Directory Search Results

Print List

#2311062

Range of plate heat exchangers with stainless steel plate bodies and copper brazing. Maximum working pressure: 45 Bar. Maximum operating temperature: 99 °C.

Section:
1350 Heat Exchangers
Size:
See models.
Marking:
Hrale logo, Model, pressure and product info on adhesive label.
Installation Requirements:
R001
Expiry date:
30/11/2028
Model:
B3-5, B3-6, B3-9 - ¼” BSP (F) or ⅜” welded pipe connections. B3-12, B3-13, B3-14, B3-15, B3-23, B3-36 & B3-42 - ¾” BSP (M) or 7/8” welded pipe connections. B3-14 DW, B3-16, B3-18 & B3-20 - 1” BSP (M) or 7/8” welded pipe connection. B3-26, B3-27, B3-52, B3-52 DW, B3-60, B3-40, B3-68 & B3-80 - 1 ¼” BSP (M) or 1 ⅜” welded pipe connections. B3-32, B3-32 DW & B3-35 - 1” BSP (M) or 1 1/8” welded pipe connections. B3-63, B3-95, B3-95 DW, B3-115 – 2 ½” BSP (M) or 2 ⅜” welded pipe connections. B3-105 – 3” BSP (M) or 3” welded pipe connections. B3-30 – 1” BSP (M) or 1” welded pipe connections.
Product Images

Approval Holder:
Ningbo Hrale Plate Heat Exchanger Co., Ltd.
Company Name
Ningbo Hrale Plate Heat Exchanger Co., Ltd.
Address
No. 98, Binwan Road, Binhai New Area, Fenghua, Ningbo, China

View All Listings by this Company

Print This Approval


#2312347

Range of packaged plate heat exchangers comprising of stainless steel plates with EPDM gaskets. The products are supplied with twin primary circulation pumps, a secondary circulation pump, 3 port control valve and a control panel with full Mod BUS BMS connectivity. Maximum working pressure - Primary and Secondary circuits 10.0 bar. Maximum operating temperature 85°C.

Section:
1350 Heat Exchangers
Size:
25, 30, 35 and 38 Series: Primary circuit: 1¼” BSP (F) inlet x 1¼” BSP (M) outlet. Secondary circuit: 1¼” BSP (M) inlet x 1¼” BSP (F) outlet. 40 Series: Primary circuit: 1½” BSP (F) inlet x 1½” BSP (M) outlet. Secondary circuit: 1½” BSP (F) inlet x 1½” BSP (F) outlet. 50 Series: Primary circuit: 2” BSP (M) inlet/outlet. Secondary circuit: 2” BSP (F) inlet/outlet.
Marking:
CHWS logo on front of control unit. CHWS logo serial number and model number on label on back plate.
Installation Requirements:
R001
Expiry date:
31/12/2028
Model:
Propak Thermal range: 25 Series: 2507, 2509, 2511, 2513, 2515. 30 Series: 3013, 3017, 3019, 3021, 3023, 3025, 3029, 3033, 3039, 3045. 35 Series: 3531, 3535, 3539, 3543. 38 Series: 3811, 3821, 3829, 3835, 3843, 3851, 3859, 3867, 3875. 40 Series: 4015, 4017, 4019, 4021, 4029, 4035, 4041. 50 Series: 5021, 5025, 5031, 5035, 5039, 5043, 5049.

Approval Holder:
Commercial Hot Water Solutions Ltd.
Company Name
Commercial Hot Water Solutions Ltd.
Address
THe Hive, Beaufighter Road, Weston-Super-Mare
Postcode
BS24 8EE

View All Listings by this Company

Print This Approval


#2402803

Range of wall mounted, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel, pressure relief valve set at 3.0 bar and flow regulators. The inlets to both domestic hot water and primary circuits are controlled via screwdriver operated angled spherical valve. The primary circuit can be filled via a built in CAB device, that has been verified by test (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 80°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2402803
Note:
The discharge from the relief outlet port of the CAB device must be made via a type AA, AB or AD air gap, or in accordance with EN 1717. Claims of flow rate are made by the manufacturer and not considered part of the listing.
Size:
22mm Compression Primary 15mm Compression Secondary
Marking:
Worcester on label on the front panel. Serial number, model numbers and other technical information on adhesive labels on body and underside of the unit
Installation Requirements:
R001
Expiry date:
28/02/2029
Model:
Worcester Greenstar 8000 Style GR8700iW 30 C - Gas combi boiler 30kw, 14 plate heat exchanger 111/min, Worcester Greenstar 8000 Style GR8700iW 35 C - Gas combi boiler 35kw, 16 plate heat exchanger 131/min, Worcester Greenstar 8000 Style GR8700iW 40 C - Gas combi boiler 40kw, 18 plate heat exchanger 141/min, Worcester Greenstar 8000 Style GR8700iW 45 C - Gas combi boiler 45kw, 18 plate heat exchanger 151/min, Worcester Greenstar 8000 Style GR8700iW 50 C - Gas combi boiler 50kw, 20 plate heat exchanger 151/min. Worcester Greenstar 8000 Life GR8300iW 30 C - Gas combi boiler 30kw, 14 plate heat exchanger 111/min, Worcester Greenstar 8000 Life GR8300iW 35 C - Gas combi boiler 35kw, 16 plate heat exchanger 131/min, Worcester Greenstar 8000 Life GR8300iW 40 C - Gas combi boiler 40kw, 18 plate heat exchanger 141/min, Worcester Greenstar 8000 Life GR8300iW 45 C - Gas combi boiler 45kw, 18 plate heat exchanger 151/min, Worcester Greenstar 8000 Life GR8300iW 50 C - Gas combi boiler 50kw, 20 plate heat exchanger 151/min. Models added September 2024 Worcester Greenstar 8000+ GR8701iW 32 CB - Gas combi boiler 32kW, 16 plate heat exchanger 13 l/min Worcester Greenstar 8000+ GR8701iW 36 CB - Gas combi boiler 36kW, 16 plate heat exchanger 14 l/min Worcester Greenstar 8000+ GR8701iW 32 C - Gas combi boiler 32kW, 16 plate heat exchanger 13 l/min Worcester Greenstar 8000+ GR8701iW 36 C - Gas combi boiler 36kW, 16 plate heat exchanger 14 l/min Worcester Greenstar 8000+ GR8701iW 40 C - Gas combi boiler 40kW, 18 plate heat exchanger 15 l/min Worcester Greenstar 8000+ GR8701iW 45 C - Gas combi boiler 45kW, 18 plate heat exchanger 18 l/min Worcester Greenstar 8000+ GR8701iW 50 C - Gas combi boiler 50kW, 20 plate heat exchanger 21 l/min

Approval Holder:
Worcester Bosch
Company Name
Worcester Bosch
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
+44 1905 752761
General Email
ian.sharp@uk.bosch.com

View All Listings by this Company

Print This Approval


#2312904

Range of integrated water circuits with plastic bodies and EPDM ‘O’ rings and gaskets. The assemblies incorporate flow switches, plate heat exchangers and plastic flow regulators. The primary circuit incorporates a 3.0 bar rated pressure relief valve. Maximum working pressures: 2.5 bar primary circuit, 10.0 bar secondary circuit. Maximum operating temperature 85°C.

Section:
1478 Heater
Section Subtitle:
Combination boilers - accessories and components.
WRAS Approval Number:
2312904
Size:
Secondary circuit: ½” BSP (M) inlet x F4 outlet. Primary circuit: ¾” BSP (M) inlet and outlet connections.
Marking:
Grundfos and Grundfos logo on primary circuit pump.
Installation Requirements:
R001 R008
Expiry date:
31/12/2028
Model:
IWC ICHS UPS/UPM2/3/4-xx v.xxx-xxx Where: UPS, UPM2, UPM3, UPM4 = pump type (primary circuit). -xx = pump max. head (UPS: 50, 60, 70. UPM2: 60, 70. UPM3: 20, 40, 45, 50, 60, 70, 75. UPM4: 20, 30, 40, 45, 50, 55, 60, 65, 70, 75). v.xxx-xxx = version number-free text, and can be any alphanumerical characters.
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#2310392

Range of water meters with epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1505 Water Meters
Size:
DN250, DN300 flanged connections
Marking:
WESAN, size and flow arrow on body.
Installation Requirements:
R001
Expiry date:
31/10/2028
Model:
WESAN WP DN250 & WESAN WP DN300 X = DN size of the water meter YYY can then be replaced with any of the following: ‘-‘: basic type with mechanical counter NK: mechanical counter with contact impulse transducer NKO: mechanical counter with contact and optical impulse transducer NKP: advance prepared counter for contact transducer NO: mechanical counter with optical impulse transducer NOP: advance prepared counter to optical impulse transducer NKOP: counter for contact and optical impulse transducer prepared in advance G: threaded coupling (only for DN50) GH: with storz coupling (only for DN50) 08: version with IP68 cover

Approval Holder:
Diehl Metering GmbH
Company Name
Diehl Metering GmbH
Address
Industriestraße 13 91522 Ansbach
Country
Germany

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 244 of 431

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.