#2305544

'Akfix PS253 Pipe Sealant Medium Strength'. Blue coloured pipe sealant. Apply as per manufacturer's TDS 'Rev.01', issue date '23/10/2019'. Cure for 24 hours@23°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.

Section:
5510 Sealants - Screwed Joints
Section Subtitle:
General.
WRAS Approval Number:
2305544
Expiry date:
31/05/2028

Approval Holder:
Akkim Yapı Kimyasallari San. ve Tic. A.S.
Company Name
Akkim Yapı Kimyasallari San. ve Tic. A.S.
Address
Yeşilbayır, Şimşir Sk. No:22, 34555 Arnavutköy, Istanbul
Country
Turkey

View All Listings by this Company

Print This Approval


#2305324

Range of wall mounted, electronically operated combination tap assembly (chrome plated brass body). The flow is controlled by a solenoid valve which is actuated via an infrared sensor. The spout outlets incorporate a plastic aerator. The solenoid valve inlet incorporates a plastic and stainless steel filter. The products are supplied with a triple layered connecting hose (PVC inner and outer layer and nylon braided middle layer). Maximum working pressure 8.0 bar.

Non-metallic materials and components comply with BS6920 at 60°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
2305324
Note:
R008 applies to the solenoid and solenoid housing.
Size:
½” BSP (M)
Marking:
DTC28 & DEVA on body
Installation Requirements:
R001 R007 R008 R010
Expiry date:
31/05/2028
Model:
SENSOR9/W

Approval Holder:
Methven UK Limited
Company Name
Methven UK Limited
Address
Methven Experience Centre 3-3A Stone Cross Court Yew Tree Way Golborne Warrington
Postcode
WA3 3JE
Country
United Kingdom
Phone
0800 195 1602
General Email
raluca.olariu@uk.methven.com

View All Listings by this Company
Manufacturer:
Methven UK Limited
Company Name
Methven UK Limited
Address
Methven Experience Centre 3-3A Stone Cross Court Yew Tree Way Golborne Warrington
Postcode
WA3 3JE
Country
United Kingdom
Phone
0800 195 1602
General Email
raluca.olariu@uk.methven.com

View All Listings by this Company

Print This Approval


#2206068

Bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water only

Section:
2075 Float Operated Inlet Valve
Section Subtitle:
Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
WRAS Approval Number:
2206068
Size:
½” BSP (M)
Marking:
Ideal Standard, Model number and BS1212-4 on body
Installation Requirements:
R001 R550 R560 R562
Expiry date:
30/06/2027
Model:
EEM90030079, EEM83250067 & EV97967 F

Approval Holder:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT
Country
United Kingdom
General Email
tyeomans@idealstandard.co.uk

View All Listings by this Company

Print This Approval


#2306040

Range of Concealed WC dual flushing cistern with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly. Maximum working pressure -10 Bar Maximum operating temperature - cold water use only Models T1910 & T1911 can now incorporate a T8702 flush valve. Maximum working pressure 10 Bar, cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2306040
Size:
½” BSP (M)
Marking:
Bestter, Model number and Wras on Front of support bracket inside of cistern. 6 litre mark inside cistern
Installation Requirements:
R001 R556 R581
Expiry date:
30/06/2028
Model:
T1910 T1911

Approval Holder:
Bestter(Xiamen) Technology lnc.
Company Name
Bestter(Xiamen) Technology lnc.
Address
No.601, Tonghong Road, Tong'an Park Tong'an Industrial Zone, Xiamen City , China

View All Listings by this Company
Manufacturer:
Bestter(Xiamen) Technology lnc.
Company Name
Bestter(Xiamen) Technology lnc.
Address
No.601, Tonghong Road, Tong'an Park Tong'an Industrial Zone, Xiamen City , China

View All Listings by this Company

Print This Approval


#2306078

Range of concealed WC dual flushing cisterns with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10 Bar, cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2306078
Size:
½” BSP (M)
Marking:
VADO, WRAS & Model number on Front cover. 6 litre mark inside cistern.
Installation Requirements:
R001 R556 R581
Expiry date:
30/06/2028
Model:
WG-095S-F/C/VADO & WG-095S-C/VADO

Approval Holder:
VADO
Company Name
VADO
Address
Cheddar Business Park Wedmore Road Cheddar Somerset
Postcode
BS27 3EB
Country
United Kingdom
Phone
01934 745895
General Email
tom.ross@vado.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 328 of 890

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.