Directory Search Results

Print List

#241002020

Range of two-way manual diverter valves with shut-off position. Products are for insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.

Section:
2050 Diverter
Section Subtitle:
Diverter cartridge(s) with manual adjustment.
WRAS Approval Number:
241002020
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
26mm O.D.
Marking:
HG on body
Installation Requirements:
R001
Expiry date:
31/10/2029
Model:
30079500 & 30650210

Approval Holder:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company

Print This Approval


#241002007

Range of regulating and shut-off valves with brass bodies and EPDM ‘O’-Rings. Maximum working pressure 16.0 Bar for BSP (M) and 25.0 bar for BSP (F). Maximum operating temperature 85.0°C

Section:
2170 Valves
Section Subtitle:
Flow control, manually operated.
WRAS Approval Number:
241002007
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Male thread DN15 – DN 50 Female thread DN15 – DN50
Marking:
Oventrop logo, flow arrow, PN and DN on body. Oventrop, product name and DN on face plate.
Installation Requirements:
R001
Expiry date:
31/10/2029
Model:
HydroControl V Double regulating valve, female thread 1062404 - DN15 1062406 - DN20 1062408 - DN25 1062410 - DN32 1062412 - DN40 1062416 - DN50 HydroControl V Double regulating valve, male thread 1062604 - DN15 1062606 - DN20 1062608 - DN25 1062610 - DN32 1062612 - DN40 1062616 - DN50 HydroControl A Shutoff valve, female thread, 1067524 - DN15 1067526 - DN20 1067528 - DN25 1067530 - DN32 1067532 - DN40 1067536 - DN50 HydroControl A Shutoff valve, male thread, 1067624 - DN15 1067626 - DN20 1067628 - DN25 1067630 - DN32 1067632 - DN40 1067636 - DN50 HydroControl M Double regulating valve with metering station, female thread 1065844 - DN15 ULF 1065834 - DN15 LF 1065824 - DN15 MF 1065804 - DN15 1065806 - DN20 1065808 - DN25 1065810 - DN32 1065812 - DN40 1065816 - DN50

Manufacturer:
Oventrop GmbH & Co KG
Company Name
Oventrop GmbH & Co KG
Address
Paul-Oventrop-Strasse 1, 59939 Olsberg
Country
Germany

View All Listings by this Company

Print This Approval


#240402719

Range of globe type spring loaded, resilient trim, non-return valves with epoxy coated ductile iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. Therefore, not considered suitable for Backflow Protection.
WRAS Approval Number:
240402719
Size:
DN40 to DN400
Marking:
Crane, model, size, PN and product info on data plate on body. DN, PN, material of body, flow arrow on valve body.
Installation Requirements:
R001
Expiry date:
30/04/2029
Model:
D130W (DN50 – DN300)

Approval Holder:
Crane Ltd
Company Name
Crane Ltd
Address
Crane House, Epsilon Terrace, West Road, Ipswich
Postcode
IP3 9FJ
Country
United Kingdom
Phone
01473 277 364
General Email
tturner@cranebsu.com

View All Listings by this Company

Print This Approval


#240402720

Range of globe type spring loaded, resilient trim, non-return valves with epoxy coated ductile iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. Therefore, not considered suitable for Backflow Protection.
WRAS Approval Number:
240402720
Size:
DN40 to DN400
Marking:
Hattersley, model, size, PN and product info on data plate on body. DN, PN, material of body, flow arrow on valve body.
Installation Requirements:
R001
Expiry date:
30/04/2029
Model:
Fig 160W (DN50 – DN300)

Approval Holder:
Hattersley
Company Name
Hattersley
Address
11-15 Epsilon Terrace West Road Ipswich Suffolk
Postcode
IP3 9FJ
Country
United Kingdom
Phone
0766465023
General Email
tturner@cranebsu.com

View All Listings by this Company

Print This Approval


#240902714

Range of swing gate, non-return valves with (blue or red epoxy powder coated) ductile iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. Therefore, not considered suitable for Backflow Protection.
WRAS Approval Number:
240902714
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DN50 – 300 flanged
Marking:
Rapidrop, PN, DN, date of manufacture (YYYY), flow arrow and technical information data plate on body.
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
FIG 302

Approval Holder:
Rapidrop Global Limited
Company Name
Rapidrop Global Limited
Address
Rutland Business Park Newark Road Peterborough
Postcode
PE1 5WA
Country
United Kingdom
Phone
01733 847543
General Email
craig.galloway@rapidrop.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 276 of 451

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.