
250712005
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
¾”, 1”, 1 ¼”, 1 ½” & 2” BSP (F)
Marking:
IVALVE Logo, Size (DN), PN. Date of Manufacture (YY/MM) or (YY/MM/DD) & GGG50 on body.
Installation Requirements:
R001
Expiry date:
31/07/2030
Model:
IV049

Approval Holder:
IVALVE Tech. (Tongling) Co., Ltd
Company Name
IVALVE Tech. (Tongling) Co., Ltd
Address
No.97 Jinqiao Avenue, Yi'an District Economic Development Zone, Tongling City, Anhui
Country
China

View All Listings by this Company

Print This Approval


#250702029

Range of gate valves with blue epoxy coated ductile iron bodies, EPDM coated ductile iron wedge and EPDM seals. Valves are operated via a non-rising spindle headwork. Maximum working pressure 16.0 Bar Maximum operating temperature 100.0°C

Section:
2290 Valves
Section Subtitle:
Stop, gate, metal.
WRAS Approval Number:
250702029
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DN40 to DN400 Flanged
Marking:
Xingda logo, size and pressure on body
Installation Requirements:
R001
Expiry date:
31/07/2030
Model:
Z45X

Manufacturer:
Yantai Xingda Valve Co Ltd
Company Name
Yantai Xingda Valve Co Ltd
Address
No. 1,Hengye Road, Qingyang Industrial Park, Fushan District, Yantai City, Shandong Province

View All Listings by this Company

Print This Approval


#250715004

Range of resilient seated gate valves with blue epoxy coated ductile iron bodies, EPDM coated ductile iron wedges and a handwheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.

Section:
2290 Valves
Section Subtitle:
Stop, gate, metal.
WRAS Approval Number:
250715004
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DN50 - DN300 flanged.
Marking:
Chizhou Fuchang Machinery Manufacturing Co., Ltd. logo (‘FCV’), size, PN and GGG50 on body.
Installation Requirements:
R001
Expiry date:
31/07/2030
Model:
F4.

Approval Holder:
Chizhou Fuchang Machinery Manufacturing Co., Ltd.
Company Name
Chizhou Fuchang Machinery Manufacturing Co., Ltd.
Address
Xinhe Industrial Zone, Qingyang County, Chizhou City, Anhui Province
Country
China

View All Listings by this Company
Manufacturer:
Chizhou Fuchang Machinery Manufacturing Co., Ltd.
Company Name
Chizhou Fuchang Machinery Manufacturing Co., Ltd.
Address
Xinhe Industrial Zone, Qingyang County, Chizhou City, Anhui Province
Country
China

View All Listings by this Company

Print This Approval


#2110152

Range of compression stop valves incorporating brass bodies, rising spindle headworks and EPDM gaskets. For use with copper pipe manufactured to BS EN 1057 (15mm, 22mm and 28mm) or PE pipe manufactured to BS EN 12201-2 (20mm and 25mm). Maximum working pressure 10.0 bar. Cold water use only.

Section:
2310 Valves
Section Subtitle:
Stop, metal, screw down.
WRAS Approval Number:
2110152
Size:
See model
Marking:
'MWM’, Size, Arrow on body.
Installation Requirements:
R001
Expiry date:
31/10/2026
Model:
ST1515: 15mm compression ST2222 : 22mm compression. ST2828 : 28mm compression. ST1520 : 15mm x 20mm compression. ST1525 : 15mm x 25mm compression. ST2225 : 22mm x 25mm compression. ST2020 : 20mm x 20mm compression. ST2025 : 20mm x 25mm compression. ST2525 : 25mm x 25mm compression.

Approval Holder:
MWM Distributors Ltd
Company Name
MWM Distributors Ltd
Address
52-53 Enfield Industrial Estate Enfield, Redditch
Postcode
B97 6DE
Country
United Kingdom
General Email
martin@mwmdistributorsltd.com

View All Listings by this Company

Print This Approval


#250704012

Range of 2, 3 ,4 or 5 way manifolds incorporating brass bodies, stop valves and EPDM O-rings, to be used with copper pipe to BS EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
2310 Valves
Section Subtitle:
Stop, metal, screw down.
WRAS Approval Number:
250704012
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See models.
Marking:
Poletti, Made in Italy & size on body.
Installation Requirements:
R001
Expiry date:
31/07/2030
Model:
C322N00_* Modular manifold with shut-off valve, size ¾”, connection ½”, 2 ways ¾” C322N02_* Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 2 ways ¾” C322N10_* Modular manifold with shut-off valve, size 1”, connection ½”, 2 ways 1” C322N12_* Modular manifold with shut-off valve, size 1”, connection ¾” EK, 2 ways 1” C32200_*35 Modular manifold with shut-off valve, size ¾”, connection ½”, 2 ways, outlet centres 35 mm ¾” C32210_*35 Modular manifold with shut-off valve, size 1”, connection ½”, 2 ways, outlet centres 35 mm 1” C323N00_* Modular manifold with shut-off valve, size ¾”, connection ½”, 3 ways ¾” C323N02_* Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 3 ways ¾” C323N10_* Modular manifold with shut-off valve, size 1”, connection ½”, 3 ways 1” C323N12_* Modular manifold with shut-off valve, size 1”, connection ¾” EK, 3 ways 1” C32300_*35 Modular manifold with shut-off valve, size ¾”, connection ½”, 3 ways, outlet centres 35 mm ¾” C32310_*35 Modular manifold with shut-off valve, size 1”, connection ½”, 3 ways, outlet centres 35 mm 1” C324N00_* Modular manifold with shut-off valve, size ¾”, connection ½”, 4 ways ¾” C324N02_* Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 4 ways ¾” C324N10_* Modular manifold with shut-off valve, size 1”, connection ½”, 4 ways 1” C324N12_* Modular manifold with shut-off valve, size 1”, connection ¾” EK, 4 ways 1” C32400_*35 Modular manifold with shut-off valve, size ¾”, connection ½”, 4 ways, outlet centres 35 mm ¾” C32410_*35 Modular manifold with shut-off valve, size 1”, connection ½”, 4 ways, outlet centres 35 mm 1” C325N00_* Modular manifold with shut-off valve, size ¾”, connection ½”, 5 ways ¾” C325N02_* Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 5 ways ¾” C325N10_* Modular manifold with shut-off valve, size 1”, connection ½”, 5 ways 1” C325N12_* Modular manifold with shut-off valve, size 1”, connection ¾” EK, 5 ways 1” C32500_*35 Modular manifold with shut-off valve, size ¾”, connection ½”, 5 ways, outlet centres 35 mm ¾” C322N00_*OR Modular manifold with shut-off valve, size ¾”, connection ½”, 2 ways ¾” C322N02_*OR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 2 ways ¾” C322N10_*OR Modular manifold with shut-off valve, size 1”, connection ½”, 2 ways 1” C322N12_*OR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 2 ways 1” C322N00_*50OR Modular manifold with shut-off valve, size ¾”, connection ½”, 2 ways, outlet centres 50 mm ¾” C322N02_*50OR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 2 ways, outlet centres 50 mm ¾” C322N10_*50OR Modular manifold with shut-off valve, size 1”, connection ½”, 2 ways, outlet centres 50 mm 1” C322N12_*50OR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 2 ways, outlet centres 50 mm 1” C323N00_*OR Modular manifold with shut-off valve, size ¾”, connection ½”, 3 ways ¾” C323N02_*OR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 3 ways ¾” C323N10_*OR Modular manifold with shut-off valve, size 1”, connection ½”, 3 ways 1” C323N12_*OR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 3 ways 1” C323N00_*50OR Modular manifold with shut-off valve, size ¾”, connection ½”, 3 ways, outlet centres 50 mm ¾” C323N02_*50OR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 3 ways, outlet centres 50 mm ¾” C323N10_*50OR Modular manifold with shut-off valve, size 1”, connection ½”, 3 ways, outlet centres 50 mm 1” C323N12_*50OR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 3 ways, outlet centres 50 mm 1” C324N00_*OR Modular manifold with shut-off valve, size ¾”, connection ½”, 4 ways ¾” C324N02_*OR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 4 ways ¾” C324N10_*OR Modular manifold with shut-off valve, size 1”, connection ½”, 4 ways 1” C324N12_*OR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 4 ways 1” C324N00_*50OR Modular manifold with shut-off valve, size ¾”, connection ½”, 4 ways, outlet centres 50 mm ¾” C324N02_*50OR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 4 ways, outlet centres 50 mm ¾” C324N10_*50OR Modular manifold with shut-off valve, size 1”, connection ½”, 4 ways, outlet centres 50 mm 1” C324N12_*50OR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 4 ways, outlet centres 50 mm 1” C325N00_*OR Modular manifold with shut-off valve, size ¾”, connection ½”, 5 ways ¾” C325N02_*OR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 5 ways ¾” C325N10_*OR Modular manifold with shut-off valve, size 1”, connection ½”, 5 ways 1” C325N12_*OR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 5 ways 1” C522N00_V Modular manifold with shut-off valve, size ¾”, connection ½”, 2 ways ¾” C522N02_V Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 2 ways ¾” C522N10_V Modular manifold with shut-off valve, size 1”, connection ½”, 2 ways 1” C522N12_V Modular manifold with shut-off valve, size 1”, connection ¾” EK, 2 ways 1” C523N00_V Modular manifold with shut-off valve, size ¾”, connection ½”, 3 ways ¾” C523N02_V Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 3 ways ¾” C523N10_V Modular manifold with shut-off valve, size 1”, connection ½”, 3 ways 1” C523N12_V Modular manifold with shut-off valve, size 1”, connection ¾” EK, 3 ways 1” C524N00_V Modular manifold with shut-off valve, size ¾”, connection ½”, 4 ways ¾” C524N02_V Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 4 ways ¾” C524N10_V Modular manifold with shut-off valve, size 1”, connection ½”, 4 ways 1” C524N12_V Modular manifold with shut-off valve, size 1”, connection ¾” EK, 4 ways 1” C525N00_V Modular manifold with shut-off valve, size ¾”, connection ½”, 5 ways ¾” C525N02_V Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 5 ways ¾” C525N10_V Modular manifold with shut-off valve, size 1”, connection ½”, 5 ways 1” C525N12_V Modular manifold with shut-off valve, size 1”, connection ¾” EK, 5 ways 1” C522N00_VOR Modular manifold with shut-off valve, size ¾”, connection ½”, 2 ways ¾” C522N02_VOR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 2 ways ¾” C522N10_VOR Modular manifold with shut-off valve, size 1”, connection ½”, 2 ways 1” C522N12_VOR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 2 ways 1” C522N00_V50OR Modular manifold with shut-off valve, size ¾”, connection ½”, 2 ways, outlet centres 50 mm ¾” C522N02_V50OR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 2 ways, outlet centres 50 mm ¾” C522N10_V50OR Modular manifold with shut-off valve, size 1”, connection ½”, 2 ways, outlet centres 50 mm 1” C522N12_V50OR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 2 ways, outlet centres 50 mm 1” C523N00_VOR Modular manifold with shut-off valve, size ¾”, connection ½”, 3 ways ¾” C523N02_VOR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 3 ways ¾” C523N10_VOR Modular manifold with shut-off valve, size 1”, connection ½”, 3 ways 1” C523N12_VOR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 3 ways 1” C523N00_V50OR Modular manifold with shut-off valve, size ¾”, connection ½”, 3 ways, outlet centres 50 mm ¾” C523N02_V50OR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 3 ways, outlet centres 50 mm ¾” C523N10_V50OR Modular manifold with shut-off valve, size 1”, connection ½”, 3 ways, outlet centres 50 mm 1” C523N12_V50OR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 3 ways, outlet centres 50 mm 1” C524N00_VOR Modular manifold with shut-off valve, size ¾”, connection ½”, 4 ways ¾” C524N02_VOR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 4 ways ¾” C524N10_VOR Modular manifold with shut-off valve, size 1”, connection ½”, 4 ways 1” C524N12_VOR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 4 ways 1” C524N00_V50OR Modular manifold with shut-off valve, size ¾”, connection ½”, 4 ways, outlet centres 50 mm ¾” C524N02_V50OR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 4 ways, outlet centres 50 mm ¾” C524N10_V50OR Modular manifold with shut-off valve, size 1”, connection ½”, 4 ways, outlet centres 50 mm 1” C524N12_V50OR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 4 ways, outlet centres 50 mm 1” C525N00_VOR Modular manifold with shut-off valve, size ¾”, connection ½”, 5 ways ¾” C525N02_VOR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 5 ways ¾” C525N10_VOR Modular manifold with shut-off valve, size 1”, connection ½”, 5 ways 1” C525N12_VOR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 5 ways 1” C532N00_BI Modular manifold with shut-off valve, size ¾”, connection ½”, 2 ways ¾” C532N02_BI Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 2 ways ¾” C532N10_BI Modular manifold with shut-off valve, size 1”, connection ½”, 2 ways 1” C532N12_BI Modular manifold with shut-off valve, size 1”, connection ¾” EK, 2 ways 1” C533N00_BI Modular manifold with shut-off valve, size ¾”, connection ½”, 3 ways ¾” C533N02_BI Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 3 ways ¾” C533N10_BI Modular manifold with shut-off valve, size 1”, connection ½”, 3 ways 1” C533N12_BI Modular manifold with shut-off valve, size 1”, connection ¾” EK, 3 ways 1” C534N00_BI Modular manifold with shut-off valve, size ¾”, connection ½”, 4 ways ¾” C534N02_BI Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 4 ways ¾” C534N10_BI Modular manifold with shut-off valve, size 1”, connection ½”, 4 ways 1” C534N12_BI Modular manifold with shut-off valve, size 1”, connection ¾” EK, 4 ways 1” C535N00_BI Modular manifold with shut-off valve, size ¾”, connection ½”, 5 ways ¾” C535N02_BI Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 5 ways ¾” C535N10_BI Modular manifold with shut-off valve, size 1”, connection ½”, 5 ways 1” C535N12_BI Modular manifold with shut-off valve, size 1”, connection ¾” EK, 5 ways 1” C532N00_BIOR Modular manifold with shut-off valve, size ¾”, connection ½”, 2 ways ¾” C532N02_BIOR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 2 ways ¾” C532N10_BIOR Modular manifold with shut-off valve, size 1”, connection ½”, 2 ways 1” C532N12_BIOR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 2 ways 1” C532N00_BI50OR Modular manifold with shut-off valve, size ¾”, connection ½”, 2 ways, outlet centres 50 mm ¾” C532N02_BI50OR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 2 ways, outlet centres 50 mm ¾” C532N10_BI50OR Modular manifold with shut-off valve, size 1”, connection ½”, 2 ways, outlet centres 50 mm 1” C532N12_BI50OR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 2 ways, outlet centres 50 mm 1” C533N00_BIOR Modular manifold with shut-off valve, size ¾”, connection ½”, 3 ways ¾” C533N02_BIOR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 3 ways ¾” C533N10_BIOR Modular manifold with shut-off valve, size 1”, connection ½”, 3 ways 1” C533N12_BIOR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 3 ways 1” C533N00_BI50OR Modular manifold with shut-off valve, size ¾”, connection ½”, 3 ways, outlet centres 50 mm ¾” C533N02_BI50OR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 3 ways, outlet centres 50 mm ¾” C533N10_BI50OR Modular manifold with shut-off valve, size 1”, connection ½”, 3 ways, outlet centres 50 mm 1” C533N12_BI50OR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 3 ways, outlet centres 50 mm 1” C534N00_BIOR Modular manifold with shut-off valve, size ¾”, connection ½”, 4 ways ¾” C534N02_BIOR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 4 ways ¾” C534N10_BIOR Modular manifold with shut-off valve, size 1”, connection ½”, 4 ways 1” C534N12_BIOR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 4 ways 1” C534N00_BI50OR Modular manifold with shut-off valve, size ¾”, connection ½”, 4 ways, outlet centres 50 mm ¾” C534N02_BI50OR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 4 ways, outlet centres 50 mm ¾” C534N10_BI50OR Modular manifold with shut-off valve, size 1”, connection ½”, 4 ways, outlet centres 50 mm 1” C534N12_BI50OR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 4 ways, outlet centres 50 mm 1” C535N00_BIOR Modular manifold with shut-off valve, size ¾”, connection ½”, 5 ways ¾” C535N02_BIOR Modular manifold with shut-off valve, size ¾”, connection ¾” EK, 5 ways ¾” C535N10_BIOR Modular manifold with shut-off valve, size 1”, connection ½”, 5 ways 1” C535N12_BIOR Modular manifold with shut-off valve, size 1”, connection ¾” EK, 5 ways 1” Where: 1st (letter): C = Manifold. 2nd and 3rd (numbers): 32 or 52 or 53 = series designation (32-52-53). 4th (number): from 2 to 5 = number of outlet ways (2 to 5). 5th (letter): N = New version. 6th (number): 0 or 1 = 0: Body size ¾”, 1: Body size 1”. 7th (number): 0 or 2 = 0:Outlet connection ½”, 2: Outlet connection ¾” EK. 8th (letter): _ Finish variant, T= yellow - Z= nickel-plated. 9th and eventual 10th (letter) * Handle variant: R= red (only for C320 and C320-OR family), B=blue (only for C320 and C320-OR family), V = green (for C520 and C520-OR family only), BI = White (for C530 and C530-OR family only). Followings 2 digits: 35 or 50. 35 = outlet centres 35mm. 50 = outlet centres 50mm. (blank space) = outlet centres 40mm. Further followings 2 letters: OR = Variant with o-ring seal. (blank space) = without o-ring seal. EK = Eurocone type connection.

Manufacturer:
Carlo Poletti S.r.l
Company Name
Carlo Poletti S.r.l
Address
Via Tancognino 134 28024 Gozzano
Country
Italy
Phone
+39 0322 94752

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 392 of 468

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.