Pumps

Section Code 1610 : Wholesome water use.

Back To Directory Sections

#2311069

Range of vertical multistage pumps with either stainless-steel bodies or cast-iron bodies with a black epoxy powder coating, stainless-steel impellers, shaft and outer sleeve, EPDM ‘O’-rings and a silicon carbide + EPDM shaft seal. Maximum working pressure 25.0 bar. Maximum operating temperature 90°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2311069
Size:
DN25 -100.
Marking:
Capari logo on metal cover plate on side of body. Flow arrow on body. Type, model, pressure and other information on data plate on body.
Installation Requirements:
R001 R415
Expiry date:
30/11/2028
Model:
CVX AAB/CC-D/E Series: CVX. AA: Pump model size representing flow rate (m³/h) - 03, 05, 10, 15, 20, 32, 45, 64, 90. B: Pump generational code - 1. CC: No. of stages (model dependent - see below). D: Frequency - V = 50Hz or W = 50/60Hz. /G = cast iron base (CVX451/641/901 models only). Stainless steel bodies: CVX031: 5 -36 stages. 691472 - CVX031/5-V (DN25), 691473 - CVX031/7-V (DN25), 691474 - CVX031/10-V (DN25), 691475 - CVX031/15-V (DN25), 691476 - CVX031/19-V (DN25), 691477 - CVX031/23-V (DN25), 691478 - CVX031/29-V (DN25), 691479 - CVX031/33-V (DN25), 691480 - CVX031/36-V (DN25). CVX051: 4-36 stages. 691482 - CVX051/4-V (DN25), 691483 - CVX051/5-V (DN25), 691484 - CVX051/8-V (DN25), 691485 - CVX051/10-V (DN25), 691486 - CVX051/13-V (DN25), 691487 - CVX051/16-V (DN25), 691488 - CVX051/20-V (DN25), 691489 - CVX051/24-V (DN25), 691490 - CVX051/29-V (DN25), 691491 - CVX051/36-V (DN25). CVX101: 3-22 stages. 691493 - CVX101/3-V (DN40), 691494 - CVX101/4-V (DN40), 691495 - CVX101/6-V (DN40), 691496 - CVX101/9-V (DN40), 691497 - CVX101/12-V (DN40), 691498 - CVX101/16-V (DN40), 691499 - CVX101/22-V (DN40). CVX151: 2-17 stages. 691501 - CVX151/2-V (DN50), 691502 - CVX151/3-V (DN50), 691503 - CVX151/5-V (DN50), 691504 - CVX151/7-V (DN50), 691505 - CVX151/9-V (DN50), 691506 - CVX151/12-W (DN50), 691507 - CVX151/14-V (DN50), 691508 - CVX151/17-V (DN50). CVX201: 2-17 stages. 691510 - CVX201/2-V (DN50), 691511 - CVX201/3-V (DN50), 691512 - CVX201/5-V (DN50), 691513 - CVX201/7-V (DN50), 691514 - CVX201/10-W (DN50), 691515 - CVX201/14-V (DN50), 691516 - CVX201/17-V (DN50). CVX321: 2-14 stages. 691518 - CVX321/2-V (DN65), 691519 - CVX321/3-V (DN65), 691520 - CVX321/4-V (DN65), 691521 - CVX321/6-W (DN65), 691522 - CVX321/8-V (DN65), 691523 - CVX321/10-V (DN65), 691524 - CVX321/12-V (DN65), 691525 - CVX321/14-V (DN65). Cast iron bodies: CVX451: 2-13 stages. 691533 - CVX451/2-V/G (DN80), 691534 - CVX451/3-V/G (DN80), 691535 - CVX451/4-V/G (DN80), 691536 - CVX451/5-2-V/G (DN80), 691537 - CVX451/6-2-V/G (DN80), 691872 - CVX451/6-V/G (DN80), 691538 - CVX451/9-2-V/G (DN80), 691873 - CVX451/10-V/G (DN80), 691874 - CVX451/13-2-V/G (DN80). CVX641: 2-8 stages. 691539 - CVX641/2-V/G (DN100), 691540 - CVX641/3-1-V/G (DN100), 691541 - CVX641/4-V/G (DN100), 691875 - CVX641/4-2-V/G (DN100), 691542 - CVX641/6-2-V/G (DN100), 691543 - CVX641/7-1-V/G (DN100), 691876 - CVX641/8-1-V/G (DN100). CVX901: 2-6 stages. 691544 - CVX901/2-V/G (DN100), 691545 - CVX901/3-V/G (DN100), 691877 - CVX901/3-2-V/G (DN100), 691546 - CVX901/4-V/G (DN100), 691547 - CVX901/5-V/G (DN100), 691878 - CVX901/6-V/G (DN100).
Product Images

Approval Holder:
Caprari S.p.A
Company Name
Caprari S.p.A
Address
Via Emilia, Ovest 900, 41123 Modena
Country
Italy

View All Listings by this Company

Print This Approval


#2312802

Range of cold water supply booster sets, incorporating stainless steel manifold system connecting 2 or 3 wholesome water pumps. The set also includes spherical valves, non-return valves (not intended or suitable for backflow protection) and expansion vessels. Maximum working pressure 10.0 bar. Cold water supply only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2312802
Size:
DN80 inlet x DN80 outlet flanged connections. DN50 inlet x DN65 outlet flanged connections.
Marking:
Dutypoint, model, serial number and technical information on adhesive label on base plate.
Installation Requirements:
R001 R415
Expiry date:
31/12/2028
Model:
DN50 Discharge Versions: Twin pump units: FR/VR2-03, FR/VR2-05, FR/VR2-10. Triple pump units: FR/VR3-03, FR/VR3-05, FR/VR3-10. DN80 Discharge Versions: Twin pump units: FR/VR2-15, FR/VR2-22. Triple pump units: FR/VR3-15, FR/VR3-22. The model is suffixed with two numbers to denote motor size and ‘LHT’.

Approval Holder:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Unit A, Quedgeley West Business Park, Hardwicke, Gloucester
Postcode
GL2 4PA
Country
United Kingdom
Phone
01452313334
General Email
austin.hill@dutypoint.com

View All Listings by this Company
Manufacturer:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Unit A, Quedgeley West Business Park, Hardwicke, Gloucester
Postcode
GL2 4PA
Country
United Kingdom
Phone
01452313334
General Email
austin.hill@dutypoint.com

View All Listings by this Company

Print This Approval


#2312902

‘SCALA1 TWIN’ range of booster pump sets, comprising of two pumps with plastic bodies, plastic impellers, EPDM and NBR ‘O’-rings and an accessory set consisting of a base plate, plastic manifold and four brass spherical valves. Each pump incorporates a non-return valve. Maximum working pressure 8.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2312902
Size:
1¼” BSP (F) manifold inlet/outlet.
Marking:
Pumps: Grundfos and Grundfos logo on body. Grundfos and Grundfos logo, model no., and other technical information on adhesive label on body. SCALA1 Twin accessory set: Grundfos logo, Grundfos, SCALA1 and SCALA2 on base plate. .
Installation Requirements:
R001 R415
Expiry date:
31/12/2028
Model:
SCALA1 TWIN 3-25, SCALA1 TWIN 3-35, SCALA1 TWIN 3-45, SCALA1 TWIN 5-25, SCALA1 TWIN 5-35, SCALA1 TWIN 5-55. Where 3 or 5 = flow rate in m³/h and 25-55 = max. head (m) on the individual pumps. The models are supplied with either of the following accessory sets: SCALA1 Twin accessory set (99725165), SCALA2 Twin accessory set (99743076).

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#240207701

‘SCALA 2’ integrated, self-priming, plastic bodied (compact) mains pressure boosting pump. Maximum working pressure 10.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240207701
Size:
1” BSPT (M) inlet and outlet.
Marking:
Grundfos and Grundfos logo on body. Grundfos and Grundfos logo, type, Model, P/N no., Serial no., P/C no., technical info, manufacturing country and data matrix on adhesive label on end of motor housing.
Installation Requirements:
R001 R415
Expiry date:
28/02/2029
Model:
Scala2 Model2 3-45 AKCCDE, Scala2 Model2 3-45 AKCDDE, Scala2 Model2 3-45 AKCGDE.
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#240507701

`UPM3` range of single stage circulator pumps, with stainless steel or plastic bodies, plastic impellers, ceramic shafts and bearings, EPDM 'O'-rings and seals. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240507701
Size:
Stainless steel body models (N): 1" BSP (M) (retrospectively added June 2024), 1½” BSP (M) & 2” BSP (M). Composite (plastic) body models (CIL3): 1” BSP (M).
Marking:
Grundfos logo, Grundfos and model on top of pump housing. Production number, serial number, and technical information on side of pump housing. Stainless steel models also have a flow arrow on the body.
Installation Requirements:
R001
Expiry date:
31/05/2029
Model:
UPM3 **1-**2 N ***3 (GFNxx-). UPM3 **1-**2 - CIL3 ***3 (GFNxx-). Model added November 2024: ALPHA SOLAR 25-**2 N 180. Where: UPM3 & ALPHA SOLAR = pump type. For UPM3 these can also be: UPM3 HYBRID, UMP3 DHW, UPM3 K, UPM3 AUTO L UPM3 FLEX AS. **1 = size of inlet/outlet connection: N models – 25 = 1 ½”, 32 = 2”. CIL3 models – 15 = 1”. **2 = maximum head (dm): 20, 40, 50, 60, 70, 75 (all models). 105, 145 (stainless steel body models only). N = stainless steel body. CIL3 = composite (plastic) body. ***3 = port to port length in mm: 130 (all models) or 180 (ALPHA SOLAR 1½” model and 2” N models only).
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 25 of 35

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.