#2103041

Ultraflow ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103041
Note:
Expansion vessels should be installed in the vertical orientation and located so that the length of the connecting pipework is kept to a minimum.
Size:
22mm compression (Inlet Manifold)
Marking:
Ultraflow on front, technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/03/2026
Proviso:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°c.
Model:
UD90 - ULTRAFLOW 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD120 - ULTRAFLOW 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UD150 – ULTRAFLOW 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD170 – ULTRAFLOW 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UD200 – ULTRAFLOW 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD250 – ULTRAFLOW 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UD300 – ULTRAFLOW 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UI90-ULTRAFLOW 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI120 - ULTRAFLOW 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI150 - ULTRAFLOW 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI170 - ULTRAFLOW 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI200 - ULTRAFLOW 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI250 - ULTRAFLOW 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UI300 - ULTRAFLOW 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UWD170 -ULTRAFLOW 170 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWD200 -ULTRAFLOW 200 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWD250 -ULTRAFLOW 250 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWD300 -ULTRAFLOW 300 INDIRECT SOLAR SINGLE COIL UNVENTED HOT WATER STORAGE CYLINDER UWI170 ULTRAFLOW 170 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UWI200 ULTRAFLOW 200 NDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UWI250 ULTRAFLOW 250 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UWI300 ULTRAFLOW 300 INDIRECT SOLAR TWIN COIL UNVENTED HOT WATER STORAGE CYLINDER UDS60-ULTRAFLOW SLIM 60 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UDS90-ULTRAFLOW SLIM 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS120-ULTRAFLOW SLIM 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS150D-ULTRAFLOW SLIM 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS170D-ULTRAFLOW SLIM 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UDS200D-ULTRAFLOW SLIM 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UIS60-ULTRAFLOW SLIM 60 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS90-ULTRAFLOW SLIM 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS120-ULTRAFLOW SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS150-ULTRAFLOW SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS170-ULTRAFLOW SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UIS200-ULTRAFLOW SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER

Approval Holder:
L & M (HEATING) SUPPLIES LTD.
Company Name
L & M (HEATING) SUPPLIES LTD.
Address
103 LOCKFIELD AVENUE ENFIELD, ENFIELD, MIDDLESEX
Postcode
EN3 7PY

View All Listings by this Company

Print This Approval


#2201107

Range of Ultraflow Air bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added January 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
1890 Unvented Heating Apparatus
Size:
Secondary circuit: 22mm compression. Primary circuit: 22mm compression. Return circuit: 22mm compression.
Marking:
Ultraflow Air on label on front of body.
Installation Requirements:
R001 R140 R360
Expiry date:
31/01/2027
Model:
UOD120 – ULTRAFLOW AIR 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UOD150 – ULTRAFLOW AIR 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UOD170 – ULTRAFLOW AIR 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UOD200 – ULTRAFLOW AIR 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UOD250 – ULTRAFLOWAIR 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UOD300 – ULTRAFLOW AIR 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI120 – ULTRAFLOW AIR 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI150 – ULTRAFLOW AIR 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI170 – ULTRAFLOW AIR 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI200 – ULTRAFLOW AIR 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI250 – ULTRAFLOW AIR 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOI300 - ULTRAFLOW AIR 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UODS120-ULTRAFLOW AIR SLIM 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UODS150-ULTRAFLOW AIR SLIM 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UODS170-ULTRAFLOW AIR SLIM 170 DIRECT UNVENTED HOT WATER STORAGE CYLINDER UODS200-ULTRAFLOW AIR SLIM 200 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. UOIS120-ULTRAFLOW AIR SLIM 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOIS150-ULTRAFLOW AIR SLIM 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOIS170-ULTRAFLOW AIR SLIM 170 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER UOIS200-ULTRAFLOW AIR SLIM 200 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER

Approval Holder:
L & M (HEATING) SUPPLIES LTD.
Company Name
L & M (HEATING) SUPPLIES LTD.
Address
103 LOCKFIELD AVENUE ENFIELD, ENFIELD, MIDDLESEX
Postcode
EN3 7PY

View All Listings by this Company

Print This Approval


#241204001

Range of air release valves with plastic bodies, EPDM ‘O’ rings and polypropylene floats. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1980 Valves
Section Subtitle:
Air venting. Fittings in this section are suitable for above ground installations only.
WRAS Approval Number:
241204001
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
see model
Marking:
Bermad on body. Size, model, PN, DN, date of manufacture (MM/YYYY) on adhesive label on body.
Installation Requirements:
R001 R535
Expiry date:
31/12/2029
Model:
A30-3/4”: ¾” BSP (M). A30-1”: 1” BSP (M). C30-3/4”: ¾” BSP (M). C30-1”: 1” BSP (M). C30-2”: 2” BSP (M).

Approval Holder:
Bermad CS Ltd
Company Name
Bermad CS Ltd
Address
Kibbutz Evron 2280800, Israel

View All Listings by this Company
Manufacturer:
Bermad CS Ltd
Company Name
Bermad CS Ltd
Address
Kibbutz Evron 2280800, Israel

View All Listings by this Company

Print This Approval


#240504023

Range of automatic air venting valves with plastic bodies and EPDM ‘O’-rings. Maximum working pressure 6.0 bar. Maximum operating temperature 99°C.

Section:
1980 Valves
Section Subtitle:
Air venting. Fittings in this section are suitable for above ground installations only.
WRAS Approval Number:
240504023
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
For close circuit use only.
Size:
See models.
Marking:
Caleffi logo moulded on cap.
Installation Requirements:
R001 R200
Expiry date:
31/05/2029
Model:
49513: 20.9mm pushfit manifold, C502433 CST: ⅜” BSP (M), C502600 CST: 19.9mm pushfit manifold, C502601 CST: 20.9mm pushfit manifold, C502604 PLY: 17.7mm pushfit manifold, C502630 CST: ⅜” BSP (M), C502631 CST: ⅜” BSP (M), C502633 CST: ⅜” BSP (M), C502640 CST: ½” BSP (M), C502644 CST: ½” BSP (M), C502634 CST: ⅜” BSP (M).
Product Images

Approval Holder:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company
Manufacturer:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company

Print This Approval


#240702040

Range of wall mounted, thermostatic shower valves (chromium plated brass) incorporating a single sequential headwork controlling both flow and temperature with a single lever operating member. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection The product is supplied with an isolation valve for each inlet. Maximum working pressure; 10 Bar Maximum operating temperature 85°C

Section:
2010 Shower Valves
Section Subtitle:
Shower valve(s) with thermostatic temperature control
WRAS Approval Number:
240702040
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1/2" BSP (M)
Marking:
Armitage Shanks on body.
Installation Requirements:
R001 R010 R040
Expiry date:
31/07/2029
Model:
A4130AA - Contour 21
Product Images

Approval Holder:
Armitage Shanks
Company Name
Armitage Shanks
Address
Old Road (Lodge 1), Armitage, Rugeley
Postcode
WS15 4BT
Country
Staffordshire,
Phone
+44 800 866 966 Fax: 01543 491677 Telex: 339781

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 302 of 436

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.